[Mitsubishi Electric] - CD-405 Heavy Duty Magnetic Contactor (3-pole, 400A Ith, 150kW at 380-440V)
Magnetic Contactors MITSUBISHI ELECTRIC

[Mitsubishi Electric] - CD-405 Heavy Duty Magnetic Contactor (3-pole, 400A Ith, 150kW at 380-440V)

Family ID: MEL-CD-405

Mitsubishi Electric MS-T/N series CD-405 heavy duty magnetic contactor of European construction, suited to control of cranes, rolling mills and similar heavy industrial machinery. 3-pole main circuit, rated insulation voltage 660V at 50/60Hz, rated operational current 400A at 200-220V, 320A at 380-440V, 280A at 500-550V under AC-3 class and 400A at 200-220V, 400A at 380-440V, 400A at 500-550V under AC-2 class, rated capacity 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V under AC-3 class, rated carrying current 400A. Mounting dimensions are modularised in integer multiples of 50mm for easy combination into prefabricated panels, and the LI type auxiliary contact is common across the whole range and can be changed between a contact and b contact on a single unit. Auxiliary contacts 4 poles maximum, 2a2b standard. Switching frequency 1200 operations/h. Operating circuit accepts DC100V, DC110V, DC200V and DC220V, and the RF variant adds a built-in rectifier for AC100V, AC110V, AC200V and AC220V sources, with a tolerance of 85 to 110 percent of rated operating voltage. Reversing type is available as CD-2X405. Compliant with JEM1038. Special auxiliary contact configurations can be designated at the time of order.

16 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
CD-405 DC100V CD-405 heavy duty contactor, DC100V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405 DC100V CD-2X405 heavy duty contactor, DC100V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405 DC110V CD-405 heavy duty contactor, DC110V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405 DC110V CD-2X405 heavy duty contactor, DC110V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405 DC200V CD-405 heavy duty contactor, DC200V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405 DC200V CD-2X405 heavy duty contactor, DC200V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405 DC220V CD-405 heavy duty contactor, DC220V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405 DC220V CD-2X405 heavy duty contactor, DC220V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: DC source with DC operation · Operating Circuit Voltage: DC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405-RF AC100V CD-405-RF heavy duty contactor, AC100V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405-RF AC100V CD-2X405-RF heavy duty contactor, AC100V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC100V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.2A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405-RF AC110V CD-405-RF heavy duty contactor, AC110V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405-RF AC110V CD-2X405-RF heavy duty contactor, AC110V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC110V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 1.1A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405-RF AC200V CD-405-RF heavy duty contactor, AC200V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405-RF AC200V CD-2X405-RF heavy duty contactor, AC200V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC200V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.6A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-405-RF AC220V CD-405-RF heavy duty contactor, AC220V operating circuit, non-reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Non-reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038
CD-2X405-RF AC220V CD-2X405-RF heavy duty contactor, AC220V operating circuit, reversing Mitsubishi Electric Type: Heavy duty magnetic contactor, European style · Frame: CD-405 · Poles: 3-pole · Configuration: Reversing · Rectifier: AC source with DC operation, built-in rectifier · Operating Circuit Voltage: AC220V · Operating Voltage Tolerance: 85 to 110 percent of rated operating voltage · Operating Circuit Current: 0.55A at 20 degrees C cold with rated voltage applied · Rated Insulation Voltage: 660V · Rated Frequency: 50/60Hz · Rated Operational Current AC-3 Class: 400A at 200-220V, 320A at 380-440V, 280A at 500-550V · Rated Operational Current AC-2 Class: 400A at 200-220V, 400A at 380-440V, 400A at 500-550V · Rated Operational Current AC-1 Class: 400A at 550V · Rated Capacity AC-3 Class: 100kW at 200-220V, 150kW at 380-440V, 150kW at 500-550V · Rated Capacity AC-2 Class: 100kW at 200-220V, 200kW at 380-440V, 200kW at 500-550V · Rated Carrying Current Ith: 400A · Switching Frequency: 1200 operations/h · Aux Contact: 4 poles maximum, 2a2b standard · Aux Contact Rating: LI type auxiliary contact common to all models, a single unit can be changed between a contact and b contact, rated insulation voltage AC660V, rated operational current AC-15 class 10A at 220V and 6A at 440V and 5A at 550V, DC-13 class 5A at 55V and 3A at 110V and 1A at 220V, contact thermal current 15A · Standards: JEM1038