[Mitsubishi Electric] - B-N20FN Class 2 Heat Resistant Main Circuit NC Magnetic Contactor (AC Operated, 17.5A Carrying, 2a Aux)
Magnetic Contactors MITSUBISHI ELECTRIC

[Mitsubishi Electric] - B-N20FN Class 2 Heat Resistant Main Circuit NC Magnetic Contactor (AC Operated, 17.5A Carrying, 2a Aux)

Family ID: MEL-FN-N20B

Mitsubishi Electric MS-T/N series B-N20FN class 2 heat-resistant magnetic contactor with normally closed b-contact main circuit, for emergency power distribution boards and panelboards where source changeover or dynamic braking duty is required. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 17.5A, heat-resistant rated current 17.5A at 220V under AC-1 class, 8A (15A) at DC110V, 1A (5A) at DC220V under DC2 and DC4 class in two-pole series connection. Main contact configuration 1a2b standard and 3b optional, 2a twin auxiliary contacts. AC operated coil, durability and outline dimensions the same as the standard product. Type approval number 2MC-96134. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.

28 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
B-N20FN AC12V B-N20FN class 2 heat-resistant NC main contact contactor, AC12V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC12V · Coil Rating: 12V · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC12V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC12V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC12V · Coil Rating: 12V · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC24V B-N20FN class 2 heat-resistant NC main contact contactor, AC24V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC24V · Coil Rating: 24V · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC24V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC24V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC24V · Coil Rating: 24V · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC48V B-N20FN class 2 heat-resistant NC main contact contactor, AC48V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC48V · Coil Rating: 48-50V · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC48V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC48V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC48V · Coil Rating: 48-50V · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC100V B-N20FN class 2 heat-resistant NC main contact contactor, AC100V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC100V · Coil Rating: 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC100V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC100V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC100V · Coil Rating: 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC120V B-N20FN class 2 heat-resistant NC main contact contactor, AC120V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC120V · Coil Rating: 110-120V 50Hz, 115-120V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC120V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC120V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC120V · Coil Rating: 110-120V 50Hz, 115-120V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC127V B-N20FN class 2 heat-resistant NC main contact contactor, AC127V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC127V · Coil Rating: 125-127V 50Hz, 127V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC127V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC127V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC127V · Coil Rating: 125-127V 50Hz, 127V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC200V B-N20FN class 2 heat-resistant NC main contact contactor, AC200V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC200V · Coil Rating: 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC200V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC200V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC200V · Coil Rating: 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC220V B-N20FN class 2 heat-resistant NC main contact contactor, AC220V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC220V · Coil Rating: 208-220V 50Hz, 220V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC220V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC220V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC220V · Coil Rating: 208-220V 50Hz, 220V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC230V B-N20FN class 2 heat-resistant NC main contact contactor, AC230V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC230V · Coil Rating: 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC230V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC230V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC230V · Coil Rating: 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC260V B-N20FN class 2 heat-resistant NC main contact contactor, AC260V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC260V · Coil Rating: 240-260V 50Hz, 260-280V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC260V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC260V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC260V · Coil Rating: 240-260V 50Hz, 260-280V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC380V B-N20FN class 2 heat-resistant NC main contact contactor, AC380V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC380V · Coil Rating: 346-380V 50Hz, 380V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC380V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC380V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC380V · Coil Rating: 346-380V 50Hz, 380V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC400V B-N20FN class 2 heat-resistant NC main contact contactor, AC400V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC400V · Coil Rating: 380-415V 50Hz, 400-440V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC400V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC400V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC400V · Coil Rating: 380-415V 50Hz, 400-440V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC440V B-N20FN class 2 heat-resistant NC main contact contactor, AC440V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC440V · Coil Rating: 415-440V 50Hz, 460-480V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC440V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC440V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC440V · Coil Rating: 415-440V 50Hz, 460-480V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC500V B-N20FN class 2 heat-resistant NC main contact contactor, AC500V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a · Coil Designation: AC500V · Coil Rating: 500V 50Hz, 500-550V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N20FN AC500V 3B B-N20FN class 2 heat-resistant NC main contact contactor, AC500V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N20 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a · Coil Designation: AC500V · Coil Rating: 500V 50Hz, 500-550V 60Hz · Heat Resistant Carrying Current: 17.5A · Heat Resistant Rated Current AC-1 Class: 17.5A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 8A (15A) at DC110V, 1A (5A) at DC220V · Heat Resistant Rated Current DC1 Class: 15A (17.5A) at DC110V, 5A (10A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-96134 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature