Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - CD-202BB Heavy Duty Magnetic Contactor (2-pole, 250A Ith, 100kW at 380-440V)
Family ID: MEL-CD-202BB
Mitsubishi Electric MS-T/N series CD-202BB heavy duty magnetic contactor of European construction, suited to control of cranes, rolling mills and similar heavy industrial machinery. 2-pole main circuit, rated insulation voltage 660V at 50/60Hz, rated operational current 250A at 200-220V, 200A at 380-440V, 140A at 500-550V under AC-3 class and 250A at 200-220V, 200A at 380-440V, 200A at 500-550V under AC-2 class, rated capacity 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V under AC-3 class, rated carrying current 250A. Mounting dimensions are modularised in integer multiples of 50mm for easy combination into prefabricated panels, and the LI type auxiliary contact is common across the whole range and can be changed between a contact and b contact on a single unit. Auxiliary contacts 4 poles maximum, 2a2b standard. Switching frequency 1200 operations/h. Operating circuit accepts DC100V, DC110V, DC200V and DC220V, and the RF variant adds a built-in rectifier for AC100V, AC110V, AC200V and AC220V sources, with a tolerance of 85 to 110 percent of rated operating voltage. Reversing type is available as CD-2X202BB. Compliant with JEM1038. Special auxiliary contact configurations can be designated at the time of order.
16 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| CD-202BB DC100V | CD-202BB heavy duty contactor, DC100V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.66A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB DC100V | CD-2X202BB heavy duty contactor, DC100V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.66A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB DC110V | CD-202BB heavy duty contactor, DC110V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.60A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB DC110V | CD-2X202BB heavy duty contactor, DC110V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.60A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB DC200V | CD-202BB heavy duty contactor, DC200V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.33A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB DC200V | CD-2X202BB heavy duty contactor, DC200V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.33A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB DC220V | CD-202BB heavy duty contactor, DC220V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.30A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB DC220V | CD-2X202BB heavy duty contactor, DC220V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.30A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB-RF AC100V | CD-202BB-RF heavy duty contactor, AC100V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.66A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB-RF AC100V | CD-2X202BB-RF heavy duty contactor, AC100V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.66A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB-RF AC110V | CD-202BB-RF heavy duty contactor, AC110V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.60A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB-RF AC110V | CD-2X202BB-RF heavy duty contactor, AC110V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.60A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB-RF AC200V | CD-202BB-RF heavy duty contactor, AC200V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.33A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB-RF AC200V | CD-2X202BB-RF heavy duty contactor, AC200V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.33A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-202BB-RF AC220V | CD-202BB-RF heavy duty contactor, AC220V operating circuit, non-reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.30A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 | ||
| CD-2X202BB-RF AC220V | CD-2X202BB-RF heavy duty contactor, AC220V operating circuit, reversing | Mitsubishi Electric | Type: Heavy duty magnetic contactor, European style · Frame: CD-202BB · Poles: 2-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.30A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 250A at 200-220V, 200A at 380-440V, 140A at 500-550V · Rated Operational Current AC-2 Class: 250A at 200-220V, 200A at 380-440V, 200A at 500-550V · Rated Operational Current AC-1 Class: 250A at 550V · Rated Capacity AC-3 Class: 60kW at 200-220V, 100kW at 380-440V, 90kW at 500-550V · Rated Capacity AC-2 Class: 60kW at 200-220V, 100kW at 380-440V, 100kW at 500-550V · Rated Carrying Current Ith: 250A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038 |