Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - SLD-N125FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (DC Operated Closing Coil, 105A Carrying, 105A AC-3 at 220V)
Family ID: MEL-FK-SLD-N125
Mitsubishi Electric MS-T/N series SLD-N125FK class 1 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one third fire temperature curve. Heat-resistant carrying current 105A, heat-resistant rated current 105A at AC220V, 105A at AC440V, 90A at AC550V under AC-3 class, 3a main contacts with 1a2b auxiliary contacts. Separate closing coil MC and tripping coil MT are specified independently; the closing coil is DC operated in DC100V and DC200V designations and the tripping coil may be any of the AC24V, AC100V, AC200V, AC230V, DC100V and DC200V designations. Mechanical and electrical durability 250,000 operations. Reversing type SLD-2XN125FK is available, and the contactor can be switched from its own auxiliary contacts. Outline dimensions are the same as the standard product. Type approval number 1MC-99042. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item.
24 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SLD-N125FK MC-DC100V MT-AC24V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC100V MT-AC24V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC100V MT-AC100V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC100V MT-AC100V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC100V MT-AC200V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC100V MT-AC200V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC100V MT-AC230V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC230V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC100V MT-AC230V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC100V and MT AC230V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC100V MT-DC100V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC100V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC100V MT-DC100V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC100V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC100V MT-DC200V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC100V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC100V MT-DC200V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC100V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC200V MT-AC24V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC200V MT-AC24V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC200V MT-AC100V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC200V MT-AC100V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC200V MT-AC200V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC200V MT-AC200V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC200V MT-AC230V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC230V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC200V MT-AC230V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC200V and MT AC230V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC200V MT-DC100V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC200V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC200V MT-DC100V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC200V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-N125FK MC-DC200V MT-DC200V | SLD-N125FK class 1 heat-resistant latch contactor, MC DC200V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 1a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | ||
| SLD-2XN125FK MC-DC200V MT-DC200V | SLD-2XN125FK class 1 heat-resistant latch contactor, MC DC200V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N125 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 1a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 105A · Heat Resistant Rated Current AC-3 Class: 105A at AC220V, 105A at AC440V, 90A at AC550V · Heat Resistant Rated Current AC-1 Class: 105A at AC220V, 105A at AC440V · DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 100A 2-pole series, 120A 3-pole series (DC1 class) · DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 100A 3-pole series (DC1 class) · DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 80A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 4100VA closing and 1400VA tripping, DC operated 470VA closing and 300VA tripping · Operating Voltage: AC operated 122V closing and 66V tripping, DC operated 45V closing and 40V tripping · Operating Time: AC operated 12ms closing and 9ms tripping, DC operated 17ms closing and 9ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99042 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 |