Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - B-N100FN Class 2 Heat Resistant Main Circuit NC Magnetic Contactor (AC Operated, 84A Carrying, 2a2b Aux)
Family ID: MEL-FN-N100B
Mitsubishi Electric MS-T/N series B-N100FN class 2 heat-resistant magnetic contactor with normally closed b-contact main circuit, for emergency power distribution boards and panelboards where source changeover or dynamic braking duty is required. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 84A, heat-resistant rated current 84A at 220V under AC-1 class, 30A at DC110V, 3A at DC220V under DC2 and DC4 class in two-pole series connection. Main contact configuration 1a2b, 2a2b twin auxiliary contacts. AC operated coil, durability and outline dimensions the same as the standard product. Type approval number 2MC-02160. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.
7 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| B-N100FN AC24V | B-N100FN class 2 heat-resistant NC main contact contactor, AC24V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC24V · Coil Rating: 24V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| B-N100FN AC48V | B-N100FN class 2 heat-resistant NC main contact contactor, AC48V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC48V · Coil Rating: 48-50V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| B-N100FN AC100V | B-N100FN class 2 heat-resistant NC main contact contactor, AC100V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC100V · Coil Rating: 100-127V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| B-N100FN AC200V | B-N100FN class 2 heat-resistant NC main contact contactor, AC200V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC200V · Coil Rating: 200-240V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| B-N100FN AC300V | B-N100FN class 2 heat-resistant NC main contact contactor, AC300V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC300V · Coil Rating: 260-350V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| B-N100FN AC400V | B-N100FN class 2 heat-resistant NC main contact contactor, AC400V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC400V · Coil Rating: 380-440V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| B-N100FN AC500V | B-N100FN class 2 heat-resistant NC main contact contactor, AC500V coil, 1a2b main contacts | Mitsubishi Electric | Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC500V · Coil Rating: 460-550V · Heat Resistant Carrying Current: 84A · Heat Resistant Rated Current AC-1 Class: 84A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 30A at DC110V, 3A at DC220V · Heat Resistant Rated Current DC1 Class: 40A at DC110V, 20A at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02160 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature |