Thermal Overload Relays
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - ET-N60 Electronic Motor Protection Relay (60A frame, 0.25 to 60A Setting Range)
Family ID: MEL-ETN-N60
Mitsubishi Electric MS-T/N series ET-N60 electronic motor protection relay that detects overload including locked rotor, open phase including current imbalance, and reverse phase conditions during AC motor starting and running. 60A frame covering current settings 0.25 to 60A across 5 setting designations, with a setting range of three to four times the minimum scale. A protection mode switch selects overload only, overload plus open phase, or overload plus open phase plus reverse phase, and the overload operating time is selectable between 3, 5, 7, 15 and 30 seconds at 600 percent of the setting current. Independent 1a1b output contacts can be used on different voltage circuits, indicators show power, overload, open phase and reverse phase status as well as load run and stop, and a self diagnosis function trips the relay on an internal fault. Operating voltage AC100V or AC200V with 85 to 110 percent tolerance, manual reset, main circuit terminal connection with no need to wind the main circuit conductor. The 78mm body width helps reduce control panel dimensions and the unit mounts on a 35mm rail to IEC, DIN and JIS requirements.
10 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| ET-N60 1A AC100V | ET-N60 electronic motor protection relay, 1A setting, AC100V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 1A · Current Setting Range: 0.25 to 1A · Applicable Motor Capacity: 0.03 to 0.2kW at 200-220V, 0.05 to 0.4kW at 400-440V · Operating Voltage: AC100V · Operating Circuit: AC100-120V 50/60Hz, 7VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 1A AC200V | ET-N60 electronic motor protection relay, 1A setting, AC200V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 1A · Current Setting Range: 0.25 to 1A · Applicable Motor Capacity: 0.03 to 0.2kW at 200-220V, 0.05 to 0.4kW at 400-440V · Operating Voltage: AC200V · Operating Circuit: AC200-240V 50/60Hz, 14VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 4A AC100V | ET-N60 electronic motor protection relay, 4A setting, AC100V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 4A · Current Setting Range: 1 to 4A · Applicable Motor Capacity: 0.2 to 0.75kW at 200-220V, 0.4 to 1.5kW at 400-440V · Operating Voltage: AC100V · Operating Circuit: AC100-120V 50/60Hz, 7VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 4A AC200V | ET-N60 electronic motor protection relay, 4A setting, AC200V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 4A · Current Setting Range: 1 to 4A · Applicable Motor Capacity: 0.2 to 0.75kW at 200-220V, 0.4 to 1.5kW at 400-440V · Operating Voltage: AC200V · Operating Circuit: AC200-240V 50/60Hz, 14VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 8A AC100V | ET-N60 electronic motor protection relay, 8A setting, AC100V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 8A · Current Setting Range: 2 to 8A · Applicable Motor Capacity: 0.4 to 1.5kW at 200-220V, 0.75 to 2.2kW at 400-440V · Operating Voltage: AC100V · Operating Circuit: AC100-120V 50/60Hz, 7VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 8A AC200V | ET-N60 electronic motor protection relay, 8A setting, AC200V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 8A · Current Setting Range: 2 to 8A · Applicable Motor Capacity: 0.4 to 1.5kW at 200-220V, 0.75 to 2.2kW at 400-440V · Operating Voltage: AC200V · Operating Circuit: AC200-240V 50/60Hz, 14VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 20A AC100V | ET-N60 electronic motor protection relay, 20A setting, AC100V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 20A · Current Setting Range: 5 to 20A · Applicable Motor Capacity: 1.5 to 4kW at 200-220V, 2.2 to 7.5kW at 400-440V · Operating Voltage: AC100V · Operating Circuit: AC100-120V 50/60Hz, 7VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 20A AC200V | ET-N60 electronic motor protection relay, 20A setting, AC200V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 20A · Current Setting Range: 5 to 20A · Applicable Motor Capacity: 1.5 to 4kW at 200-220V, 2.2 to 7.5kW at 400-440V · Operating Voltage: AC200V · Operating Circuit: AC200-240V 50/60Hz, 14VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 60A AC100V | ET-N60 electronic motor protection relay, 60A setting, AC100V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 60A · Current Setting Range: 15 to 60A · Applicable Motor Capacity: 3.7 to 11kW at 200-220V, 7.5 to 22kW at 400-440V · Operating Voltage: AC100V · Operating Circuit: AC100-120V 50/60Hz, 7VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault | ||
| ET-N60 60A AC200V | ET-N60 electronic motor protection relay, 60A setting, AC200V control | Mitsubishi Electric | Type: Electronic motor protection relay · Frame: N60 60A frame · Current Setting Designation: 60A · Current Setting Range: 15 to 60A · Applicable Motor Capacity: 3.7 to 11kW at 200-220V, 7.5 to 22kW at 400-440V · Operating Voltage: AC200V · Operating Circuit: AC200-240V 50/60Hz, 14VA input · Rated Insulation Voltage: 660V 50/60Hz main circuit · Operating Voltage Tolerance: 85 to 110 percent of rated voltage · Output Contact: 1a1b with independent a and b contacts usable on different voltage circuits · Output Contact Rating: AC240V 1A, AC120V 2A under AC-15 class · Reset: Manual reset · Protection Mode: Overload, overload plus open phase, or overload plus open phase plus reverse phase, selected by the protection mode switch · Overload Operating Current: 115 plus or minus 5 percent of the setting · Overload Operating Time: 3, 5, 7, 15 or 30 seconds selectable at 600 percent of the setting current · Indication: Power, overload, open phase and reverse phase indicators plus load run and stop status · Self Diagnosis: Trips on detection of an internal fault |