Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - S-T100FN Class 2 Heat Resistant Magnetic Contactor (AC Operated, 105A Carrying, 100A AC-3 at 220V)
Family ID: MEL-FN-T100
Mitsubishi Electric MS-T/N series S-T100FN class 2 heat-resistant magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire so that power to fire fighting equipment continues, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 105A, heat-resistant rated current 100A at 220V, 93A at 440V, 75A at 550V under AC-3 class and 105A at 220V, 105A at 440V under AC-1 class, 3a main contacts. AC operated coil, durability and outline dimensions the same as the standard product. Reversing type S-2XT100FN is available. Type approval number 2MC-16175. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.
14 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| S-T100FN AC24V | S-T100FN class 2 heat-resistant contactor, AC24V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC24V · Coil Rating: 24V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC24V | S-2XT100FN class 2 heat-resistant contactor, AC24V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC24V · Coil Rating: 24V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-T100FN AC48V | S-T100FN class 2 heat-resistant contactor, AC48V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC48V · Coil Rating: 48-50V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC48V | S-2XT100FN class 2 heat-resistant contactor, AC48V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC48V · Coil Rating: 48-50V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-T100FN AC100V | S-T100FN class 2 heat-resistant contactor, AC100V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC100V · Coil Rating: 100-127V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC100V | S-2XT100FN class 2 heat-resistant contactor, AC100V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC100V · Coil Rating: 100-127V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-T100FN AC200V | S-T100FN class 2 heat-resistant contactor, AC200V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC200V · Coil Rating: 200-240V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC200V | S-2XT100FN class 2 heat-resistant contactor, AC200V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC200V · Coil Rating: 200-240V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-T100FN AC300V | S-T100FN class 2 heat-resistant contactor, AC300V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC300V · Coil Rating: 260-350V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC300V | S-2XT100FN class 2 heat-resistant contactor, AC300V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC300V · Coil Rating: 260-350V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-T100FN AC400V | S-T100FN class 2 heat-resistant contactor, AC400V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC400V · Coil Rating: 380-440V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC400V | S-2XT100FN class 2 heat-resistant contactor, AC400V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC400V · Coil Rating: 380-440V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-T100FN AC500V | S-T100FN class 2 heat-resistant contactor, AC500V coil, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Non-reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b · Coil Designation: AC500V · Coil Rating: 460-550V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| S-2XT100FN AC500V | S-2XT100FN class 2 heat-resistant contactor, AC500V coil, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant magnetic contactor for emergency power switchboards · Frame: T100 · Configuration: Reversing · Operation: AC operated · Main Contact: 3a · Aux Contact: 2a2b x2 · Coil Designation: AC500V · Coil Rating: 460-550V 50/60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16175 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature |