Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - SL-T100FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 105A Carrying, 100A AC-3 at 220V)
Family ID: MEL-FN-SL-T100
Mitsubishi Electric MS-T/N series SL-T100FN class 2 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 105A, heat-resistant rated current 100A at 220V, 93A at 440V, 75A at 550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts. Closing coil MC and tripping coil MT are specified independently; the closing coil is AC operated and the tripping coil may be any AC or DC designation available on the frame. Reversing type SL-2XT100FN is available. Durability and outline dimensions are the same as the standard product. Type approval number 2MC-16178. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature. AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V.
110 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SL-T100FN MC-AC100V MT-AC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-AC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-AC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-AC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-AC300V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-AC300V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-AC400V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-AC400V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-AC500V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-AC500V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-DC12V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-DC12V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-DC24V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-DC24V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-DC48V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-DC48V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-DC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-DC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-DC125V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-DC125V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC100V MT-DC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC100V MT-DC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-AC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-AC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-AC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-AC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-AC300V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-AC300V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-AC400V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-AC400V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-AC500V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-AC500V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-DC12V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-DC12V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-DC24V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-DC24V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-DC48V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-DC48V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-DC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-DC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-DC125V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-DC125V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC200V MT-DC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC200V MT-DC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-AC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-AC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-AC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-AC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-AC300V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-AC300V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-AC400V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-AC400V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-AC500V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-AC500V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-DC12V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-DC12V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-DC24V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-DC24V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-DC48V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-DC48V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-DC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-DC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-DC125V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-DC125V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC300V MT-DC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC300V MT-DC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-AC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-AC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-AC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-AC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-AC300V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-AC300V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-AC400V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-AC400V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-AC500V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-AC500V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-DC12V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-DC12V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-DC24V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-DC24V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-DC48V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-DC48V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-DC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-DC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-DC125V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-DC125V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC400V MT-DC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC400V MT-DC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-AC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-AC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-AC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-AC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-AC300V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-AC300V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-AC400V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-AC400V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-AC500V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-AC500V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-DC12V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-DC12V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-DC24V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-DC24V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-DC48V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-DC48V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-DC100V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-DC100V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-DC125V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-DC125V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T100FN MC-AC500V MT-DC200V | SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT100FN MC-AC500V MT-DC200V | SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T100 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: AC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V · Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-16178 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature |