[Mitsubishi Electric] - SL-N80FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 94.5A Carrying, 80A AC-3 at 220V)
Magnetic Contactors MITSUBISHI ELECTRIC

[Mitsubishi Electric] - SL-N80FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 94.5A Carrying, 80A AC-3 at 220V)

Family ID: MEL-FK-SL-N80

Mitsubishi Electric MS-T/N series SL-N80FK class 1 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one third fire temperature curve. Heat-resistant carrying current 94.5A, heat-resistant rated current 80A at AC220V, 80A at AC440V, 75A at AC550V under AC-3 class, 3a main contacts with 1a2b auxiliary contacts. Separate closing coil MC and tripping coil MT are specified independently; the closing coil is AC operated in AC24V, AC100V, AC200V and AC230V designations and the tripping coil may be any of the AC24V, AC100V, AC200V, AC230V, DC100V and DC200V designations. Mechanical and electrical durability 250,000 operations. Reversing type SL-2XN80FK is available, and the contactor can be switched from its own auxiliary contacts. Outline dimensions are the same as the standard product. Type approval number 1MC-99041. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item.

48 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
SL-N80FK MC-AC24V MT-AC24V SL-N80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC24V MT-AC24V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC24V MT-AC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC24V MT-AC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC24V MT-AC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC24V MT-AC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC24V MT-AC230V SL-N80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC24V MT-AC230V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC24V MT-DC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC24V MT-DC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC24V MT-DC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC24V MT-DC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC100V MT-AC24V SL-N80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC100V MT-AC24V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC100V MT-AC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC100V MT-AC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC100V MT-AC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC100V MT-AC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC100V MT-AC230V SL-N80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC100V MT-AC230V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC100V MT-DC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC100V MT-DC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC100V MT-DC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC100V MT-DC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC200V MT-AC24V SL-N80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC200V MT-AC24V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC200V MT-AC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC200V MT-AC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC200V MT-AC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC200V MT-AC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC200V MT-AC230V SL-N80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC200V MT-AC230V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC200V MT-DC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC200V MT-DC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC200V MT-DC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC200V MT-DC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC230V MT-AC24V SL-N80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC230V MT-AC24V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC230V MT-AC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC230V MT-AC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC230V MT-AC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC230V MT-AC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC230V MT-AC230V SL-N80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC230V MT-AC230V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC230V MT-DC100V SL-N80FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC230V MT-DC100V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N80FK MC-AC230V MT-DC200V SL-N80FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN80FK MC-AC230V MT-DC200V SL-2XN80FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N80 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 94.5A · Heat Resistant Rated Current AC-3 Class: 80A at AC220V, 80A at AC440V, 75A at AC550V · Heat Resistant Rated Current AC-1 Class: 94.5A at AC220V, 94.5A at AC440V · DC Rated Current at DC48V: 40A 2-pole series, 60A 3-pole series (DC2 and DC4 class), 65A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC110V: 20A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · DC Rated Current at DC220V: 5A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 60A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 3900VA closing and 1500VA tripping, DC operated 460VA closing and 390VA tripping · Operating Voltage: AC operated 110V closing and 100V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 11ms closing and 8ms tripping, DC operated 17ms closing and 10ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99041 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981