Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - SHD-V160 Vacuum Magnetic Contactor (DC operated, 200A Ith, 180A 90kW at AC440V)
Family ID: MEL-SHV-D-V160
Mitsubishi Electric MS-T/N series SHD-V160 large capacity vacuum magnetic contactor combining a vacuum switch with an AC operated DC excited electromagnet for high performance, long life and maintenance free operation. Rated insulation voltage 1500V three phase, rated operational current and capacity 180A 45kW at AC220V, 180A 90kW at AC440V, 180A 110kW at AC550V, 160A 220kW at AC1000V, 160A 315kW at AC1500V, three phase capacitor rating 150A 50kVA at AC220V, 150A 100kVA at AC440V, 150A 125kVA at AC550V, open thermal current 200A. No arc clearance is required so the panel can be made smaller, there is no coil humming or current interruption noise, and there is no arc blowout which keeps the unit safe in harsh ambient conditions. Switching frequency 1200 operations per hour. Electrical 500,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 2,500,000 operations. Standard auxiliary contacts 2a2b, with a 4a4b configuration available on request. Compliant with JIS C8201-4-1, JEM 1038, IEC 60947-4-1. A surge absorber is not required for motor loads of 7.5kW and above but should be fitted for loads of 5.5kW and below. SH-V160 to V600 carry UL component recognition and CSA certification.
2 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SHD-V160 DC100V | SHD-V160 vacuum contactor, DC100V coil | Mitsubishi Electric | Type: Vacuum magnetic contactor · Frame: V160 · Operation: DC operated · Coil Designation: DC100V · Coil Rating: DC100-110V · Rated Insulation Voltage: 1500V three phase 50/60Hz · Rated Current and Capacity AC-3 Class: 180A 45kW at AC220V, 180A 90kW at AC440V, 180A 110kW at AC550V, 160A 220kW at AC1000V, 160A 315kW at AC1500V · Three Phase Capacitor Rating: 150A 50kVA at AC220V, 150A 100kVA at AC440V, 150A 125kVA at AC550V · Open Thermal Current Ith: 200A · Switching Frequency: 1200 operations/h · Durability: Electrical 500,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 2,500,000 operations · Operating Voltage: Pick up at 85 percent or less of rated voltage at 40 degrees C ambient, drop out at 10 percent or more at 20 degrees C · Characteristics: Main contact ON 40ms, main contact OFF 130ms, coil input inrush 480VA and sealed 40VA · Aux Contact: 2a2b standard, rated operational current AC-15 class 5A at AC220V and 3A at AC440V, DC-13 class 0.6A at DC110V and 0.2A at DC220V, conforming to JIS C4531 (1994) · Standards: JIS C8201-4-1, JEM 1038, IEC 60947-4-1 | ||
| SHD-V160 DC200V | SHD-V160 vacuum contactor, DC200V coil | Mitsubishi Electric | Type: Vacuum magnetic contactor · Frame: V160 · Operation: DC operated · Coil Designation: DC200V · Coil Rating: DC200-220V · Rated Insulation Voltage: 1500V three phase 50/60Hz · Rated Current and Capacity AC-3 Class: 180A 45kW at AC220V, 180A 90kW at AC440V, 180A 110kW at AC550V, 160A 220kW at AC1000V, 160A 315kW at AC1500V · Three Phase Capacitor Rating: 150A 50kVA at AC220V, 150A 100kVA at AC440V, 150A 125kVA at AC550V · Open Thermal Current Ith: 200A · Switching Frequency: 1200 operations/h · Durability: Electrical 500,000 operations on three phase motor AC-3 class, 100,000 operations on three phase capacitor, mechanical 2,500,000 operations · Operating Voltage: Pick up at 85 percent or less of rated voltage at 40 degrees C ambient, drop out at 10 percent or more at 20 degrees C · Characteristics: Main contact ON 40ms, main contact OFF 130ms, coil input inrush 480VA and sealed 40VA · Aux Contact: 2a2b standard, rated operational current AC-15 class 5A at AC220V and 3A at AC440V, DC-13 class 0.6A at DC110V and 0.2A at DC220V, conforming to JIS C4531 (1994) · Standards: JIS C8201-4-1, JEM 1038, IEC 60947-4-1 |