[Mitsubishi Electric] - B-N65FN Class 2 Heat Resistant Main Circuit NC Magnetic Contactor (AC Operated, 56A Carrying, 2a2b Aux)
Magnetic Contactors MITSUBISHI ELECTRIC

[Mitsubishi Electric] - B-N65FN Class 2 Heat Resistant Main Circuit NC Magnetic Contactor (AC Operated, 56A Carrying, 2a2b Aux)

Family ID: MEL-FN-N65B

Mitsubishi Electric MS-T/N series B-N65FN class 2 heat-resistant magnetic contactor with normally closed b-contact main circuit, for emergency power distribution boards and panelboards where source changeover or dynamic braking duty is required. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 56A, heat-resistant rated current 56A at 220V under AC-1 class, 20A (50A) at DC110V, 3A (20A) at DC220V under DC2 and DC4 class in two-pole series connection. Main contact configuration 1a2b standard and 3b optional, 2a2b twin auxiliary contacts. AC operated coil, durability and outline dimensions the same as the standard product. Type approval number 2MC-02159. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.

14 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
B-N65FN AC24V B-N65FN class 2 heat-resistant NC main contact contactor, AC24V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC24V · Coil Rating: 24V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC24V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC24V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC24V · Coil Rating: 24V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC48V B-N65FN class 2 heat-resistant NC main contact contactor, AC48V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC48V · Coil Rating: 48-50V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC48V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC48V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC48V · Coil Rating: 48-50V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC100V B-N65FN class 2 heat-resistant NC main contact contactor, AC100V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC100V · Coil Rating: 100-127V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC100V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC100V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC100V · Coil Rating: 100-127V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC200V B-N65FN class 2 heat-resistant NC main contact contactor, AC200V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC200V · Coil Rating: 200-240V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC200V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC200V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC200V · Coil Rating: 200-240V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC300V B-N65FN class 2 heat-resistant NC main contact contactor, AC300V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC300V · Coil Rating: 260-350V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC300V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC300V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC300V · Coil Rating: 260-350V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC400V B-N65FN class 2 heat-resistant NC main contact contactor, AC400V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC400V · Coil Rating: 380-440V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC400V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC400V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC400V · Coil Rating: 380-440V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC500V B-N65FN class 2 heat-resistant NC main contact contactor, AC500V coil, 1a2b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 1a2b · Aux Contact: 2a2b · Coil Designation: AC500V · Coil Rating: 460-550V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
B-N65FN AC500V 3B B-N65FN class 2 heat-resistant NC main contact contactor, AC500V coil, 3b main contacts Mitsubishi Electric Type: Class 2 heat-resistant main circuit NC magnetic contactor · Frame: B-N65 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3b · Aux Contact: 2a2b · Coil Designation: AC500V · Coil Rating: 460-550V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-1 Class: 56A at 220V · Heat Resistant Rated Current DC2 and DC4 Class: 20A (50A) at DC110V, 3A (20A) at DC220V · Heat Resistant Rated Current DC1 Class: 30A (56A) at DC110V, 10A (30A) at DC220V · Durability: Same as the standard product · Type Approval Number: 2MC-02159 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature