{"title":"Inverters \u0026 Drives","description":null,"products":[{"product_id":"autonics-spb-a-series-din-rail-switching-mode-power-supplies","title":"Autonics SPB-A Series DIN Rail Switching Mode Power Supplies","description":"\u003cp class=\"ps-intro\"\u003eDIN-rail mount switching mode power supplies.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eWide lineup from 15 W to 480 W\u003c\/li\u003e\n\u003cli\u003ePFC circuit for improved power factor\u003c\/li\u003e\n\u003cli\u003eCompact size for maximum space efficiency\u003c\/li\u003e\n\u003cli\u003eOutput indicator (green LED) and low voltage indicator (red LED)\u003c\/li\u003e\n\u003cli\u003eOver-current, over-voltage, output short-circuit, and overheating protection\u003c\/li\u003e\n\u003cli\u003eWide ambient temperature range -20 to 70 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A015-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 15 W | 12 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A015-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 15 W | 24 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A030-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 30 W | 12 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A030-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 30 W | 24 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A060-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 60 W | 12 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A060-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 60 W | 24 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A120-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 120 W | 12 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A120-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 120 W | 24 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A240-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 240 W | 12 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A240-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 240 W | 24 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A240-48\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 240 W | 48 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A480-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 480 W | 24 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPB-A480-48\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPB-A Series | DIN-rail mount 480 W | 48 VDC output | AC-DC | 100-240 VAC | DIN-rail screw terminal | IP20 | DIN-rail SMPS PFC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395816390946,"sku":"AUTONICS-SPB-A-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1413.png?v=1790653203"},{"product_id":"autonics-spa-series-panel-mount-switching-mode-power-supplies","title":"Autonics SPA Series Panel Mount Switching Mode Power Supplies","description":"\u003cp class=\"ps-intro\"\u003ePanel mount switching mode power supplies. 30 W to 100 W output range. 5 VDC, 12 VDC, and 24 VDC output options.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eBuilt-in over-current protection, output short-circuit protection\u003c\/li\u003e\n\u003cli\u003eUniversal AC input 100-240 VAC\u003c\/li\u003e\n\u003cli\u003eCompact panel-mount form factor for control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-030-05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 30 W | 05 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-030-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 30 W | 12 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-030-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 30 W | 24 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-050-05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 50 W | 05 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-050-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 50 W | 12 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-050-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 50 W | 24 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-075-05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 75 W | 05 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-075-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 75 W | 12 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-075-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 75 W | 24 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-100-05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 100 W | 05 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-100-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 100 W | 12 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPA-100-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA Series | Panel mount 100 W | 24 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | panel mount SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395816489250,"sku":"AUTONICS-SPA-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1412.png?v=1790653204"},{"product_id":"autonics-spa-400-24-series-panel-mount-switching-mode-power-supplies","title":"Autonics SPA-400-24 Series Panel Mount Switching Mode Power Supplies","description":"\u003cp class=\"ps-intro\"\u003eHigh-power panel mount switching mode power supply. 400 W output at 24 VDC.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFor high-current industrial applications requiring stable 24 VDC bus\u003c\/li\u003e\n\u003cli\u003eUniversal AC input\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eSPA-400-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching mode power supply | SPA-400-24 Series | Panel mount 400 W | 24 VDC output | AC-DC | 100-240 VAC | Screw terminal | IP20 | high-power 400 W SMPS\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395816587554,"sku":"AUTONICS-SPA-400-24-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1415.png?v=1790653205"},{"product_id":"autonics-ais-series-2-phase-closed-loop-stepper-motor-system","title":"Autonics AiS Series 2-Phase Closed-Loop Stepper Motor System","description":"\u003cp class=\"ps-intro\"\u003eDC powered 2-phase closed-loop stepper motor systems with real-time position control.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eHigh speed and high torque drive without missing steps\u003c\/li\u003e\n\u003cli\u003eBuilt-in encoder feedback for closed-loop control\u003c\/li\u003e\n\u003cli\u003eEasy operation setting with external adjuster (Gain, Speed filter, In-position, Resolution)\u003c\/li\u003e\n\u003cli\u003eSupports motor frames Ø 20\/28\/35 mm and □ 42\/56\/60 mm\u003c\/li\u003e\n\u003cli\u003eBuilt-in brake type motors available (AiS-D-B Series). 24 VDC input\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | Ø 20 mm motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-28B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | Ø 28 mm motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-35B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | Ø 35 mm motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-42SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 42 mm S length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-42MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 42 mm M length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-42LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 42 mm L length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 56 mm S length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 56 mm M length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 56 mm L length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 60 mm S length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 60 mm M length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiS-D-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiS Series | DC closed-loop driver | □ 60 mm L length motor support | Pulse train + alarm output | 24 VDC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817308450,"sku":"AUTONICS-AiS-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1441.png?v=1790653212"},{"product_id":"autonics-aisa-series-ac-power-input-2-phase-closed-loop-stepper-motor-system","title":"Autonics AiSA Series AC Power Input 2-Phase Closed-Loop Stepper Motor System","description":"\u003cp class=\"ps-intro\"\u003eAC powered 2-phase closed-loop stepper motor systems for higher torque applications.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDirect connection to 100-240 VAC mains eliminates need for separate DC power supply\u003c\/li\u003e\n\u003cli\u003eSame closed-loop control features as AiS Series\u003c\/li\u003e\n\u003cli\u003eSupports motor frames □ 56\/60\/85 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 56 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 56 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 56 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 60 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 60 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 60 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-85SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 85 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-85MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 85 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiSA-D-85LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiSA Series | AC closed-loop driver | □ 85 mm motor | Pulse train + alarm output | 100-240 VAC | Screw terminal | IP20 | AC powered closed-loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817341218,"sku":"AUTONICS-AiSA-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1440.png?v=1790653213"},{"product_id":"autonics-aic-series-2-phase-closed-loop-stepper-motor-system-with-integrated-controller","title":"Autonics AiC Series 2-Phase Closed-Loop Stepper Motor System with Integrated Controller","description":"\u003cp class=\"ps-intro\"\u003eDC powered 2-phase closed-loop stepper systems with integrated motion controller.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eEliminates need for separate motion controller\u003c\/li\u003e\n\u003cli\u003eProgrammable motion sequences\u003c\/li\u003e\n\u003cli\u003eModbus RTU communication and digital I\/O\u003c\/li\u003e\n\u003cli\u003eSame motor frame support as AiS Series\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 20A motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-28B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 28B motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-35B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 35B motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-42SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 42SA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-42MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 42MA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-42LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 42LA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 56SA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 56MA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 56LA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 60SA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 60MA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-D-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC Series | DC integrated controller | 60LA motor support | Modbus RTU + I\/O | 24 VDC | Screw terminal | IP20 | with integrated motion controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817373986,"sku":"AUTONICS-AiC-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1438.png?v=1790653213"},{"product_id":"autonics-aic-cl-series-cc-link-2-phase-closed-loop-stepper-motor-system","title":"Autonics AiC-CL Series CC-Link 2-Phase Closed-Loop Stepper Motor System","description":"\u003cp class=\"ps-intro\"\u003eAiC variant with CC-Link communication.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eIntegrated motion controller with CC-Link slave interface for Mitsubishi PLC integration\u003c\/li\u003e\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-42SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 42SA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-42MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 42MA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-42LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 42LA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 56SA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 56MA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 56LA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 60SA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 60MA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-CL-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-CL Series | DC CC-Link | 60LA motor support | CC-Link communication | 24 VDC | Screw terminal | IP20 | CC-Link integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817406754,"sku":"AUTONICS-AiC-CL-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1442.png?v=1790653214"},{"product_id":"autonics-aic-ec-series-ethercat-2-phase-closed-loop-stepper-motor-system","title":"Autonics AiC-EC Series EtherCAT 2-Phase Closed-Loop Stepper Motor System","description":"\u003cp class=\"ps-intro\"\u003eAiC variant with EtherCAT communication.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eIntegrated motion controller with EtherCAT slave for high-speed deterministic motion control networks\u003c\/li\u003e\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-42SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 42SA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-42MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 42MA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-42LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 42LA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 56SA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 56MA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 56LA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 60SA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 60MA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-EC-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-EC Series | DC EtherCAT | 60LA motor support | EtherCAT slave | 24 VDC | RJ45 + Screw terminal | IP20 | EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817570594,"sku":"AUTONICS-AiC-EC-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1439.png?v=1790653215"},{"product_id":"autonics-aic-mt-series-modbus-tcp-2-phase-closed-loop-stepper-motor-system","title":"Autonics AiC-MT Series Modbus TCP 2-Phase Closed-Loop Stepper Motor System","description":"\u003cp class=\"ps-intro\"\u003eAiC variant with Modbus TCP\/IP communication.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eIntegrated motion controller with Modbus TCP slave for Ethernet-based control systems\u003c\/li\u003e\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-MT-42SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-MT Series | DC Modbus TCP | 42SA motor support | Modbus TCP\/IP | 24 VDC | RJ45 + Screw terminal | IP20 | Modbus TCP integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-MT-42MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-MT Series | DC Modbus TCP | 42MA motor support | Modbus TCP\/IP | 24 VDC | RJ45 + Screw terminal | IP20 | Modbus TCP integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-MT-42LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-MT Series | DC Modbus TCP | 42LA motor support | Modbus TCP\/IP | 24 VDC | RJ45 + Screw terminal | IP20 | Modbus TCP integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-MT-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-MT Series | DC Modbus TCP | 56SA motor support | Modbus TCP\/IP | 24 VDC | RJ45 + Screw terminal | IP20 | Modbus TCP integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-MT-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-MT Series | DC Modbus TCP | 56MA motor support | Modbus TCP\/IP | 24 VDC | RJ45 + Screw terminal | IP20 | Modbus TCP integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiC-MT-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiC-MT Series | DC Modbus TCP | 56LA motor support | Modbus TCP\/IP | 24 VDC | RJ45 + Screw terminal | IP20 | Modbus TCP integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817603362,"sku":"AUTONICS-AiC-MT-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1437.png?v=1790653216"},{"product_id":"autonics-aica-series-ac-power-2-phase-closed-loop-stepper-motor-system-with-integrated-controllers","title":"Autonics AiCA Series AC Power 2-Phase Closed-Loop Stepper Motor System with Integrated Controllers","description":"\u003cp class=\"ps-intro\"\u003eAC powered AiC variant with integrated motion controller.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFor high-torque applications using AC mains\u003c\/li\u003e\n\u003cli\u003eModbus RTU communication and digital I\/O\u003c\/li\u003e\n\u003cli\u003eSupports □ 56\/60\/85 mm motors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 56 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 56 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 56 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 60 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 60 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 60 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-85SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 85 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-85MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 85 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-D-85LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA Series | AC integrated controller | □ 85 mm motor support | Modbus RTU + I\/O | 100-240 VAC | Screw terminal | IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817701666,"sku":"AUTONICS-AiCA-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1436.png?v=1790653216"},{"product_id":"autonics-aica-ec-series-ac-power-ethercat-2-phase-closed-loop-stepper-motor-system","title":"Autonics AiCA-EC Series AC Power EtherCAT 2-Phase Closed-Loop Stepper Motor System","description":"\u003cp class=\"ps-intro\"\u003eAC powered AiC variant with EtherCAT communication.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eHigh-power closed-loop stepper system with EtherCAT slave interface\u003c\/li\u003e\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-56SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 56 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-56MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 56 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-56LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 56 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-60SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 60 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-60MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 60 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-60LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 60 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-85SA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 85 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-85MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 85 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAiCA-EC-85LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-loop stepper driver | AiCA-EC Series | AC EtherCAT | □ 85 mm motor | EtherCAT slave | 100-240 VAC | RJ45 + Screw terminal | IP20 | AC EtherCAT integrated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395817767202,"sku":"AUTONICS-AiCA-EC-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1432.png?v=1790653217"},{"product_id":"autonics-md2u-id20-series-intelligent-type-2-phase-stepper-motor-drivers","title":"Autonics MD2U-ID20 Series Intelligent Type 2-Phase Stepper Motor Drivers","description":"\u003cp class=\"ps-intro\"\u003eIntelligent type 2-phase stepper motor drivers with unipolar constant current drive.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSTOP current setting provides holding torque (brake function)\u003c\/li\u003e\n\u003cli\u003eIsolated photocoupler input minimizes electrical noise influence. 24-35 VDC power supply\u003c\/li\u003e\n\u003cli\u003eRUN current 0.5-2 A\/phase\u003c\/li\u003e\n\u003cli\u003eMax RUN speed 1500 rpm. 1.8°\/step basic step angle\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMD2U-ID20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD2U-ID20 Series | Intelligent 2-phase unipolar | 0.5-2 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | unipolar with STOP current\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395818324258,"sku":"AUTONICS-MD2U-ID20-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1435.png?v=1790653224"},{"product_id":"autonics-md2u-md20-series-micro-step-2-phase-stepper-motor-drivers","title":"Autonics MD2U-MD20 Series Micro Step 2-Phase Stepper Motor Drivers","description":"\u003cp class=\"ps-intro\"\u003eMicro-step 2-phase stepper motor drivers with bipolar constant current drive.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMultiple resolution settings (1\/2 to 1\/256 micro-step)\u003c\/li\u003e\n\u003cli\u003eSmooth motion and reduced motor vibration. 24-35 VDC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMD2U-MD20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD2U-MD20 Series | Micro-step 2-phase bipolar | 0.5-2 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | bipolar microstep up to 1\/256\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395818455330,"sku":"AUTONICS-MD2U-MD20-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1425.png?v=1790653224"},{"product_id":"autonics-md5-hd14-series-micro-step-5-phase-stepper-motor-drivers","title":"Autonics MD5-HD14 Series Micro Step 5-Phase Stepper Motor Drivers","description":"\u003cp class=\"ps-intro\"\u003eMicro-step 5-phase stepper motor drivers with bipolar constant current drive.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMultiple sub-models for different motor sizes and applications\u003c\/li\u003e\n\u003cli\u003ePower supply 24-35 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-HD14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase bipolar | 0.35-1.4 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | basic 5-phase microstep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-HD14-2X\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase 2-axis | 0.35-1.4 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | 2-axis 5-phase microstep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-HD14-3X\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase 3-axis | 0.35-1.4 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | 3-axis 5-phase microstep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-HF14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase high frequency | 0.35-1.4 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | high-frequency 5-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-HF14-AO\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase HF + alarm output | 0.35-1.4 A\/phase | photocoupler input + alarm | 24-35 VDC | Screw terminal | IP20 | with alarm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-HF28\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase HF higher current | 0.7-2.8 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | higher current 5-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD5-ND14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStepper driver | MD5-HD14 Series | Micro-step 5-phase basic | 0.35-1.4 A\/phase | photocoupler input | 24-35 VDC | Screw terminal | IP20 | basic 5-phase driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67395819176226,"sku":"AUTONICS-MD5-HD14-SERIES","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1419.png?v=1790653228"},{"product_id":"mitsubishi-electric-freqrol-fr-d710w-single-phase-100v-compact-inverter-0-1-0-75kw","title":"Mitsubishi Electric FREQROL FR-D710W Single-Phase 100V Compact Inverter (0.1-0.75kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-D710W general-purpose inverter (VFD), Single-Phase 100V input, 0.1-0.75kW (3-phase 200-230V output).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eSpring-clamp control terminals, 150% 60s \/ 200% 0.5s overload, IP20\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Power\u003c\/th\u003e\n\u003ctd\u003eSingle-phase 100-115V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Monitor\u003c\/th\u003e\n\u003ctd\u003eFM terminal (pulse train output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eSelf-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D710W-0.1K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D710W single-phase 100v inverter, 0.1kW, FM terminal | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A | Input Power: Single-phase 100-115V 50\/60Hz | Output Voltage: 3-phase 200-230V | Regen Braking Torque: 150% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D710W-0.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D710W single-phase 100v inverter, 0.2kW, FM terminal | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.4 A | Input Power: Single-phase 100-115V 50\/60Hz | Output Voltage: 3-phase 200-230V | Regen Braking Torque: 150% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D710W-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D710W single-phase 100v inverter, 0.4kW, FM terminal | Applied Motor: 0.4 kW | Rated Capacity: 1.0 kVA | Rated Current: 2.5 A | Input Power: Single-phase 100-115V 50\/60Hz | Output Voltage: 3-phase 200-230V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D710W-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D710W single-phase 100v inverter, 0.75kW, FM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 4.2 A | Input Power: Single-phase 100-115V 50\/60Hz | Output Voltage: 3-phase 200-230V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604100898,"sku":"MEL-FRD700-D710W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-11.png?v=1790662216"},{"product_id":"mitsubishi-electric-freqrol-fr-d720s-single-phase-200v-compact-inverter-0-1-2-2kw","title":"Mitsubishi Electric FREQROL FR-D720S Single-Phase 200V Compact Inverter (0.1-2.2kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-D720S general-purpose inverter (VFD), Single-Phase 200V input, 0.1-2.2kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eSpring-clamp control terminals, 150% 60s \/ 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Power\u003c\/th\u003e\n\u003ctd\u003eSingle-phase 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.1K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.1kW, FM terminal | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.1K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.1kW, AM terminal | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.2kW, FM terminal | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.4 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.2K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.2kW, AM terminal | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.4 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.4kW, FM terminal | Applied Motor: 0.4 kW | Rated Capacity: 1.0 kVA | Rated Current: 2.5 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.4K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.4kW, AM terminal | Applied Motor: 0.4 kW | Rated Capacity: 1.0 kVA | Rated Current: 2.5 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.75kW, FM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 4.2 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-0.75K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 0.75kW, AM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 4.2 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 1.5kW, FM terminal | Applied Motor: 1.5 kW | Rated Capacity: 2.8 kVA | Rated Current: 7.0 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 50% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-1.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 1.5kW, AM terminal | Applied Motor: 1.5 kW | Rated Capacity: 2.8 kVA | Rated Current: 7.0 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 50% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 2.2kW, FM terminal | Applied Motor: 2.2 kW | Rated Capacity: 4.0 kVA | Rated Current: 10.0 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720S-2.2K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720S single-phase 200v inverter, 2.2kW, AM terminal | Applied Motor: 2.2 kW | Rated Capacity: 4.0 kVA | Rated Current: 10.0 A | Input Power: Single-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604133666,"sku":"MEL-FRD700-D720S","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-11_490cd973-5d32-496f-95ed-1d374b920bf1.png?v=1790662217"},{"product_id":"mitsubishi-electric-freqrol-fr-d720-three-phase-200v-compact-inverter-0-1-15kw","title":"Mitsubishi Electric FREQROL FR-D720 Three-Phase 200V Compact Inverter (0.1-15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-D720 general-purpose inverter (VFD), Three-Phase 200V input, 0.1-15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eSpring-clamp control terminals, 150% 60s \/ 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Power\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.1K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.1kW, FM terminal | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.1K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.1kW, AM terminal | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.2kW, FM terminal | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.4 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.2K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.2kW, AM terminal | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.4 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 150% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.4kW, FM terminal | Applied Motor: 0.4 kW | Rated Capacity: 1.0 kVA | Rated Current: 2.5 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.4K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.4kW, AM terminal | Applied Motor: 0.4 kW | Rated Capacity: 1.0 kVA | Rated Current: 2.5 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.75kW, FM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 4.2 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-0.75K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 0.75kW, AM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 4.2 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 100% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 1.5kW, FM terminal | Applied Motor: 1.5 kW | Rated Capacity: 2.8 kVA | Rated Current: 7.0 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 50% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-1.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 1.5kW, AM terminal | Applied Motor: 1.5 kW | Rated Capacity: 2.8 kVA | Rated Current: 7.0 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 50% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 2.2kW, FM terminal | Applied Motor: 2.2 kW | Rated Capacity: 4.0 kVA | Rated Current: 10.0 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-2.2K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 2.2kW, AM terminal | Applied Motor: 2.2 kW | Rated Capacity: 4.0 kVA | Rated Current: 10.0 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 3.7kW, FM terminal | Applied Motor: 3.7 kW | Rated Capacity: 6.6 kVA | Rated Current: 16.5 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-3.7K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 3.7kW, AM terminal | Applied Motor: 3.7 kW | Rated Capacity: 6.6 kVA | Rated Current: 16.5 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 5.5kW, FM terminal | Applied Motor: 5.5 kW | Rated Capacity: 9.5 kVA | Rated Current: 23.8 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-5.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 5.5kW, AM terminal | Applied Motor: 5.5 kW | Rated Capacity: 9.5 kVA | Rated Current: 23.8 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 7.5kW, FM terminal | Applied Motor: 7.5 kW | Rated Capacity: 12.7 kVA | Rated Current: 31.8 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-7.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 7.5kW, AM terminal | Applied Motor: 7.5 kW | Rated Capacity: 12.7 kVA | Rated Current: 31.8 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 11kW, FM terminal | Applied Motor: 11 kW | Rated Capacity: 17.9 kVA | Rated Current: 45 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-11K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 11kW, AM terminal | Applied Motor: 11 kW | Rated Capacity: 17.1 kVA | Rated Current: 45 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 15kW, FM terminal | Applied Motor: 15 kW | Rated Capacity: 23.1 kVA | Rated Current: 58 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D720-15K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D720 three-phase 200v inverter, 15kW, AM terminal | Applied Motor: 15 kW | Rated Capacity: 22.1 kVA | Rated Current: 58 A | Input Power: 3-phase 200-240V 50\/60Hz | Output Voltage: 3-phase 200-240V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604199202,"sku":"MEL-FRD700-D720","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-11_ddcfa175-3fef-46d9-988b-203d2841693c.png?v=1790662218"},{"product_id":"mitsubishi-electric-freqrol-fr-d740-three-phase-400v-compact-inverter-0-4-15kw","title":"Mitsubishi Electric FREQROL FR-D740 Three-Phase 400V Compact Inverter (0.4-15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-D740 general-purpose inverter (VFD), Three-Phase 400V input, 0.4-15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eSpring-clamp control terminals, 150% 60s \/ 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Power\u003c\/th\u003e\n\u003ctd\u003e3-phase 380-480V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-phase 380-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 0.4kW, FM terminal | Applied Motor: 0.4 kW | Rated Capacity: 0.9 kVA | Rated Current: 1.2 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-0.4K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 0.4kW, AM terminal | Applied Motor: 0.4 kW | Rated Capacity: 0.9 kVA | Rated Current: 1.2 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 100% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 0.75kW, FM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 2.2 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 100% | Output Monitor: FM terminal (pulse train output) | Cooling: Self-cooling | Weight: 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-0.75K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 0.75kW, AM terminal | Applied Motor: 0.75 kW | Rated Capacity: 1.7 kVA | Rated Current: 2.2 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 100% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Self-cooling | Weight: 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 1.5kW, FM terminal | Applied Motor: 1.5 kW | Rated Capacity: 2.7 kVA | Rated Current: 3.6 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 50% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-1.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 1.5kW, AM terminal | Applied Motor: 1.5 kW | Rated Capacity: 2.7 kVA | Rated Current: 3.6 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 50% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 2.2kW, FM terminal | Applied Motor: 2.2 kW | Rated Capacity: 3.8 kVA | Rated Current: 5.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-2.2K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 2.2kW, AM terminal | Applied Motor: 2.2 kW | Rated Capacity: 3.8 kVA | Rated Current: 5.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 3.7kW, FM terminal | Applied Motor: 3.7 kW | Rated Capacity: 6.1 kVA | Rated Current: 8.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-3.7K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 3.7kW, AM terminal | Applied Motor: 3.7 kW | Rated Capacity: 6.1 kVA | Rated Current: 8.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 5.5kW, FM terminal | Applied Motor: 5.5 kW | Rated Capacity: 9.1 kVA | Rated Current: 12.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-5.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 5.5kW, AM terminal | Applied Motor: 5.5 kW | Rated Capacity: 9.1 kVA | Rated Current: 12.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 7.5kW, FM terminal | Applied Motor: 7.5 kW | Rated Capacity: 12.2 kVA | Rated Current: 16.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-7.5K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 7.5kW, AM terminal | Applied Motor: 7.5 kW | Rated Capacity: 12.2 kVA | Rated Current: 16.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 11kW, FM terminal | Applied Motor: 11 kW | Rated Capacity: 17.5 kVA | Rated Current: 23.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 6.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-11K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 11kW, AM terminal | Applied Motor: 11 kW | Rated Capacity: 17.5 kVA | Rated Current: 23.0 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 6.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 15kW, FM terminal | Applied Motor: 15 kW | Rated Capacity: 22.5 kVA | Rated Current: 29.5 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: FM terminal (pulse train output) | Cooling: Forced-air cooling | Weight: 6.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-D740-15K-EA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-D740 three-phase 400v inverter, 15kW, AM terminal | Applied Motor: 15 kW | Rated Capacity: 22.5 kVA | Rated Current: 29.5 A | Input Power: 3-phase 380-480V 50\/60Hz | Output Voltage: 3-phase 380-480V | Regen Braking Torque: 20% | Output Monitor: AM terminal (0-10V analog output) | Cooling: Forced-air cooling | Weight: 6.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604264738,"sku":"MEL-FRD700-D740","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-11_ad3bb302-31f0-42f6-8e2a-01f0d32b81bd.png?v=1790662219"},{"product_id":"mitsubishi-electric-freqrol-fr-a820-three-phase-200v-high-performance-inverter-0-4-90kw-nd","title":"Mitsubishi Electric FREQROL FR-A820 Three-Phase 200V High-Performance Inverter (0.4-90kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A820 high-performance general-purpose inverter (VFD), Three-Phase 200V, ND-rated 0.4-90kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector control, four selectable rating modes (SLD\/LD\/ND\/HD), FM\/CA output terminal; 150% 60s \/ 200% 3s ND overload\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 0.4kW (00046), sensorless vector | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 3 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00046 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 0.75kW (00077), sensorless vector | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00077 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 1.5kW (00105), sensorless vector | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 8 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00105 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 2.2kW (00167), sensorless vector | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 11 A | Rated Capacity (ND): 4.2 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00167 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 3.7kW (00250), sensorless vector | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 17.5 A | Rated Capacity (ND): 6.7 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 5.5kW (00340), sensorless vector | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 24 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00340 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 7.5kW (00490), sensorless vector | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 33 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00490 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 11kW (00630), sensorless vector | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 46 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00630 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 15kW (00770), sensorless vector | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 61 A | Rated Capacity (ND): 23 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-18.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 18.5kW (00930), sensorless vector | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 76 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-22K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 22kW (01250), sensorless vector | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 90 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01250 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-30K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 30kW (01540), sensorless vector | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 115 A | Rated Capacity (ND): 44 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01540 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-37K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 37kW (01870), sensorless vector | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 145 A | Rated Capacity (ND): 55 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01870 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-45K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 45kW (02330), sensorless vector | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 175 A | Rated Capacity (ND): 67 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02330 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-55K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 55kW (03160), sensorless vector | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75 kW | Rated Output Current (ND): 215 A | Rated Capacity (ND): 82 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03160 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 75kW (03800), sensorless vector | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 90\/110 kW | Rated Output Current (ND): 288 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03800 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-90K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820 three-phase 200v high-performance inverter, ND 90kW (04750), sensorless vector | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 346 A | Rated Capacity (ND): 132 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04750 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604330274,"sku":"MEL-FRA800-A820","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12.png?v=1790662221"},{"product_id":"mitsubishi-electric-freqrol-fr-a840-three-phase-400v-high-performance-inverter-0-4-280kw-nd","title":"Mitsubishi Electric FREQROL FR-A840 Three-Phase 400V High-Performance Inverter (0.4-280kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A840 high-performance general-purpose inverter (VFD), Three-Phase 400V, ND-rated 0.4-280kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector control, four selectable rating modes (SLD\/LD\/ND\/HD), FM\/CA output terminal; 150% 60s \/ 200% 3s ND overload\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 0.4kW (00023), sensorless vector | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00023 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 0.75kW (00038), sensorless vector | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00038 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 1.5kW (00052), sensorless vector | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00052 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 2.2kW (00083), sensorless vector | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00083 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 3.7kW (00126), sensorless vector | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00126 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 5.5kW (00170), sensorless vector | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00170 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 7.5kW (00250), sensorless vector | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 11kW (00310), sensorless vector | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00310 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 15kW (00380), sensorless vector | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00380 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-18.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 18.5kW (00470), sensorless vector | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00470 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-22K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 22kW (00620), sensorless vector | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00620 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-30K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 30kW (00770), sensorless vector | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-37K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 37kW (00930), sensorless vector | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-45K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 45kW (01160), sensorless vector | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01160 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-55K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 55kW (01800), sensorless vector | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75\/90 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01800 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 75kW (02160), sensorless vector | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 110 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02160 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-90K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 90kW (02600), sensorless vector | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02600 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-110K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 110kW (03250), sensorless vector | Applied Motor (ND): 110 kW | Max Applied Motor (SLD): 160 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03250 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-132K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 132kW (03610), sensorless vector | Applied Motor (ND): 132 kW | Max Applied Motor (SLD): 185 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03610 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-160K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 160kW (04320), sensorless vector | Applied Motor (ND): 160 kW | Max Applied Motor (SLD): 220 kW | Rated Output Current (ND): 325 A | Rated Capacity (ND): 248 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04320 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-185K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 185kW (04810), sensorless vector | Applied Motor (ND): 185 kW | Max Applied Motor (SLD): 250 kW | Rated Output Current (ND): 361 A | Rated Capacity (ND): 275 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04810 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-220K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 220kW (05470), sensorless vector | Applied Motor (ND): 220 kW | Max Applied Motor (SLD): 280 kW | Rated Output Current (ND): 432 A | Rated Capacity (ND): 329 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 05470 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-250K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 250kW (06100), sensorless vector | Applied Motor (ND): 250 kW | Max Applied Motor (SLD): 315 kW | Rated Output Current (ND): 481 A | Rated Capacity (ND): 367 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06100 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-280K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840 three-phase 400v high-performance inverter, ND 280kW (06830), sensorless vector | Applied Motor (ND): 280 kW | Max Applied Motor (SLD): 355 kW | Rated Output Current (ND): 547 A | Rated Capacity (ND): 417 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06830 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604363042,"sku":"MEL-FRA800-A840","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_e7e7e925-30c8-477a-8b31-e760b5236d98.png?v=1790662222"},{"product_id":"mitsubishi-electric-freqrol-fr-a820-e-three-phase-200v-high-performance-inverter-with-built-in-ethernet-0-4-90kw-nd","title":"Mitsubishi Electric FREQROL FR-A820-E Three-Phase 200V High-Performance Inverter with Built-in Ethernet (0.4-90kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A820-E high-performance inverter (VFD), Three-Phase 200V, ND 0.4-90kW, with built-in ethernet.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A820\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in Ethernet (EtherNet\/IP, Modbus\/TCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.4K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 0.4kW (00046), built-in ethernet | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 3 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00046 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.75K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 0.75kW (00077), built-in ethernet | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00077 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-1.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 1.5kW (00105), built-in ethernet | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 8 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00105 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-2.2K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 2.2kW (00167), built-in ethernet | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 11 A | Rated Capacity (ND): 4.2 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00167 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-3.7K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 3.7kW (00250), built-in ethernet | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 17.5 A | Rated Capacity (ND): 6.7 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-5.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 5.5kW (00340), built-in ethernet | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 24 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00340 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-7.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 7.5kW (00490), built-in ethernet | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 33 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00490 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-11K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 11kW (00630), built-in ethernet | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 46 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00630 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-15K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 15kW (00770), built-in ethernet | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 61 A | Rated Capacity (ND): 23 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-18.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 18.5kW (00930), built-in ethernet | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 76 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-22K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 22kW (01250), built-in ethernet | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 90 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01250 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-30K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 30kW (01540), built-in ethernet | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 115 A | Rated Capacity (ND): 44 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01540 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-37K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 37kW (01870), built-in ethernet | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 145 A | Rated Capacity (ND): 55 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01870 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-45K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 45kW (02330), built-in ethernet | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 175 A | Rated Capacity (ND): 67 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02330 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-55K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 55kW (03160), built-in ethernet | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75 kW | Rated Output Current (ND): 215 A | Rated Capacity (ND): 82 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03160 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-75K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 75kW (03800), built-in ethernet | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 90\/110 kW | Rated Output Current (ND): 288 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03800 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-90K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-E three-phase 200v inverter, ND 90kW (04750), built-in ethernet | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 346 A | Rated Capacity (ND): 132 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04750 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604395810,"sku":"MEL-FRA800-A820-E","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_1e061ac7-32ea-4606-871c-12f3c4e5796e.png?v=1790662223"},{"product_id":"mitsubishi-electric-freqrol-fr-a820-gf-three-phase-200v-high-performance-inverter-with-built-in-cc-link-ie-field-network-0-4-90kw-nd","title":"Mitsubishi Electric FREQROL FR-A820-GF Three-Phase 200V High-Performance Inverter with Built-in CC-Link IE Field Network (0.4-90kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A820-GF high-performance inverter (VFD), Three-Phase 200V, ND 0.4-90kW, with built-in cc-link ie field network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A820\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE Field Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.4K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 0.4kW (00046), built-in cc-link ie field network | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 3 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00046 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.75K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 0.75kW (00077), built-in cc-link ie field network | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00077 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-1.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 1.5kW (00105), built-in cc-link ie field network | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 8 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00105 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-2.2K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 2.2kW (00167), built-in cc-link ie field network | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 11 A | Rated Capacity (ND): 4.2 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00167 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-3.7K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 3.7kW (00250), built-in cc-link ie field network | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 17.5 A | Rated Capacity (ND): 6.7 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-5.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 5.5kW (00340), built-in cc-link ie field network | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 24 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00340 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-7.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 7.5kW (00490), built-in cc-link ie field network | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 33 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00490 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-11K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 11kW (00630), built-in cc-link ie field network | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 46 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00630 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-15K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 15kW (00770), built-in cc-link ie field network | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 61 A | Rated Capacity (ND): 23 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-18.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 18.5kW (00930), built-in cc-link ie field network | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 76 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-22K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 22kW (01250), built-in cc-link ie field network | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 90 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01250 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-30K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 30kW (01540), built-in cc-link ie field network | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 115 A | Rated Capacity (ND): 44 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01540 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-37K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 37kW (01870), built-in cc-link ie field network | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 145 A | Rated Capacity (ND): 55 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01870 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-45K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 45kW (02330), built-in cc-link ie field network | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 175 A | Rated Capacity (ND): 67 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02330 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-55K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 55kW (03160), built-in cc-link ie field network | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75 kW | Rated Output Current (ND): 215 A | Rated Capacity (ND): 82 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03160 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-75K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 75kW (03800), built-in cc-link ie field network | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 90\/110 kW | Rated Output Current (ND): 288 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03800 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-90K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GF three-phase 200v inverter, ND 90kW (04750), built-in cc-link ie field network | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 346 A | Rated Capacity (ND): 132 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04750 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604428578,"sku":"MEL-FRA800-A820-GF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_137fd9fd-a64b-4275-9fc9-05bdc0620478.png?v=1790662225"},{"product_id":"mitsubishi-electric-freqrol-fr-a820-gn-three-phase-200v-high-performance-inverter-with-built-in-cc-link-ie-tsn-0-4-90kw-nd","title":"Mitsubishi Electric FREQROL FR-A820-GN Three-Phase 200V High-Performance Inverter with Built-in CC-Link IE TSN (0.4-90kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A820-GN high-performance inverter (VFD), Three-Phase 200V, ND 0.4-90kW, with built-in cc-link ie tsn.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A820\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE TSN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.4K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 0.4kW (00046), built-in cc-link ie tsn | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 3 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00046 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-0.75K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 0.75kW (00077), built-in cc-link ie tsn | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00077 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-1.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 1.5kW (00105), built-in cc-link ie tsn | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 8 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00105 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-2.2K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 2.2kW (00167), built-in cc-link ie tsn | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 11 A | Rated Capacity (ND): 4.2 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00167 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-3.7K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 3.7kW (00250), built-in cc-link ie tsn | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 17.5 A | Rated Capacity (ND): 6.7 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-5.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 5.5kW (00340), built-in cc-link ie tsn | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 24 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00340 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-7.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 7.5kW (00490), built-in cc-link ie tsn | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 33 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00490 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-11K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 11kW (00630), built-in cc-link ie tsn | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 46 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00630 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-15K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 15kW (00770), built-in cc-link ie tsn | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 61 A | Rated Capacity (ND): 23 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-18.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 18.5kW (00930), built-in cc-link ie tsn | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 76 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-22K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 22kW (01250), built-in cc-link ie tsn | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 90 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01250 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-30K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 30kW (01540), built-in cc-link ie tsn | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 115 A | Rated Capacity (ND): 44 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01540 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-37K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 37kW (01870), built-in cc-link ie tsn | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 145 A | Rated Capacity (ND): 55 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01870 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-45K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 45kW (02330), built-in cc-link ie tsn | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 175 A | Rated Capacity (ND): 67 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02330 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-55K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 55kW (03160), built-in cc-link ie tsn | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75 kW | Rated Output Current (ND): 215 A | Rated Capacity (ND): 82 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03160 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-75K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 75kW (03800), built-in cc-link ie tsn | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 90\/110 kW | Rated Output Current (ND): 288 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03800 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A820-90K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A820-GN three-phase 200v inverter, ND 90kW (04750), built-in cc-link ie tsn | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 346 A | Rated Capacity (ND): 132 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04750 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604461346,"sku":"MEL-FRA800-A820-GN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_ee7c8a8e-162f-434a-8377-836c7d005588.png?v=1790662226"},{"product_id":"mitsubishi-electric-freqrol-fr-a840-e-three-phase-400v-high-performance-inverter-with-built-in-ethernet-0-4-280kw-nd","title":"Mitsubishi Electric FREQROL FR-A840-E Three-Phase 400V High-Performance Inverter with Built-in Ethernet (0.4-280kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A840-E high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in ethernet.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A840\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in Ethernet (EtherNet\/IP, Modbus\/TCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.4K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 0.4kW (00023), built-in ethernet | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00023 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.75K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 0.75kW (00038), built-in ethernet | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00038 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-1.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 1.5kW (00052), built-in ethernet | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00052 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-2.2K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 2.2kW (00083), built-in ethernet | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00083 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-3.7K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 3.7kW (00126), built-in ethernet | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00126 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-5.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 5.5kW (00170), built-in ethernet | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00170 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-7.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 7.5kW (00250), built-in ethernet | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-11K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 11kW (00310), built-in ethernet | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00310 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-15K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 15kW (00380), built-in ethernet | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00380 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-18.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 18.5kW (00470), built-in ethernet | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00470 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-22K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 22kW (00620), built-in ethernet | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00620 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-30K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 30kW (00770), built-in ethernet | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-37K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 37kW (00930), built-in ethernet | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-45K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 45kW (01160), built-in ethernet | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01160 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-55K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 55kW (01800), built-in ethernet | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75\/90 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01800 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-75K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 75kW (02160), built-in ethernet | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 110 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02160 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-90K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 90kW (02600), built-in ethernet | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02600 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-110K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 110kW (03250), built-in ethernet | Applied Motor (ND): 110 kW | Max Applied Motor (SLD): 160 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03250 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-132K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 132kW (03610), built-in ethernet | Applied Motor (ND): 132 kW | Max Applied Motor (SLD): 185 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03610 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-160K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 160kW (04320), built-in ethernet | Applied Motor (ND): 160 kW | Max Applied Motor (SLD): 220 kW | Rated Output Current (ND): 325 A | Rated Capacity (ND): 248 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04320 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-185K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 185kW (04810), built-in ethernet | Applied Motor (ND): 185 kW | Max Applied Motor (SLD): 250 kW | Rated Output Current (ND): 361 A | Rated Capacity (ND): 275 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04810 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-220K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 220kW (05470), built-in ethernet | Applied Motor (ND): 220 kW | Max Applied Motor (SLD): 280 kW | Rated Output Current (ND): 432 A | Rated Capacity (ND): 329 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 05470 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-250K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 250kW (06100), built-in ethernet | Applied Motor (ND): 250 kW | Max Applied Motor (SLD): 315 kW | Rated Output Current (ND): 481 A | Rated Capacity (ND): 367 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06100 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-280K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-E three-phase 400v inverter, ND 280kW (06830), built-in ethernet | Applied Motor (ND): 280 kW | Max Applied Motor (SLD): 355 kW | Rated Output Current (ND): 547 A | Rated Capacity (ND): 417 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06830 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604494114,"sku":"MEL-FRA800-A840-E","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_31a093c5-d940-4c94-b5ca-5622f4132b56.png?v=1790662227"},{"product_id":"mitsubishi-electric-freqrol-fr-a840-gf-three-phase-400v-high-performance-inverter-with-built-in-cc-link-ie-field-network-0-4-280kw-nd","title":"Mitsubishi Electric FREQROL FR-A840-GF Three-Phase 400V High-Performance Inverter with Built-in CC-Link IE Field Network (0.4-280kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A840-GF high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie field network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A840\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE Field Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.4K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 0.4kW (00023), built-in cc-link ie field network | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00023 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.75K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 0.75kW (00038), built-in cc-link ie field network | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00038 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-1.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 1.5kW (00052), built-in cc-link ie field network | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00052 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-2.2K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 2.2kW (00083), built-in cc-link ie field network | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00083 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-3.7K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 3.7kW (00126), built-in cc-link ie field network | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00126 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-5.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 5.5kW (00170), built-in cc-link ie field network | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00170 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-7.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 7.5kW (00250), built-in cc-link ie field network | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-11K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 11kW (00310), built-in cc-link ie field network | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00310 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-15K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 15kW (00380), built-in cc-link ie field network | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00380 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-18.5K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 18.5kW (00470), built-in cc-link ie field network | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00470 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-22K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 22kW (00620), built-in cc-link ie field network | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00620 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-30K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 30kW (00770), built-in cc-link ie field network | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-37K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 37kW (00930), built-in cc-link ie field network | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-45K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 45kW (01160), built-in cc-link ie field network | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01160 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-55K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 55kW (01800), built-in cc-link ie field network | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75\/90 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01800 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-75K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 75kW (02160), built-in cc-link ie field network | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 110 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02160 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-90K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 90kW (02600), built-in cc-link ie field network | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02600 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-110K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 110kW (03250), built-in cc-link ie field network | Applied Motor (ND): 110 kW | Max Applied Motor (SLD): 160 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03250 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-132K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 132kW (03610), built-in cc-link ie field network | Applied Motor (ND): 132 kW | Max Applied Motor (SLD): 185 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03610 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-160K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 160kW (04320), built-in cc-link ie field network | Applied Motor (ND): 160 kW | Max Applied Motor (SLD): 220 kW | Rated Output Current (ND): 325 A | Rated Capacity (ND): 248 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04320 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-185K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 185kW (04810), built-in cc-link ie field network | Applied Motor (ND): 185 kW | Max Applied Motor (SLD): 250 kW | Rated Output Current (ND): 361 A | Rated Capacity (ND): 275 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04810 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-220K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 220kW (05470), built-in cc-link ie field network | Applied Motor (ND): 220 kW | Max Applied Motor (SLD): 280 kW | Rated Output Current (ND): 432 A | Rated Capacity (ND): 329 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 05470 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-250K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 250kW (06100), built-in cc-link ie field network | Applied Motor (ND): 250 kW | Max Applied Motor (SLD): 315 kW | Rated Output Current (ND): 481 A | Rated Capacity (ND): 367 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06100 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-280K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GF three-phase 400v inverter, ND 280kW (06830), built-in cc-link ie field network | Applied Motor (ND): 280 kW | Max Applied Motor (SLD): 355 kW | Rated Output Current (ND): 547 A | Rated Capacity (ND): 417 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06830 | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604526882,"sku":"MEL-FRA800-A840-GF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_ee792cdd-310c-4c07-bb25-683ba3fce473.png?v=1790662229"},{"product_id":"mitsubishi-electric-freqrol-fr-a840-gn-three-phase-400v-high-performance-inverter-with-built-in-cc-link-ie-tsn-0-4-280kw-nd","title":"Mitsubishi Electric FREQROL FR-A840-GN Three-Phase 400V High-Performance Inverter with Built-in CC-Link IE TSN (0.4-280kW ND)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A840-GN high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie tsn.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, SLD\/LD\/ND\/HD selectable rating, FM\/CA output; same ratings as standard FR-A840\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE TSN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.4K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 0.4kW (00023), built-in cc-link ie tsn | Applied Motor (ND): 0.4 kW | Max Applied Motor (SLD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00023 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-0.75K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 0.75kW (00038), built-in cc-link ie tsn | Applied Motor (ND): 0.75 kW | Max Applied Motor (SLD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00038 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-1.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 1.5kW (00052), built-in cc-link ie tsn | Applied Motor (ND): 1.5 kW | Max Applied Motor (SLD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00052 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self-cooling | Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-2.2K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 2.2kW (00083), built-in cc-link ie tsn | Applied Motor (ND): 2.2 kW | Max Applied Motor (SLD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00083 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-3.7K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 3.7kW (00126), built-in cc-link ie tsn | Applied Motor (ND): 3.7 kW | Max Applied Motor (SLD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00126 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-5.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 5.5kW (00170), built-in cc-link ie tsn | Applied Motor (ND): 5.5 kW | Max Applied Motor (SLD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00170 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-7.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 7.5kW (00250), built-in cc-link ie tsn | Applied Motor (ND): 7.5 kW | Max Applied Motor (SLD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00250 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 6.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-11K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 11kW (00310), built-in cc-link ie tsn | Applied Motor (ND): 11 kW | Max Applied Motor (SLD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00310 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-15K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 15kW (00380), built-in cc-link ie tsn | Applied Motor (ND): 15 kW | Max Applied Motor (SLD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00380 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 8.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-18.5K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 18.5kW (00470), built-in cc-link ie tsn | Applied Motor (ND): 18.5 kW | Max Applied Motor (SLD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00470 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-22K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 22kW (00620), built-in cc-link ie tsn | Applied Motor (ND): 22 kW | Max Applied Motor (SLD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00620 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-30K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 30kW (00770), built-in cc-link ie tsn | Applied Motor (ND): 30 kW | Max Applied Motor (SLD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00770 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-37K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 37kW (00930), built-in cc-link ie tsn | Applied Motor (ND): 37 kW | Max Applied Motor (SLD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 00930 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-45K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 45kW (01160), built-in cc-link ie tsn | Applied Motor (ND): 45 kW | Max Applied Motor (SLD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01160 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-55K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 55kW (01800), built-in cc-link ie tsn | Applied Motor (ND): 55 kW | Max Applied Motor (SLD): 75\/90 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 01800 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-75K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 75kW (02160), built-in cc-link ie tsn | Applied Motor (ND): 75 kW | Max Applied Motor (SLD): 110 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02160 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-90K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 90kW (02600), built-in cc-link ie tsn | Applied Motor (ND): 90 kW | Max Applied Motor (SLD): 132 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 02600 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-110K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 110kW (03250), built-in cc-link ie tsn | Applied Motor (ND): 110 kW | Max Applied Motor (SLD): 160 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03250 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-132K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 132kW (03610), built-in cc-link ie tsn | Applied Motor (ND): 132 kW | Max Applied Motor (SLD): 185 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 03610 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-160K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 160kW (04320), built-in cc-link ie tsn | Applied Motor (ND): 160 kW | Max Applied Motor (SLD): 220 kW | Rated Output Current (ND): 325 A | Rated Capacity (ND): 248 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04320 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-185K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 185kW (04810), built-in cc-link ie tsn | Applied Motor (ND): 185 kW | Max Applied Motor (SLD): 250 kW | Rated Output Current (ND): 361 A | Rated Capacity (ND): 275 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 04810 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 117 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-220K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 220kW (05470), built-in cc-link ie tsn | Applied Motor (ND): 220 kW | Max Applied Motor (SLD): 280 kW | Rated Output Current (ND): 432 A | Rated Capacity (ND): 329 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 05470 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-250K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 250kW (06100), built-in cc-link ie tsn | Applied Motor (ND): 250 kW | Max Applied Motor (SLD): 315 kW | Rated Output Current (ND): 481 A | Rated Capacity (ND): 367 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06100 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A840-280K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-GN three-phase 400v inverter, ND 280kW (06830), built-in cc-link ie tsn | Applied Motor (ND): 280 kW | Max Applied Motor (SLD): 355 kW | Rated Output Current (ND): 547 A | Rated Capacity (ND): 417 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 06830 | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Weight: 166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604592418,"sku":"MEL-FRA800-A840-GN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_13435b25-d7f6-42cb-8448-9dfcbeaa0ee7.png?v=1790662230"},{"product_id":"mitsubishi-electric-freqrol-fr-a842-three-phase-400v-separate-converter-inverter-315-500kw-nd-requires-fr-cc2-converter","title":"Mitsubishi Electric FREQROL FR-A842 Three-Phase 400V Separate Converter Inverter (315-500kW ND, requires FR-CC2 converter)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A842 separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eDC bus input (requires FR-CC2 converter unit), SLD\/LD\/ND\/HD rating, IP00\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003eDC 430-780V (separate converter type, requires FR-CC2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced-air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP00 (open chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-315K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842 three-phase 400v separate-converter inverter, ND 315kW (07700) | Applied Motor (ND): 315 kW | Max Applied Motor (SLD): 400 kW | Rated Output Current (ND): 610 A | Rated Capacity (ND): 465 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 07700 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-355K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842 three-phase 400v separate-converter inverter, ND 355kW (08660) | Applied Motor (ND): 355 kW | Max Applied Motor (SLD): 450 kW | Rated Output Current (ND): 683 A | Rated Capacity (ND): 521 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 08660 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-400K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842 three-phase 400v separate-converter inverter, ND 400kW (09620) | Applied Motor (ND): 400 kW | Max Applied Motor (SLD): 500 kW | Rated Output Current (ND): 770 A | Rated Capacity (ND): 587 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 09620 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-450K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842 three-phase 400v separate-converter inverter, ND 450kW (10940) | Applied Motor (ND): 450 kW | Max Applied Motor (SLD): 560 kW | Rated Output Current (ND): 866 A | Rated Capacity (ND): 660 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 10940 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-500K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842 three-phase 400v separate-converter inverter, ND 500kW (12120) | Applied Motor (ND): 500 kW | Max Applied Motor (SLD): 630 kW | Rated Output Current (ND): 962 A | Rated Capacity (ND): 733 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 12120 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604625186,"sku":"MEL-FRA800-A842","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_829422b6-e30b-4acc-9b99-aebf65647f78.png?v=1790662231"},{"product_id":"mitsubishi-electric-freqrol-fr-a842-e-three-phase-400v-with-built-in-ethernet-315-500kw-nd-requires-fr-cc2-converter","title":"Mitsubishi Electric FREQROL FR-A842-E Three-Phase 400V with Built-in Ethernet (315-500kW ND, requires FR-CC2 converter)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A842-E separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in ethernet (ethernet\/ip, modbus\/tcp).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eDC bus input (requires FR-CC2 converter unit), SLD\/LD\/ND\/HD rating, IP00\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003eDC 430-780V (separate converter type, requires FR-CC2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in Ethernet (EtherNet\/IP, Modbus\/TCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced-air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP00 (open chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-315K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-E three-phase 400v separate-converter inverter, ND 315kW (07700) | Applied Motor (ND): 315 kW | Max Applied Motor (SLD): 400 kW | Rated Output Current (ND): 610 A | Rated Capacity (ND): 465 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 07700 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-355K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-E three-phase 400v separate-converter inverter, ND 355kW (08660) | Applied Motor (ND): 355 kW | Max Applied Motor (SLD): 450 kW | Rated Output Current (ND): 683 A | Rated Capacity (ND): 521 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 08660 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-400K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-E three-phase 400v separate-converter inverter, ND 400kW (09620) | Applied Motor (ND): 400 kW | Max Applied Motor (SLD): 500 kW | Rated Output Current (ND): 770 A | Rated Capacity (ND): 587 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 09620 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-450K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-E three-phase 400v separate-converter inverter, ND 450kW (10940) | Applied Motor (ND): 450 kW | Max Applied Motor (SLD): 560 kW | Rated Output Current (ND): 866 A | Rated Capacity (ND): 660 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 10940 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-500K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-E three-phase 400v separate-converter inverter, ND 500kW (12120) | Applied Motor (ND): 500 kW | Max Applied Motor (SLD): 630 kW | Rated Output Current (ND): 962 A | Rated Capacity (ND): 733 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 12120 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604657954,"sku":"MEL-FRA800-A842-E","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_e3097231-b7e6-4cf6-a11e-e777fcf4fed0.png?v=1790662233"},{"product_id":"mitsubishi-electric-freqrol-fr-a842-gf-three-phase-400v-with-built-in-cc-link-ie-field-315-500kw-nd-requires-fr-cc2-converter","title":"Mitsubishi Electric FREQROL FR-A842-GF Three-Phase 400V with Built-in CC-Link IE Field (315-500kW ND, requires FR-CC2 converter)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A842-GF separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in cc-link ie field network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eDC bus input (requires FR-CC2 converter unit), SLD\/LD\/ND\/HD rating, IP00\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003eDC 430-780V (separate converter type, requires FR-CC2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE Field Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced-air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP00 (open chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-315K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GF three-phase 400v separate-converter inverter, ND 315kW (07700) | Applied Motor (ND): 315 kW | Max Applied Motor (SLD): 400 kW | Rated Output Current (ND): 610 A | Rated Capacity (ND): 465 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 07700 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-355K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GF three-phase 400v separate-converter inverter, ND 355kW (08660) | Applied Motor (ND): 355 kW | Max Applied Motor (SLD): 450 kW | Rated Output Current (ND): 683 A | Rated Capacity (ND): 521 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 08660 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-400K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GF three-phase 400v separate-converter inverter, ND 400kW (09620) | Applied Motor (ND): 400 kW | Max Applied Motor (SLD): 500 kW | Rated Output Current (ND): 770 A | Rated Capacity (ND): 587 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 09620 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-450K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GF three-phase 400v separate-converter inverter, ND 450kW (10940) | Applied Motor (ND): 450 kW | Max Applied Motor (SLD): 560 kW | Rated Output Current (ND): 866 A | Rated Capacity (ND): 660 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 10940 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-500K-GF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GF three-phase 400v separate-converter inverter, ND 500kW (12120) | Applied Motor (ND): 500 kW | Max Applied Motor (SLD): 630 kW | Rated Output Current (ND): 962 A | Rated Capacity (ND): 733 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 12120 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE Field Network | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604690722,"sku":"MEL-FRA800-A842-GF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_19c3b785-9f69-49fa-b6b7-d7393847d5f9.png?v=1790662234"},{"product_id":"mitsubishi-electric-freqrol-fr-a842-gn-three-phase-400v-with-built-in-cc-link-ie-tsn-315-500kw-nd-requires-fr-cc2-converter","title":"Mitsubishi Electric FREQROL FR-A842-GN Three-Phase 400V with Built-in CC-Link IE TSN (315-500kW ND, requires FR-CC2 converter)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A842-GN separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in cc-link ie tsn.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eDC bus input (requires FR-CC2 converter unit), SLD\/LD\/ND\/HD rating, IP00\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eSLD\/LD\/ND\/HD selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003eDC 430-780V (separate converter type, requires FR-CC2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in CC-Link IE TSN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced-air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP00 (open chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-315K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GN three-phase 400v separate-converter inverter, ND 315kW (07700) | Applied Motor (ND): 315 kW | Max Applied Motor (SLD): 400 kW | Rated Output Current (ND): 610 A | Rated Capacity (ND): 465 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 07700 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-355K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GN three-phase 400v separate-converter inverter, ND 355kW (08660) | Applied Motor (ND): 355 kW | Max Applied Motor (SLD): 450 kW | Rated Output Current (ND): 683 A | Rated Capacity (ND): 521 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 08660 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 163 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-400K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GN three-phase 400v separate-converter inverter, ND 400kW (09620) | Applied Motor (ND): 400 kW | Max Applied Motor (SLD): 500 kW | Rated Output Current (ND): 770 A | Rated Capacity (ND): 587 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 09620 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-450K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GN three-phase 400v separate-converter inverter, ND 450kW (10940) | Applied Motor (ND): 450 kW | Max Applied Motor (SLD): 560 kW | Rated Output Current (ND): 866 A | Rated Capacity (ND): 660 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 10940 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-500K-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-GN three-phase 400v separate-converter inverter, ND 500kW (12120) | Applied Motor (ND): 500 kW | Max Applied Motor (SLD): 630 kW | Rated Output Current (ND): 962 A | Rated Capacity (ND): 733 kVA | Rating Modes: SLD\/LD\/ND\/HD selectable | Inverter Rating Code: 12120 | Input: DC 430-780V (separate converter type, requires FR-CC2) | Network Interface: Built-in CC-Link IE TSN | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight: 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604723490,"sku":"MEL-FRA800-A842-GN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_18976975-8d0b-4442-914b-2c67e02c69da.png?v=1790662235"},{"product_id":"mitsubishi-electric-freqrol-fr-a846-three-phase-400v-ip55-inverter-0-4-132kw-nd-ip55","title":"Mitsubishi Electric FREQROL FR-A846 Three-Phase 400V IP55 Inverter (0.4-132kW ND, IP55)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A846 IP55 dust\/water-proof high-performance inverter (VFD), Three-Phase 400V, ND 0.4-132kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, LD\/ND selectable rating, IP55 \/ UL Type 12, internal circulation fan\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eLD\/ND selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP55 (dust\/water-proof), UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eSelf\/Forced-air cooling + internal circulation fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 0.4kW (00023) | Applied Motor (ND): 0.4 kW | Max Applied Motor (LD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00023 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 0.75kW (00038) | Applied Motor (ND): 0.75 kW | Max Applied Motor (LD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00038 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 1.5kW (00052) | Applied Motor (ND): 1.5 kW | Max Applied Motor (LD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00052 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 2.2kW (00083) | Applied Motor (ND): 2.2 kW | Max Applied Motor (LD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00083 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 3.7kW (00126) | Applied Motor (ND): 3.7 kW | Max Applied Motor (LD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00126 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 5.5kW (00170) | Applied Motor (ND): 5.5 kW | Max Applied Motor (LD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00170 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 7.5kW (00250) | Applied Motor (ND): 7.5 kW | Max Applied Motor (LD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00250 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 11kW (00310) | Applied Motor (ND): 11 kW | Max Applied Motor (LD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00310 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 15kW (00380) | Applied Motor (ND): 15 kW | Max Applied Motor (LD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00380 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-18.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 18.5kW (00470) | Applied Motor (ND): 18.5 kW | Max Applied Motor (LD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00470 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-22K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 22kW (00620) | Applied Motor (ND): 22 kW | Max Applied Motor (LD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00620 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 59 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-30K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 30kW (00770) | Applied Motor (ND): 30 kW | Max Applied Motor (LD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00770 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-37K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 37kW (00930) | Applied Motor (ND): 37 kW | Max Applied Motor (LD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00930 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-45K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 45kW (01160) | Applied Motor (ND): 45 kW | Max Applied Motor (LD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 01160 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-55K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 55kW (01800) | Applied Motor (ND): 55 kW | Max Applied Motor (LD): 75 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 01800 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 147 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 75kW (02160) | Applied Motor (ND): 75 kW | Max Applied Motor (LD): 90 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 02160 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 150 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-90K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 90kW (02600) | Applied Motor (ND): 90 kW | Max Applied Motor (LD): 110 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 02600 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 153 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-110K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 110kW (03250) | Applied Motor (ND): 110 kW | Max Applied Motor (LD): 132 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 03250 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 189 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-132K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846 three-phase 400v IP55 inverter, ND 132kW (03610) | Applied Motor (ND): 132 kW | Max Applied Motor (LD): 160 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 03610 | Protection: IP55 (dust\/water-proof), UL Type 12 | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 193 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604756258,"sku":"MEL-FRA800-A846","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_4f000a2f-4846-45c3-8e9f-a482bf7e0d4e.png?v=1790662237"},{"product_id":"mitsubishi-electric-freqrol-fr-a846-e-three-phase-400v-ip55-inverter-with-built-in-ethernet-0-4-132kw-nd-ip55","title":"Mitsubishi Electric FREQROL FR-A846-E Three-Phase 400V IP55 Inverter with Built-in Ethernet (0.4-132kW ND, IP55)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A846-E IP55 dust\/water-proof high-performance inverter (VFD), Three-Phase 400V, ND 0.4-132kW built-in ethernet (ethernet\/ip, modbus\/tcp).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eReal\/PM sensorless vector, LD\/ND selectable rating, IP55 \/ UL Type 12, internal circulation fan\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eLD\/ND selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP55 (dust\/water-proof), UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd\u003eBuilt-in Ethernet (EtherNet\/IP, Modbus\/TCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eSelf\/Forced-air cooling + internal circulation fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-0.4K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 0.4kW (00023) | Applied Motor (ND): 0.4 kW | Max Applied Motor (LD): 0.75 kW | Rated Output Current (ND): 1.5 A | Rated Capacity (ND): 1.1 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00023 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-0.75K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 0.75kW (00038) | Applied Motor (ND): 0.75 kW | Max Applied Motor (LD): 1.5 kW | Rated Output Current (ND): 2.5 A | Rated Capacity (ND): 1.9 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00038 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-1.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 1.5kW (00052) | Applied Motor (ND): 1.5 kW | Max Applied Motor (LD): 2.2 kW | Rated Output Current (ND): 4 A | Rated Capacity (ND): 3 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00052 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-2.2K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 2.2kW (00083) | Applied Motor (ND): 2.2 kW | Max Applied Motor (LD): 3.7 kW | Rated Output Current (ND): 6 A | Rated Capacity (ND): 4.6 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00083 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-3.7K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 3.7kW (00126) | Applied Motor (ND): 3.7 kW | Max Applied Motor (LD): 5.5 kW | Rated Output Current (ND): 9 A | Rated Capacity (ND): 6.9 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00126 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-5.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 5.5kW (00170) | Applied Motor (ND): 5.5 kW | Max Applied Motor (LD): 7.5 kW | Rated Output Current (ND): 12 A | Rated Capacity (ND): 9.1 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00170 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-7.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 7.5kW (00250) | Applied Motor (ND): 7.5 kW | Max Applied Motor (LD): 11 kW | Rated Output Current (ND): 17 A | Rated Capacity (ND): 13 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00250 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-11K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 11kW (00310) | Applied Motor (ND): 11 kW | Max Applied Motor (LD): 15 kW | Rated Output Current (ND): 23 A | Rated Capacity (ND): 18 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00310 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-15K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 15kW (00380) | Applied Motor (ND): 15 kW | Max Applied Motor (LD): 18.5 kW | Rated Output Current (ND): 31 A | Rated Capacity (ND): 24 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00380 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-18.5K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 18.5kW (00470) | Applied Motor (ND): 18.5 kW | Max Applied Motor (LD): 22 kW | Rated Output Current (ND): 38 A | Rated Capacity (ND): 29 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00470 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-22K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 22kW (00620) | Applied Motor (ND): 22 kW | Max Applied Motor (LD): 30 kW | Rated Output Current (ND): 44 A | Rated Capacity (ND): 34 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00620 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 59 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-30K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 30kW (00770) | Applied Motor (ND): 30 kW | Max Applied Motor (LD): 37 kW | Rated Output Current (ND): 57 A | Rated Capacity (ND): 43 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00770 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-37K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 37kW (00930) | Applied Motor (ND): 37 kW | Max Applied Motor (LD): 45 kW | Rated Output Current (ND): 71 A | Rated Capacity (ND): 54 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 00930 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-45K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 45kW (01160) | Applied Motor (ND): 45 kW | Max Applied Motor (LD): 55 kW | Rated Output Current (ND): 86 A | Rated Capacity (ND): 66 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 01160 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-55K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 55kW (01800) | Applied Motor (ND): 55 kW | Max Applied Motor (LD): 75 kW | Rated Output Current (ND): 110 A | Rated Capacity (ND): 84 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 01800 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 147 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-75K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 75kW (02160) | Applied Motor (ND): 75 kW | Max Applied Motor (LD): 90 kW | Rated Output Current (ND): 144 A | Rated Capacity (ND): 110 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 02160 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 150 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-90K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 90kW (02600) | Applied Motor (ND): 90 kW | Max Applied Motor (LD): 110 kW | Rated Output Current (ND): 180 A | Rated Capacity (ND): 137 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 02600 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 153 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-110K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 110kW (03250) | Applied Motor (ND): 110 kW | Max Applied Motor (LD): 132 kW | Rated Output Current (ND): 216 A | Rated Capacity (ND): 165 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 03250 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 189 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A846-132K-E\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A846-E three-phase 400v IP55 inverter, ND 132kW (03610) | Applied Motor (ND): 132 kW | Max Applied Motor (LD): 160 kW | Rated Output Current (ND): 260 A | Rated Capacity (ND): 198 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 03610 | Protection: IP55 (dust\/water-proof), UL Type 12 | Network Interface: Built-in Ethernet (EtherNet\/IP, Modbus\/TCP) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Self\/Forced-air cooling + internal circulation fan | Weight: 193 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604789026,"sku":"MEL-FRA800-A846-E","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_ab35a469-4907-4245-9386-9943f559bc6e.png?v=1790662238"},{"product_id":"mitsubishi-electric-freqrol-fr-a842-p-three-phase-400v-parallel-operation-separate-converter-inverter-2-3-unit-parallel-up-to-1200kw-nd-requires-fr-cc2","title":"Mitsubishi Electric FREQROL FR-A842-P Three-Phase 400V Parallel-Operation Separate Converter Inverter (2\/3-unit parallel, up to 1200kW ND, requires FR-CC2)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A842-P parallel-operation high-performance inverter (VFD), three-phase 400V, for 2-unit or 3-unit parallel drive up to 1200kW ND.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eDC bus input (requires FR-CC2 converter), LD\/ND rating, IP00; base units 400\/450\/500K\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eParallel-operation inverter (separate converter type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRating Modes\u003c\/th\u003e\n\u003ctd\u003eLD\/ND selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003eDC 430-780V (requires FR-CC2 converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Terminal\u003c\/th\u003e\n\u003ctd\u003eFM (pulse) \/ CA (0-10V analog), Pr.54 selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eForced-air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP00 (open chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight (per unit)\u003c\/th\u003e\n\u003ctd\u003e243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-400K-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-400K-P parallel-operation 400V inverter (09620), 2\/3-unit parallel | Configuration: Parallel-operation inverter (separate converter type) | Base Unit: FR-A842-400K-P (243 kg\/unit) | 2-unit Parallel Motor (ND\/LD): 630\/710 kW | 2-unit Parallel Current (ND): 1232 A | 2-unit Parallel Capacity (ND): 939 kVA | 3-unit Parallel Motor (ND\/LD): 945\/1065 kW | 3-unit Parallel Current (ND): 1848 A | 3-unit Parallel Capacity (ND): 1409 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 09620 | Input: DC 430-780V (requires FR-CC2 converter) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight (per unit): 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-450K-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-450K-P parallel-operation 400V inverter (10940), 2\/3-unit parallel | Configuration: Parallel-operation inverter (separate converter type) | Base Unit: FR-A842-450K-P (243 kg\/unit) | 2-unit Parallel Motor (ND\/LD): 710\/800 kW | 2-unit Parallel Current (ND): 1386 A | 2-unit Parallel Capacity (ND): 1056 kVA | 3-unit Parallel Motor (ND\/LD): 1065\/1200 kW | 3-unit Parallel Current (ND): 2078 A | 3-unit Parallel Capacity (ND): 1584 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 10940 | Input: DC 430-780V (requires FR-CC2 converter) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight (per unit): 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A842-500K-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A842-500K-P parallel-operation 400V inverter (12120), 2\/3-unit parallel | Configuration: Parallel-operation inverter (separate converter type) | Base Unit: FR-A842-500K-P (243 kg\/unit) | 2-unit Parallel Motor (ND\/LD): 800\/900 kW | 2-unit Parallel Current (ND): 1539 A | 2-unit Parallel Capacity (ND): 1173 kVA | 3-unit Parallel Motor (ND\/LD): 1200\/1350 kW | 3-unit Parallel Current (ND): 2309 A | 3-unit Parallel Capacity (ND): 1759 kVA | Rating Modes: LD\/ND selectable | Inverter Rating Code: 12120 | Input: DC 430-780V (requires FR-CC2 converter) | Output Terminal: FM (pulse) \/ CA (0-10V analog), Pr.54 selectable | Cooling: Forced-air cooling | Protection: IP00 (open chassis) | Weight (per unit): 243 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604821794,"sku":"MEL-FRA800-A842-P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_cbde67b9-af47-4133-a76f-67139ac869fb.png?v=1790662240"},{"product_id":"mitsubishi-electric-freqrol-fr-a8-plug-in-option-boards-for-fr-a800-inverter-communication-i-o-vector-control-encoder-feedback","title":"Mitsubishi Electric FREQROL FR-A8 Plug-in Option Boards for FR-A800 Inverter (communication, I\/O, vector control, encoder feedback)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A8 series plug-in option boards for the FR-A800 inverter: fieldbus communication (CC-Link, CC-Link IE, PROFIBUS-DP, DeviceNet, SSCNET III), digital\/analog I\/O, relay output, vector control and encoder feedback.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eUp to 3 plug-in (1 communication) per inverter\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003ePlug-in option board\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AP plug-in option board for FR-A800 - Vector\/Orientation | Type: Plug-in option board | Function Group: Vector\/Orientation | Function: Vector control \u0026amp; orientation with encoder\/PLG (induction motor); spindle orientation \u0026amp; PLG feedback | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8APR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8APR plug-in option board for FR-A800 - Vector\/Orientation | Type: Plug-in option board | Function Group: Vector\/Orientation | Function: Vector control with encoder-equipped motor (induction\/PM) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8APS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8APS plug-in option board for FR-A800 - Vector\/Position | Type: Plug-in option board | Function Group: Vector\/Position | Function: Vector control with encoder (induction\/PM); point-table position control | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8APA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8APA plug-in option board for FR-A800 - Vector\/Orientation | Type: Plug-in option board | Function Group: Vector\/Orientation | Function: Vector control with encoder-equipped motor (induction\/PM) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8APD\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8APD plug-in option board for FR-A800 - PLG Pulse Output | Type: Plug-in option board | Function Group: PLG Pulse Output | Function: PLG pulse train division output | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AL plug-in option board for FR-A800 - Position\/Feedback | Type: Plug-in option board | Function Group: Position\/Feedback | Function: Vector control; position control via external pulse train; PLG feedback \u0026amp; pulse division | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AX plug-in option board for FR-A800 - Digital Input | Type: Plug-in option board | Function Group: Digital Input | Function: 16-bit digital input for frequency setting (BCD 3\/4-digit, binary 12\/16-bit) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AY\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AY plug-in option board for FR-A800 - Digital\/Analog Output | Type: Plug-in option board | Function Group: Digital\/Analog Output | Function: Open-collector digital output + 2x analog output (DC 0-20mA \/ 0-10V) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AR plug-in option board for FR-A800 - Relay Output | Type: Plug-in option board | Function Group: Relay Output | Function: Relay contact output (3 relay points) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AZ plug-in option board for FR-A800 - Analog\/Thermistor | Type: Plug-in option board | Function Group: Analog\/Thermistor | Function: Signed analog output (+\/-10V) + 16-bit high-resolution analog input + motor thermistor interface | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8AVP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8AVP plug-in option board for FR-A800 - Converter Switching | Type: Plug-in option board | Function Group: Converter Switching | Function: Inverter \/ high-power-factor converter switching; commercial-power phase synchronization switching | Applicable Inverter: FR-A842 separate converter type \/ 400V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8BC plug-in option board for FR-A800 - Converter Component | Type: Plug-in option board | Function Group: Converter Component | Function: Dedicated filter capacitor for high-power-factor converter conversion | Applicable Inverter: FR-A842 separate converter type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8BL1 plug-in option board for FR-A800 - Converter Component | Type: Plug-in option board | Function Group: Converter Component | Function: Dedicated filter reactor for high-power-factor converter conversion | Applicable Inverter: FR-A842 separate converter type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8BL2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8BL2 plug-in option board for FR-A800 - Converter Component | Type: Plug-in option board | Function Group: Converter Component | Function: Dedicated PWM control reactor for high-power-factor converter conversion | Applicable Inverter: FR-A842 separate converter type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8MC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8MC plug-in option board for FR-A800 - Converter Component | Type: Plug-in option board | Function Group: Converter Component | Function: Dedicated inrush current suppression unit for high-power-factor converter conversion | Applicable Inverter: FR-A842 separate converter type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8VPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8VPB plug-in option board for FR-A800 - Converter Component | Type: Plug-in option board | Function Group: Converter Component | Function: Phase detection transformer box (for converter switching \/ phase sync) | Applicable Inverter: FR-A842 separate converter type \/ 400V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8NCG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8NCG plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: CC-Link IE TSN network communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8NCE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8NCE plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: CC-Link IE Field Network communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8NC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8NC plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: CC-Link communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8NS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8NS plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: SSCNET III(\/H) communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8ND\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8ND plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: DeviceNet communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8NP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8NP plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: PROFIBUS-DP communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8NF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8NF plug-in option board for FR-A800 - Communication | Type: Plug-in option board | Function Group: Communication | Function: FL-remote communication | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8TR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8TR plug-in option board for FR-A800 - Control Terminal | Type: Plug-in option board | Function Group: Control Terminal | Function: Screw-type control circuit terminal block (ring-crimp terminal wiring) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8TP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8TP plug-in option board for FR-A800 - Control Terminal | Type: Plug-in option board | Function Group: Control Terminal | Function: Vector control terminal block with built-in DC24V PLG power (orientation\/PLG feedback\/vector\/pulse division) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-A8TAT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A8TAT plug-in option board for FR-A800 - Mounting Attachment | Type: Plug-in option board | Function Group: Mounting Attachment | Function: Control terminal block mounting compatibility attachment (FR-A700\/A500 to FR-A800) | Applicable Inverter: All FR-A800 models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396604952866,"sku":"MEL-FRA800-OPT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_67913e3f-6bfc-4edf-9c50-87ba3470282a.png?v=1790662243"},{"product_id":"mitsubishi-electric-freqrol-fr-a800-operation-panels-parameter-units-connection-cables","title":"Mitsubishi Electric FREQROL FR-A800 Operation Panels, Parameter Units \u0026 Connection Cables","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL FR-A800 peripheral accessories: LCD operation panels (FR-LU08, IP55 FR-LU08-01), parameter units (FR-PU07, battery-pack FR-PU07BB), connection cables (FR-CB20), USB and PLG cables.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eFor setup, monitoring and parameter configuration of FR-A800 inverters\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003cth\u003eCompatible\u003c\/th\u003e\n\u003ctd\u003eFR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-LU08\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-LU08 - Operation Panel for FR-A800 (LCD graphical operation panel) | Type: Operation Panel | Function: LCD graphical operation panel | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-LU08-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-LU08-01 - Operation Panel for FR-A800 (LCD graphical operation panel, IP55-compatible (excluding PU connector)) | Type: Operation Panel | Function: LCD graphical operation panel, IP55-compatible (excluding PU connector) | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-PU07\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-PU07 - Parameter Unit for FR-A800 (LCD interactive parameter unit (multi-language menu)) | Type: Parameter Unit | Function: LCD interactive parameter unit (multi-language menu) | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-PU07BB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-PU07BB - Parameter Unit for FR-A800 (Battery-pack parameter unit; parameter setting without inverter power) | Type: Parameter Unit | Function: Battery-pack parameter unit; parameter setting without inverter power | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-PU07BB-L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-PU07BB-L - Parameter Unit for FR-A800 (Battery-pack parameter unit (-L variant); parameter setting without inverter power) | Type: Parameter Unit | Function: Battery-pack parameter unit (-L variant); parameter setting without inverter power | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-CB201\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-CB201 - Cable for FR-A800 (Operation panel \/ parameter unit connection cable, 1 m) | Type: Cable | Function: Operation panel \/ parameter unit connection cable, 1 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-CB203\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-CB203 - Cable for FR-A800 (Operation panel \/ parameter unit connection cable, 3 m) | Type: Cable | Function: Operation panel \/ parameter unit connection cable, 3 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-CB205\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-CB205 - Cable for FR-A800 (Operation panel \/ parameter unit connection cable, 5 m) | Type: Cable | Function: Operation panel \/ parameter unit connection cable, 5 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMR-J3USBCBL3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMR-J3USBCBL3M - Cable for FR-A800 (USB cable (mini-B 5-pin to A connector), 3 m) | Type: Cable | Function: USB cable (mini-B 5-pin to A connector), 3 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-ADP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-ADP - Connector for FR-A800 (Connector joining operation panel (FR-DU08) and connection cable) | Type: Connector | Function: Connector joining operation panel (FR-DU08) and connection cable | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-V7CBL5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-V7CBL5M - Cable for FR-A800 (PLG cable for Mitsubishi vector-control motor SF-V5RU, 5 m) | Type: Cable | Function: PLG cable for Mitsubishi vector-control motor SF-V5RU, 5 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-V7CBL15M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-V7CBL15M - Cable for FR-A800 (PLG cable for Mitsubishi vector-control motor SF-V5RU, 15 m) | Type: Cable | Function: PLG cable for Mitsubishi vector-control motor SF-V5RU, 15 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-V7CBL30M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-V7CBL30M - Cable for FR-A800 (PLG cable for Mitsubishi vector-control motor SF-V5RU, 30 m) | Type: Cable | Function: PLG cable for Mitsubishi vector-control motor SF-V5RU, 30 m | Compatible: FR-A800 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605018402,"sku":"MEL-FRA800-ACC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0609-12_f96e90b1-ba6a-4b3e-90b2-d226d10e1193.png?v=1790662245"},{"product_id":"mitsubishi-electric-freqrol-fr-e720ex-three-phase-200v-compact-drive-unit-for-em-a-sensorless-servo-motor-0-1-3-7kw","title":"Mitsubishi Electric FR-E700EX FR-E720EX Sensorless Servo Drive Unit (3-Phase 200V, for MM-GKR)","description":"\u003cp class=\"ps-intro\"\u003eFR-E700EX sensorless servo drive unit FR-E720EX, 3-phase 200V, 0.1-0.75kW, for MM-GKR PM motors.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003ePM sensorless vector control (no encoder), point-table positioning (7 points), built-in RS-485, IP20 self-cooling\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload\u003c\/th\u003e\n\u003ctd\u003e150% 60s \/ 200% 3s (motor rated current basis, inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003ctd\u003ePM sensorless vector (high-freq superposition at low speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarrier\u003c\/th\u003e\n\u003ctd\u003e10kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositioning\u003c\/th\u003e\n\u003ctd\u003epoint-table 7 points, 5120 pulses\/rev, accuracy +\/-1.8 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003ebuilt-in RS-485 (Mitsubishi inverter \/ Modbus-RTU), option CC-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-ph 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eClosed IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eSelf-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720EX-0.1K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E700EX drive unit FR-E720EX 0.1kW, 3-ph 200V, for MM-GKR13 | Applied Motor: 0.1 kW | Rated Output Current: 0.8 A | Overload: 150% 60s \/ 200% 3s (motor rated current basis, inverse-time) | Control: PM sensorless vector (high-freq superposition at low speed) | Carrier: 10kHz | Positioning: point-table 7 points, 5120 pulses\/rev, accuracy +\/-1.8 deg | Communication: built-in RS-485 (Mitsubishi inverter \/ Modbus-RTU), option CC-Link | Input: 3-ph 200-240V 50\/60Hz | Enclosure: Closed IP20 | Cooling: Self-cooling | Mass: 0.5 kg | Depth (D): 80.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720EX-0.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E700EX drive unit FR-E720EX 0.2kW, 3-ph 200V, for MM-GKR23 | Applied Motor: 0.2 kW | Rated Output Current: 1.5 A | Overload: 150% 60s \/ 200% 3s (motor rated current basis, inverse-time) | Control: PM sensorless vector (high-freq superposition at low speed) | Carrier: 10kHz | Positioning: point-table 7 points, 5120 pulses\/rev, accuracy +\/-1.8 deg | Communication: built-in RS-485 (Mitsubishi inverter \/ Modbus-RTU), option CC-Link | Input: 3-ph 200-240V 50\/60Hz | Enclosure: Closed IP20 | Cooling: Self-cooling | Mass: 0.5 kg | Depth (D): 80.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720EX-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E700EX drive unit FR-E720EX 0.4kW, 3-ph 200V, for MM-GKR43 | Applied Motor: 0.4 kW | Rated Output Current: 3 A | Overload: 150% 60s \/ 200% 3s (motor rated current basis, inverse-time) | Control: PM sensorless vector (high-freq superposition at low speed) | Carrier: 10kHz | Positioning: point-table 7 points, 5120 pulses\/rev, accuracy +\/-1.8 deg | Communication: built-in RS-485 (Mitsubishi inverter \/ Modbus-RTU), option CC-Link | Input: 3-ph 200-240V 50\/60Hz | Enclosure: Closed IP20 | Cooling: Self-cooling | Mass: 0.7 kg | Depth (D): 112.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720EX-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E700EX drive unit FR-E720EX 0.75kW, 3-ph 200V, for MM-GKR73 | Applied Motor: 0.75 kW | Rated Output Current: 5 A | Overload: 150% 60s \/ 200% 3s (motor rated current basis, inverse-time) | Control: PM sensorless vector (high-freq superposition at low speed) | Carrier: 10kHz | Positioning: point-table 7 points, 5120 pulses\/rev, accuracy +\/-1.8 deg | Communication: built-in RS-485 (Mitsubishi inverter \/ Modbus-RTU), option CC-Link | Input: 3-ph 200-240V 50\/60Hz | Enclosure: Closed IP20 | Cooling: Self-cooling | Mass: 1.0 kg | Depth (D): 132.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605378850,"sku":"MEL-FRE700EX-E720EX","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-5.png?v=1790662249"},{"product_id":"mitsubishi-electric-fr-e820-compact-inverter-3-phase-200v-0-1-22kw-rs-485-standard","title":"Mitsubishi Electric FR-E820 Compact Inverter (3-Phase 200V, 0.1–22kW, RS-485 Standard)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E800 series compact inverter FR-E820, 3-phase 200–240V class, 0.1–22kW, with RS-485 communication and SIL2\/PLd functional safety.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial Rated Frequency\u003c\/th\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.1K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.1kW ND, Standard -1 | Capacity ND: 0.1 kW (code 0008) | Motor LD: 0.2 kW | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 1.3 A (1.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.1K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.1kW ND, Standard -5 | Capacity ND: 0.1 kW (code 0008) | Motor LD: 0.2 kW | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 1.3 A (1.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.2K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.2kW ND, Standard -1 | Capacity ND: 0.2 kW (code 0015) | Motor LD: 0.4 kW | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.0 A (1.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.2K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.2kW ND, Standard -5 | Capacity ND: 0.2 kW (code 0015) | Motor LD: 0.4 kW | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.0 A (1.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.4K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.4kW ND, Standard -1 | Capacity ND: 0.4 kW (code 0030) | Motor LD: 0.75 kW | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.7 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.4K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.4kW ND, Standard -5 | Capacity ND: 0.4 kW (code 0030) | Motor LD: 0.75 kW | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.7 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.75K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.75kW ND, Standard -1 | Capacity ND: 0.75 kW (code 0050) | Motor LD: 1.1 kW | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.0 A (5.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.75K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.75kW ND, Standard -5 | Capacity ND: 0.75 kW (code 0050) | Motor LD: 1.1 kW | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.0 A (5.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-1.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 1.5kW ND, Standard -1 | Capacity ND: 1.5 kW (code 0080) | Motor LD: 2.2 kW | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 9.6 A (8.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-1.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 1.5kW ND, Standard -5 | Capacity ND: 1.5 kW (code 0080) | Motor LD: 2.2 kW | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 9.6 A (8.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-2.2K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 2.2kW ND, Standard -1 | Capacity ND: 2.2 kW (code 0110) | Motor LD: 3.0 kW | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 12.0 A (10.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-2.2K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 2.2kW ND, Standard -5 | Capacity ND: 2.2 kW (code 0110) | Motor LD: 3.0 kW | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 12.0 A (10.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-3.7K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 3.7kW ND, Standard -1 | Capacity ND: 3.7 kW (code 0175) | Motor LD: 5.5 kW | Rated Current ND: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 19.6 A (16.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-3.7K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 3.7kW ND, Standard -5 | Capacity ND: 3.7 kW (code 0175) | Motor LD: 5.5 kW | Rated Current ND: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 19.6 A (16.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.0 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-5.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 5.5kW ND, Standard -1 | Capacity ND: 5.5 kW (code 0240) | Motor LD: 7.5 kW | Rated Current ND: 24.0 A (23.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 30.0 A (25.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.6 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-5.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 5.5kW ND, Standard -5 | Capacity ND: 5.5 kW (code 0240) | Motor LD: 7.5 kW | Rated Current ND: 24.0 A (23.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 30.0 A (25.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.6 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-7.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 7.5kW ND, Standard -1 | Capacity ND: 7.5 kW (code 0330) | Motor LD: 11.0 kW | Rated Current ND: 33.0 A (31.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 40.0 A (34.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.1 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-7.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 7.5kW ND, Standard -5 | Capacity ND: 7.5 kW (code 0330) | Motor LD: 11.0 kW | Rated Current ND: 33.0 A (31.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 40.0 A (34.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.1 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-11K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 11.0kW ND, Standard -1 | Capacity ND: 11.0 kW (code 0470) | Motor LD: 15.0 kW | Rated Current ND: 47.0 A (44.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 56.0 A (47.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 18.7 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-11K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 11.0kW ND, Standard -5 | Capacity ND: 11.0 kW (code 0470) | Motor LD: 15.0 kW | Rated Current ND: 47.0 A (44.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 56.0 A (47.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 18.7 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-15K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 15.0kW ND, Standard -1 | Capacity ND: 15.0 kW (code 0600) | Motor LD: 18.5 kW | Rated Current ND: 60.0 A (57.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 69.0 A (58.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 23.9 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.6 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-15K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 15.0kW ND, Standard -5 | Capacity ND: 15.0 kW (code 0600) | Motor LD: 18.5 kW | Rated Current ND: 60.0 A (57.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 69.0 A (58.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 23.9 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.6 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-18.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 18.5kW ND, Standard -1 | Capacity ND: 18.5 kW (code 0760) | Motor LD: 22.0 kW | Rated Current ND: 76.0 A (72.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 88.0 A (74.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 30.3 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-18.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 18.5kW ND, Standard -5 | Capacity ND: 18.5 kW (code 0760) | Motor LD: 22.0 kW | Rated Current ND: 76.0 A (72.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 88.0 A (74.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 30.3 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-22K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 22.0kW ND, Standard -1 | Capacity ND: 22.0 kW (code 0900) | Motor LD: 30.0 kW | Rated Current ND: 90.0 A (86.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 115.0 A (97.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 35.9 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-22K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 22.0kW ND, Standard -5 | Capacity ND: 22.0 kW (code 0900) | Motor LD: 30.0 kW | Rated Current ND: 90.0 A (86.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 115.0 A (97.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 35.9 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605509922,"sku":"MEL-FRE800-E820","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2.png?v=1790662251"},{"product_id":"mitsubishi-electric-fr-e820-compact-inverter-3-phase-200v-0-1-22kw-ethernet","title":"Mitsubishi Electric FR-E820 Compact Inverter (3-Phase 200V, 0.1–22kW, Ethernet)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E820 Ethernet-spec compact inverter, 3-phase 200–240V class, 0.1–22kW, with built-in Ethernet (CC-Link IE TSN, MODBUS\/TCP, EtherNet\/IP, PROFINET per protocol group) and SIL2\/PLd functional safety.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSink (kW model)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.1KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.1kW ND, Ethernet EPA | Capacity ND: 0.1 kW (code 0008) | Motor LD: 0.2 kW | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 1.3 A (1.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.1KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.1kW ND, Ethernet EPB | Capacity ND: 0.1 kW (code 0008) | Motor LD: 0.2 kW | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 1.3 A (1.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.2KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.2kW ND, Ethernet EPA | Capacity ND: 0.2 kW (code 0015) | Motor LD: 0.4 kW | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.0 A (1.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.2KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.2kW ND, Ethernet EPB | Capacity ND: 0.2 kW (code 0015) | Motor LD: 0.4 kW | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.0 A (1.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.4KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.4kW ND, Ethernet EPA | Capacity ND: 0.4 kW (code 0030) | Motor LD: 0.75 kW | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.7 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.4KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.4kW ND, Ethernet EPB | Capacity ND: 0.4 kW (code 0030) | Motor LD: 0.75 kW | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.7 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.75KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.75kW ND, Ethernet EPA | Capacity ND: 0.75 kW (code 0050) | Motor LD: 1.1 kW | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.0 A (5.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.75KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.75kW ND, Ethernet EPB | Capacity ND: 0.75 kW (code 0050) | Motor LD: 1.1 kW | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.0 A (5.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-1.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 1.5kW ND, Ethernet EPA | Capacity ND: 1.5 kW (code 0080) | Motor LD: 2.2 kW | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 9.6 A (8.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-1.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 1.5kW ND, Ethernet EPB | Capacity ND: 1.5 kW (code 0080) | Motor LD: 2.2 kW | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 9.6 A (8.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-2.2KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 2.2kW ND, Ethernet EPA | Capacity ND: 2.2 kW (code 0110) | Motor LD: 3.0 kW | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 12.0 A (10.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-2.2KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 2.2kW ND, Ethernet EPB | Capacity ND: 2.2 kW (code 0110) | Motor LD: 3.0 kW | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 12.0 A (10.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-3.7KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 3.7kW ND, Ethernet EPA | Capacity ND: 3.7 kW (code 0175) | Motor LD: 5.5 kW | Rated Current ND: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 19.6 A (16.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-3.7KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 3.7kW ND, Ethernet EPB | Capacity ND: 3.7 kW (code 0175) | Motor LD: 5.5 kW | Rated Current ND: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 19.6 A (16.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.0 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-5.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 5.5kW ND, Ethernet EPA | Capacity ND: 5.5 kW (code 0240) | Motor LD: 7.5 kW | Rated Current ND: 24.0 A (23.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 30.0 A (25.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.6 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-5.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 5.5kW ND, Ethernet EPB | Capacity ND: 5.5 kW (code 0240) | Motor LD: 7.5 kW | Rated Current ND: 24.0 A (23.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 30.0 A (25.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.6 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-7.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 7.5kW ND, Ethernet EPA | Capacity ND: 7.5 kW (code 0330) | Motor LD: 11.0 kW | Rated Current ND: 33.0 A (31.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 40.0 A (34.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.1 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-7.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 7.5kW ND, Ethernet EPB | Capacity ND: 7.5 kW (code 0330) | Motor LD: 11.0 kW | Rated Current ND: 33.0 A (31.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 40.0 A (34.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.1 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-11KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 11.0kW ND, Ethernet EPA | Capacity ND: 11.0 kW (code 0470) | Motor LD: 15.0 kW | Rated Current ND: 47.0 A (44.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 56.0 A (47.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 18.7 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-11KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 11.0kW ND, Ethernet EPB | Capacity ND: 11.0 kW (code 0470) | Motor LD: 15.0 kW | Rated Current ND: 47.0 A (44.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 56.0 A (47.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 18.7 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-15KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 15.0kW ND, Ethernet EPA | Capacity ND: 15.0 kW (code 0600) | Motor LD: 18.5 kW | Rated Current ND: 60.0 A (57.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 69.0 A (58.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 23.9 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.6 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-15KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 15.0kW ND, Ethernet EPB | Capacity ND: 15.0 kW (code 0600) | Motor LD: 18.5 kW | Rated Current ND: 60.0 A (57.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 69.0 A (58.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 23.9 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.6 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-18.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 18.5kW ND, Ethernet EPA | Capacity ND: 18.5 kW (code 0760) | Motor LD: 22.0 kW | Rated Current ND: 76.0 A (72.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 88.0 A (74.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 30.3 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-18.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 18.5kW ND, Ethernet EPB | Capacity ND: 18.5 kW (code 0760) | Motor LD: 22.0 kW | Rated Current ND: 76.0 A (72.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 88.0 A (74.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 30.3 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-22KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 22.0kW ND, Ethernet EPA | Capacity ND: 22.0 kW (code 0900) | Motor LD: 30.0 kW | Rated Current ND: 90.0 A (86.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 115.0 A (97.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 35.9 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-22KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 22.0kW ND, Ethernet EPB | Capacity ND: 22.0 kW (code 0900) | Motor LD: 30.0 kW | Rated Current ND: 90.0 A (86.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 115.0 A (97.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 35.9 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605640994,"sku":"MEL-FRE800-E820-ETH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_61c9b9cf-f42d-490a-81bd-11586459eeef.png?v=1790662251"},{"product_id":"mitsubishi-electric-fr-e820-compact-inverter-3-phase-200v-0-1-22kw-safety-communication-sil3-ple","title":"Mitsubishi Electric FR-E820 Compact Inverter (3-Phase 200V, 0.1–22kW, Safety Communication SIL3\/PLe)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E820 safety-communication-spec compact inverter, 3-phase 200–240V class, 0.1–22kW, with Ethernet and SIL3\/PLe functional safety over network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eMade-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.1KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.1kW ND, Safety SCEPA | Capacity ND: 0.1 kW (code 0008) | Motor LD: 0.2 kW | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 1.3 A (1.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.1KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.1kW ND, Safety SCEPB | Capacity ND: 0.1 kW (code 0008) | Motor LD: 0.2 kW | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 1.3 A (1.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.2KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.2kW ND, Safety SCEPA | Capacity ND: 0.2 kW (code 0015) | Motor LD: 0.4 kW | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.0 A (1.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.2KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.2kW ND, Safety SCEPB | Capacity ND: 0.2 kW (code 0015) | Motor LD: 0.4 kW | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.0 A (1.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.4KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.4kW ND, Safety SCEPA | Capacity ND: 0.4 kW (code 0030) | Motor LD: 0.75 kW | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.7 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.4KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.4kW ND, Safety SCEPB | Capacity ND: 0.4 kW (code 0030) | Motor LD: 0.75 kW | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.7 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.75KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.75kW ND, Safety SCEPA | Capacity ND: 0.75 kW (code 0050) | Motor LD: 1.1 kW | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.0 A (5.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-0.75KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 0.75kW ND, Safety SCEPB | Capacity ND: 0.75 kW (code 0050) | Motor LD: 1.1 kW | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.0 A (5.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-1.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 1.5kW ND, Safety SCEPA | Capacity ND: 1.5 kW (code 0080) | Motor LD: 2.2 kW | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 9.6 A (8.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-1.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 1.5kW ND, Safety SCEPB | Capacity ND: 1.5 kW (code 0080) | Motor LD: 2.2 kW | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 9.6 A (8.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-2.2KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 2.2kW ND, Safety SCEPA | Capacity ND: 2.2 kW (code 0110) | Motor LD: 3.0 kW | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 12.0 A (10.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-2.2KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 2.2kW ND, Safety SCEPB | Capacity ND: 2.2 kW (code 0110) | Motor LD: 3.0 kW | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 12.0 A (10.2 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-3.7KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 3.7kW ND, Safety SCEPA | Capacity ND: 3.7 kW (code 0175) | Motor LD: 5.5 kW | Rated Current ND: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 19.6 A (16.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-3.7KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 3.7kW ND, Safety SCEPB | Capacity ND: 3.7 kW (code 0175) | Motor LD: 5.5 kW | Rated Current ND: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Rated Current LD: 19.6 A (16.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-5.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 5.5kW ND, Safety SCEPA | Capacity ND: 5.5 kW (code 0240) | Motor LD: 7.5 kW | Rated Current ND: 24.0 A (23.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 30.0 A (25.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.6 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-5.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 5.5kW ND, Safety SCEPB | Capacity ND: 5.5 kW (code 0240) | Motor LD: 7.5 kW | Rated Current ND: 24.0 A (23.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 30.0 A (25.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.6 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-7.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 7.5kW ND, Safety SCEPA | Capacity ND: 7.5 kW (code 0330) | Motor LD: 11.0 kW | Rated Current ND: 33.0 A (31.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 40.0 A (34.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.1 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-7.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 7.5kW ND, Safety SCEPB | Capacity ND: 7.5 kW (code 0330) | Motor LD: 11.0 kW | Rated Current ND: 33.0 A (31.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 40.0 A (34.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.1 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 3.3 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-11KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 11.0kW ND, Safety SCEPA | Capacity ND: 11.0 kW (code 0470) | Motor LD: 15.0 kW | Rated Current ND: 47.0 A (44.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 56.0 A (47.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 18.7 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-11KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 11.0kW ND, Safety SCEPB | Capacity ND: 11.0 kW (code 0470) | Motor LD: 15.0 kW | Rated Current ND: 47.0 A (44.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 56.0 A (47.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 18.7 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-15KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 15.0kW ND, Safety SCEPA | Capacity ND: 15.0 kW (code 0600) | Motor LD: 18.5 kW | Rated Current ND: 60.0 A (57.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 69.0 A (58.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 23.9 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.6 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-15KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 15.0kW ND, Safety SCEPB | Capacity ND: 15.0 kW (code 0600) | Motor LD: 18.5 kW | Rated Current ND: 60.0 A (57.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 69.0 A (58.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 23.9 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 5.6 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-18.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 18.5kW ND, Safety SCEPA | Capacity ND: 18.5 kW (code 0760) | Motor LD: 22.0 kW | Rated Current ND: 76.0 A (72.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 88.0 A (74.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 30.3 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-18.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 18.5kW ND, Safety SCEPB | Capacity ND: 18.5 kW (code 0760) | Motor LD: 22.0 kW | Rated Current ND: 76.0 A (72.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 88.0 A (74.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 30.3 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-22KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 22.0kW ND, Safety SCEPA | Capacity ND: 22.0 kW (code 0900) | Motor LD: 30.0 kW | Rated Current ND: 90.0 A (86.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 115.0 A (97.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 35.9 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820-22KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820 compact inverter, 22.0kW ND, Safety SCEPB | Capacity ND: 22.0 kW (code 0900) | Motor LD: 30.0 kW | Rated Current ND: 90.0 A (86.0 A at 2kHz+ low-noise PWM) | Rated Current LD: 115.0 A (97.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 35.9 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605706530,"sku":"MEL-FRE800-E820-SCE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_0cab3c88-f6fe-48ef-bd43-dcce25e0c524.png?v=1790662253"},{"product_id":"mitsubishi-electric-fr-e840-compact-inverter-3-phase-400v-0-4-22kw-rs-485-standard","title":"Mitsubishi Electric FR-E840 Compact Inverter (3-Phase 400V, 0.4–22kW, RS-485 Standard)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E800 series compact inverter FR-E840, 3-phase 380–480V class, 0.4–22kW, with RS-485 communication and SIL2\/PLd functional safety.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial Rated Frequency\u003c\/th\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Standard -1 | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Standard -5 | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Standard -1 | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Standard -5 | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Standard -1 | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Standard -5 | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Standard -1 | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Standard -5 | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Standard -1 | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Standard -5 | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Standard -1 | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Standard -5 | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Standard -1 | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Standard -5 | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Standard -1 | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Standard -5 | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Standard -1 | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Standard -5 | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Standard -1 | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Standard -5 | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Standard -1 | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22K-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Standard -5 | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Standard -5 | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605804834,"sku":"MEL-FRE800-E840","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_d87317e8-bce0-43dc-bd27-a2fa315d6cd9.png?v=1790662254"},{"product_id":"mitsubishi-electric-fr-e840-compact-inverter-3-phase-400v-0-4-22kw-ethernet","title":"Mitsubishi Electric FR-E840 Compact Inverter (3-Phase 400V, 0.4–22kW, Ethernet)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E840 Ethernet-spec compact inverter, 3-phase 380–480V class, 0.4–22kW, with built-in Ethernet (CC-Link IE TSN, MODBUS\/TCP, EtherNet\/IP, PROFINET per protocol group) and SIL2\/PLd functional safety.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSink (kW model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Ethernet EPA | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Ethernet EPB | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Ethernet EPA | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Ethernet EPB | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Ethernet EPA | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Ethernet EPB | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Ethernet EPA | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Ethernet EPB | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Ethernet EPA | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Ethernet EPB | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Ethernet EPA | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Ethernet EPB | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Ethernet EPA | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Ethernet EPB | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Ethernet EPA | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Ethernet EPB | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Ethernet EPA | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Ethernet EPB | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Ethernet EPA | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Ethernet EPB | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Ethernet EPA | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22KEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Ethernet EPB | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Ethernet EPB | Communication: Ethernet + safety SIL2\/PLd, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605837602,"sku":"MEL-FRE800-E840-ETH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_9cfa6d26-ad61-4741-8720-54068ac2b2c8.png?v=1790662255"},{"product_id":"mitsubishi-electric-fr-e840-compact-inverter-3-phase-400v-0-4-22kw-safety-communication-sil3-ple","title":"Mitsubishi Electric FR-E840 Compact Inverter (3-Phase 400V, 0.4–22kW, Safety Communication SIL3\/PLe)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E840 safety-communication-spec compact inverter, 3-phase 380–480V class, 0.4–22kW, with Ethernet and SIL3\/PLe functional safety over network.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating (model name = ND), overload 150% 60s \/ 200% 3s (ND) or 120% 60s \/ 150% 3s (LD) at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\n\u003cli\u003eOptional circuit board coating (-60\/-06) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eMade-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Safety SCEPA | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.4KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.4kW ND, Safety SCEPB | Capacity ND: 0.4 kW (code 0016) | Motor LD: 0.75 kW | Rated Current ND: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 2.1 A (1.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Safety SCEPA | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-0.75KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 0.75kW ND, Safety SCEPB | Capacity ND: 0.75 kW (code 0026) | Motor LD: 1.5 kW | Rated Current ND: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Rated Current LD: 3.5 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.2 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Safety SCEPA | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-1.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 1.5kW ND, Safety SCEPB | Capacity ND: 1.5 kW (code 0040) | Motor LD: 2.2 kW | Rated Current ND: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Rated Current LD: 5.5 A (4.7 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Safety SCEPA | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-2.2KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 2.2kW ND, Safety SCEPB | Capacity ND: 2.2 kW (code 0060) | Motor LD: 3.0 kW | Rated Current ND: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Rated Current LD: 6.9 A (5.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.6 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Safety SCEPA | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-3.7KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 3.7kW ND, Safety SCEPB | Capacity ND: 3.7 kW (code 0095) | Motor LD: 5.5 kW | Rated Current ND: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Rated Current LD: 11.1 A (9.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 7.2 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Safety SCEPA | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-5.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 5.5kW ND, Safety SCEPB | Capacity ND: 5.5 kW (code 0120) | Motor LD: 7.5 kW | Rated Current ND: 12.0 A | Rated Current LD: 17.5 A (14.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.1 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Safety SCEPA | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-7.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 7.5kW ND, Safety SCEPB | Capacity ND: 7.5 kW (code 0170) | Motor LD: 11.0 kW | Rated Current ND: 17.0 A | Rated Current LD: 23.0 A (19.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 13.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Safety SCEPA | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-11KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 11.0kW ND, Safety SCEPB | Capacity ND: 11.0 kW (code 0230) | Motor LD: 15.0 kW | Rated Current ND: 23.0 A | Rated Current LD: 35.0 A (29.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 17.5 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.8 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Safety SCEPA | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-15KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 15.0kW ND, Safety SCEPB | Capacity ND: 15.0 kW (code 0300) | Motor LD: 18.5 kW | Rated Current ND: 30.0 A | Rated Current LD: 41.0 A (34.9 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 22.9 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 4.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Safety SCEPA | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-18.5KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 18.5kW ND, Safety SCEPB | Capacity ND: 18.5 kW (code 0380) | Motor LD: 22.0 kW | Rated Current ND: 38.0 A | Rated Current LD: 45.0 A (38.3 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 29.0 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22KSCEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Safety SCEPA | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Safety SCEPA | Communication: Ethernet + safety SIL3\/PLe, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E840-22KSCEPB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E840 compact inverter, 22.0kW ND, Safety SCEPB | Capacity ND: 22.0 kW (code 0440) | Motor LD: 30.0 kW | Rated Current ND: 44.0 A | Rated Current LD: 60.0 A (51.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 33.5 kVA | Spec Type: Safety SCEPB | Communication: Ethernet + safety SIL3\/PLe, Protocol Group B (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, PROFINET) | Initial Rated Frequency: 50Hz | Control Logic: Source | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 11.0 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605870370,"sku":"MEL-FRE800-E840-SCE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_c781d665-224f-432c-903b-f576cb3b3653.png?v=1790662257"},{"product_id":"mitsubishi-electric-fr-e860-compact-inverter-3-phase-575v-0-75-7-5kw","title":"Mitsubishi Electric FR-E860 Compact Inverter (3-Phase 575V, 0.75–7.5kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E800 series compact inverter FR-E860, 3-phase 525–600V class (575V 60Hz input), 0.75–7.5kW, in RS-485 standard and Ethernet specifications with functional safety.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDual LD\/ND rating, model names use rated-current codes with -60 coated circuit boards; all models made-to-order\u003c\/li\u003e\n\u003cli\u003eOverload 150% 60s \/ 200% 3s (ND), open type IP20\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial Rated Frequency\u003c\/th\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Logic\u003c\/th\u003e\n\u003ctd\u003eSink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eMade-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0017-5-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 0.75kW ND, Standard -5-60 (coated board) | Capacity ND: 0.75 kW (code 0017) | Motor LD: 1.5 kW | Rated Current ND: 1.7 A | Rated Current LD: 2.5 A (2.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.7 kVA | Spec Type: Standard -5-60 (coated board) | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0017EPA-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 0.75kW ND, Ethernet EPA-60 (coated board) | Capacity ND: 0.75 kW (code 0017) | Motor LD: 1.5 kW | Rated Current ND: 1.7 A | Rated Current LD: 2.5 A (2.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.7 kVA | Spec Type: Ethernet EPA-60 (coated board) | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0027-5-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 1.5kW ND, Standard -5-60 (coated board) | Capacity ND: 1.5 kW (code 0027) | Motor LD: 2.2 kW | Rated Current ND: 2.7 A | Rated Current LD: 3.6 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.7 kVA | Spec Type: Standard -5-60 (coated board) | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0027EPA-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 1.5kW ND, Ethernet EPA-60 (coated board) | Capacity ND: 1.5 kW (code 0027) | Motor LD: 2.2 kW | Rated Current ND: 2.7 A | Rated Current LD: 3.6 A (3.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.7 kVA | Spec Type: Ethernet EPA-60 (coated board) | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0040-5-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 2.2kW ND, Standard -5-60 (coated board) | Capacity ND: 2.2 kW (code 0040) | Motor LD: 3.7 kW | Rated Current ND: 4.0 A | Rated Current LD: 5.6 A (4.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.0 kVA | Spec Type: Standard -5-60 (coated board) | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0040EPA-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 2.2kW ND, Ethernet EPA-60 (coated board) | Capacity ND: 2.2 kW (code 0040) | Motor LD: 3.7 kW | Rated Current ND: 4.0 A | Rated Current LD: 5.6 A (4.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.0 kVA | Spec Type: Ethernet EPA-60 (coated board) | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.9 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0061-5-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 3.7kW ND, Standard -5-60 (coated board) | Capacity ND: 3.7 kW (code 0061) | Motor LD: 5.5 kW | Rated Current ND: 6.1 A | Rated Current LD: 8.2 A (7.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 6.1 kVA | Spec Type: Standard -5-60 (coated board) | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0061EPA-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 3.7kW ND, Ethernet EPA-60 (coated board) | Capacity ND: 3.7 kW (code 0061) | Motor LD: 5.5 kW | Rated Current ND: 6.1 A | Rated Current LD: 8.2 A (7.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 6.1 kVA | Spec Type: Ethernet EPA-60 (coated board) | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0090-5-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 5.5kW ND, Standard -5-60 (coated board) | Capacity ND: 5.5 kW (code 0090) | Motor LD: 7.5 kW | Rated Current ND: 9.0 A | Rated Current LD: 11.0 A (9.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.0 kVA | Spec Type: Standard -5-60 (coated board) | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0090EPA-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 5.5kW ND, Ethernet EPA-60 (coated board) | Capacity ND: 5.5 kW (code 0090) | Motor LD: 7.5 kW | Rated Current ND: 9.0 A | Rated Current LD: 11.0 A (9.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 9.0 kVA | Spec Type: Ethernet EPA-60 (coated board) | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0120-5-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 7.5kW ND, Standard -5-60 (coated board) | Capacity ND: 7.5 kW (code 0120) | Motor LD: 11.0 kW | Rated Current ND: 12.0 A | Rated Current LD: 16.0 A (13.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 12.0 kVA | Spec Type: Standard -5-60 (coated board) | Communication: RS-485 + safety SIL2\/PLd, monitor: Voltage (AM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E860-0120EPA-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E860 compact inverter, 7.5kW ND, Ethernet EPA-60 (coated board) | Capacity ND: 7.5 kW (code 0120) | Motor LD: 11.0 kW | Rated Current ND: 12.0 A | Rated Current LD: 16.0 A (13.6 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 12.0 kVA | Spec Type: Ethernet EPA-60 (coated board) | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 2.4 kg | Availability: Made-to-order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396605968674,"sku":"MEL-FRE800-E860","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_a9093504-6f9c-4ef4-9a51-4e462166a84c.png?v=1790662258"},{"product_id":"mitsubishi-electric-fr-e820s-compact-inverter-single-phase-200v-input-0-1-2-2kw","title":"Mitsubishi Electric FR-E820S Compact Inverter (Single-Phase 200V Input, 0.1–2.2kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi Electric FR-E800 series compact inverter FR-E820S, single-phase 200–240V input \/ 3-phase 200–240V output, 0.1–2.2kW (ND rating), in RS-485 standard and Ethernet specifications with SIL2\/PLd functional safety.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eOverload 150% 60s \/ 200% 3s at 50°C, Soft-PWM control, open type IP20\u003c\/li\u003e\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial Rated Frequency\u003c\/th\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eStocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.1K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.1kW ND, Standard -1 | Capacity ND: 0.1 kW (code 0008) | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.1KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.1kW ND, Ethernet EPA | Capacity ND: 0.1 kW (code 0008) | Rated Current ND: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.3 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.2K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.2kW ND, Standard -1 | Capacity ND: 0.2 kW (code 0015) | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.2KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.2kW ND, Ethernet EPA | Capacity ND: 0.2 kW (code 0015) | Rated Current ND: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 0.6 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: None | Max Brake Torque ND: 150% | Cooling: Self-cooling | Weight: 0.5 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.4K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.4kW ND, Standard -1 | Capacity ND: 0.4 kW (code 0030) | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.4KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.4kW ND, Ethernet EPA | Capacity ND: 0.4 kW (code 0030) | Rated Current ND: 3.0 A (2.5 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 1.2 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 0.8 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.75K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.75kW ND, Standard -1 | Capacity ND: 0.75 kW (code 0050) | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.3 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-0.75KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 0.75kW ND, Ethernet EPA | Capacity ND: 0.75 kW (code 0050) | Rated Current ND: 5.0 A (4.1 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 2.0 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 100% | Cooling: Self-cooling | Weight: 1.3 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-1.5K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 1.5kW ND, Standard -1 | Capacity ND: 1.5 kW (code 0080) | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-1.5KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 1.5kW ND, Ethernet EPA | Capacity ND: 1.5 kW (code 0080) | Rated Current ND: 8.0 A (7.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 3.2 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 50% | Cooling: Forced air cooling | Weight: 1.4 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-2.2K-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 2.2kW ND, Standard -1 | Capacity ND: 2.2 kW (code 0110) | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Standard -1 | Communication: RS-485 + safety SIL2\/PLd, monitor: Pulse (FM) | Initial Rated Frequency: 60Hz | Control Logic: Sink | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.9 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E820S-2.2KEPA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E820S compact inverter, single-phase 200V input, 2.2kW ND, Ethernet EPA | Capacity ND: 2.2 kW (code 0110) | Rated Current ND: 11.0 A (10.0 A at 2kHz+ low-noise PWM) | Rated Capacity ND: 4.4 kVA | Spec Type: Ethernet EPA | Communication: Ethernet + safety SIL2\/PLd, Protocol Group A (CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS\/TCP, EtherNet\/IP, BACnet\/IP) | Initial Rated Frequency: 60Hz | Control Logic: Sink (kW model) | Brake Transistor: Built-in | Max Brake Torque ND: 20% | Cooling: Forced air cooling | Weight: 1.9 kg | Availability: Stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606001442,"sku":"MEL-FRE800-E820S","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-2_7321db7a-54a4-4a20-b594-24f35d18579e.png?v=1790662259"},{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-200v-vfd-standard-fm-terminal-0-1-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 200V VFD (Standard FM terminal, 0.1–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStandard FM terminal\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e170-264V (DC240-373V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP20 (enclosed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eRS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.1K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.1K Standard FM terminal, 0.1kW | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.4 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.2K Standard FM terminal, 0.2kW | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.8 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.4K Standard FM terminal, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 0.7 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.75K Standard FM terminal, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.0 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-1.5K Standard FM terminal, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.2 kVA | Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 50% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-2.2K Standard FM terminal, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.4 kVA | Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-3.7K Standard FM terminal, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.0 kVA | Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 9 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.7 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-5.5K Standard FM terminal, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.5 kVA | Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-7.5K Standard FM terminal, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.1 kVA | Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-11K Standard FM terminal, 11kW | Applied Motor: 11 kW | Rated Capacity: 18.7 kVA | Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-15K Standard FM terminal, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.9 kVA | Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606034210,"sku":"MEL-FRE700-E720-STD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3.png?v=1790662261"},{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-200v-vfd-safety-stop-compatible-0-1-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 200V VFD (Safety Stop compatible, 0.1–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSafety Stop compatible\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e170-264V (DC240-373V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP20 (enclosed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eRS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003eEN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.1KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.1KSC Safety Stop compatible, 0.1kW | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.4 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.2KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.2KSC Safety Stop compatible, 0.2kW | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.8 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.4KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.4KSC Safety Stop compatible, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 0.7 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.75KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.75KSC Safety Stop compatible, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.0 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-1.5KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-1.5KSC Safety Stop compatible, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.2 kVA | Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 50% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-2.2KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-2.2KSC Safety Stop compatible, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.4 kVA | Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-3.7KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-3.7KSC Safety Stop compatible, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.0 kVA | Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 9 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.7 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-5.5KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-5.5KSC Safety Stop compatible, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.5 kVA | Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-7.5KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-7.5KSC Safety Stop compatible, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.1 kVA | Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-11KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-11KSC Safety Stop compatible, 11kW | Applied Motor: 11 kW | Rated Capacity: 18.7 kVA | Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-15KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-15KSC Safety Stop compatible, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.9 kVA | Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606066978,"sku":"MEL-FRE700-E720-SC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3_74d4015a-c30a-48e3-bc06-5117cbcee0f4.png?v=1790662262"},{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-200v-vfd-fl-remote-communication-0-1-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 200V VFD (FL-remote communication, 0.1–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFL-remote communication\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e170-264V (DC240-373V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP00 (open type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eFL-remote network (dedicated connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003eS1\/S2 dual-channel input (Safety Monitor 2 output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.1KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.1KNF FL-remote communication, 0.1kW | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.4 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.2KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.2KNF FL-remote communication, 0.2kW | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.8 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.4KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.4KNF FL-remote communication, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 0.7 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.75KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.75KNF FL-remote communication, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 1.0 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-1.5KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-1.5KNF FL-remote communication, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.2 kVA | Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 50% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-2.2KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-2.2KNF FL-remote communication, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.4 kVA | Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-3.7KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-3.7KNF FL-remote communication, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.0 kVA | Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 9 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 1.7 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-5.5KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-5.5KNF FL-remote communication, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.5 kVA | Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-7.5KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-7.5KNF FL-remote communication, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.1 kVA | Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-11KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-11KNF FL-remote communication, 11kW | Applied Motor: 11 kW | Rated Capacity: 18.7 kVA | Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-15KNF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-15KNF FL-remote communication, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.9 kVA | Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: FL-remote network (dedicated connector) | Safety Function: S1\/S2 dual-channel input (Safety Monitor 2 output) | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: FL-remote communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606165282,"sku":"MEL-FRE700-E720-NF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3_eabeae05-db92-4232-8fea-0762e235b655.png?v=1790662263"},{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-200v-vfd-cc-link-communication-0-1-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 200V VFD (CC-Link communication, 0.1–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eCC-Link communication\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 200-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 200-240V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e170-264V (DC240-373V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP00 (open type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eCC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003eS1\/S2 dual-channel input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.1KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.1KNC CC-Link communication, 0.1kW | Applied Motor: 0.1 kW | Rated Capacity: 0.3 kVA | Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.4 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.2KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.2KNC CC-Link communication, 0.2kW | Applied Motor: 0.2 kW | Rated Capacity: 0.6 kVA | Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 150% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 0.8 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: None (no brake resistor connection) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 0.5 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.4KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.4KNC CC-Link communication, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 0.7 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-0.75KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-0.75KNC CC-Link communication, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 100% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 1.0 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-1.5KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-1.5KNC CC-Link communication, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.2 kVA | Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 50% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-2.2KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-2.2KNC CC-Link communication, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.4 kVA | Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-3.7KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-3.7KNC CC-Link communication, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.0 kVA | Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 9 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 1.7 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-5.5KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-5.5KNC CC-Link communication, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.5 kVA | Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-7.5KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-7.5KNC CC-Link communication, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.1 kVA | Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 4.3 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-11KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-11KNC CC-Link communication, 11kW | Applied Motor: 11 kW | Rated Capacity: 18.7 kVA | Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E720-15KNC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E720-15KNC CC-Link communication, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.9 kVA | Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 200-240V | Regenerative Torque: 20% | Input: 3-phase 200-240V 50\/60Hz | Input Voltage Range: 170-264V (DC240-373V) | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP00 (open type) | Communication: CC-Link (2-port A6CON-L5P \/ 35505-6000-B0M GF) | Safety Function: S1\/S2 dual-channel input | Standards: UL, cUL, CE | Mass: 6.5 kg | Spec Type: CC-Link communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606198050,"sku":"MEL-FRE700-E720-NC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3_f5ca5dad-43a9-4a3a-ae84-eec292ab4ae5.png?v=1790662265"},{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-400v-vfd-standard-fm-terminal-0-4-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 400V VFD (Standard FM terminal, 0.4–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStandard FM terminal\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 380-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 380-480V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e325-528V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (0.4K and above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP20 (enclosed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eRS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-0.4K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-0.4K Standard FM terminal, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 100% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-0.75K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-0.75K Standard FM terminal, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 100% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-1.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-1.5K Standard FM terminal, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.0 kVA | Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 50% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-2.2K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-2.2K Standard FM terminal, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.6 kVA | Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-3.7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-3.7K Standard FM terminal, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.2 kVA | Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 9.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-5.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-5.5K Standard FM terminal, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.1 kVA | Rated Current: 12 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 3.2 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-7.5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-7.5K Standard FM terminal, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.0 kVA | Rated Current: 17 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 3.2 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-11K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-11K Standard FM terminal, 11kW | Applied Motor: 11 kW | Rated Capacity: 17.5 kVA | Rated Current: 23 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 6.0 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-15K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-15K Standard FM terminal, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.0 kVA | Rated Current: 30 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: — | Standards: UL, cUL, CE | Mass: 6.0 kg | Spec Type: Standard FM terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606263586,"sku":"MEL-FRE700-E740-STD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3_cd84eba5-5a30-433e-a10c-af49c555bf12.png?v=1790662266"},{"product_id":"mitsubishi-electric-freqrol-e700-3-phase-400v-vfd-safety-stop-compatible-0-4-15kw","title":"Mitsubishi Electric FREQROL-E700 3-Phase 400V VFD (Safety Stop compatible, 0.4–15kW)","description":"\u003cp class=\"ps-intro\"\u003eMitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSafety Stop compatible\u003c\/li\u003e\n\u003cli\u003eAdvanced magnetic flux vector control with 200%\/0.5Hz starting torque (≤3.7K)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL\/CE compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Current\u003c\/th\u003e\n\u003ctd\u003e150% 60s, 200% 3s (inverse-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e3-Phase 380-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e3-phase 380-480V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage Range\u003c\/th\u003e\n\u003ctd\u003e325-528V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Tolerance\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Method\u003c\/th\u003e\n\u003ctd\u003eV\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Frequency\u003c\/th\u003e\n\u003ctd\u003e400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePWM Carrier Frequency\u003c\/th\u003e\n\u003ctd\u003e0.7–14.5 kHz (Soft-PWM selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrake Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (0.4K and above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Structure\u003c\/th\u003e\n\u003ctd\u003eIP20 (enclosed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eRS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Function\u003c\/th\u003e\n\u003ctd\u003eEN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-0.4KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-0.4KSC Safety Stop compatible, 0.4kW | Applied Motor: 0.4 kW | Rated Capacity: 1.2 kVA | Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 100% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 1.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-0.75KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-0.75KSC Safety Stop compatible, 0.75kW | Applied Motor: 0.75 kW | Rated Capacity: 2.0 kVA | Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 100% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 2.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Self-cooled | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.4 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-1.5KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-1.5KSC Safety Stop compatible, 1.5kW | Applied Motor: 1.5 kW | Rated Capacity: 3.0 kVA | Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 50% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 4.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-2.2KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-2.2KSC Safety Stop compatible, 2.2kW | Applied Motor: 2.2 kW | Rated Capacity: 4.6 kVA | Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 5.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-3.7KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-3.7KSC Safety Stop compatible, 3.7kW | Applied Motor: 3.7 kW | Rated Capacity: 7.2 kVA | Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 9.5 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 1.9 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-5.5KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-5.5KSC Safety Stop compatible, 5.5kW | Applied Motor: 5.5 kW | Rated Capacity: 9.1 kVA | Rated Current: 12 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 12 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 3.2 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-7.5KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-7.5KSC Safety Stop compatible, 7.5kW | Applied Motor: 7.5 kW | Rated Capacity: 13.0 kVA | Rated Current: 17 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 17 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 3.2 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-11KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-11KSC Safety Stop compatible, 11kW | Applied Motor: 11 kW | Rated Capacity: 17.5 kVA | Rated Current: 23 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 20 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 6.0 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-E740-15KSC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-E740-15KSC Safety Stop compatible, 15kW | Applied Motor: 15 kW | Rated Capacity: 23.0 kVA | Rated Current: 30 A | Overload Current: 150% 60s, 200% 3s (inverse-time) | Output Voltage: 3-Phase 380-480V | Regenerative Torque: 20% | Input: 3-phase 380-480V 50\/60Hz | Input Voltage Range: 325-528V | Frequency Tolerance: ±5% | Power Supply Capacity: 28 kVA | Control Method: V\/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation | Max Frequency: 400 Hz | PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) | Brake Transistor: Built-in (0.4K and above) | Cooling: Forced air | Protection Structure: IP20 (enclosed) | Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) | Safety Function: EN ISO 13849-1 Cat.3 PLd \/ EN62061 SIL2 \/ IEC61508 SIL2 | Standards: UL, cUL, CE | Mass: 6.0 kg | Spec Type: Safety Stop compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":67396606296354,"sku":"MEL-FRE700-E740-SC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/0610-3_aa57bfe7-e5c8-4dea-bf54-85d01152c18a.png?v=1790662268"}],"url":"https:\/\/prosourcemro.com\/collections\/inverters-drives.oembed?page=2","provider":"ProSource MRO","version":"1.0","type":"link"}