[Mitsubishi Electric] - SLD-N50FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (DC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)
Magnetic Contactors MITSUBISHI ELECTRIC

[Mitsubishi Electric] - SLD-N50FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (DC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)

Family ID: MEL-FK-SLD-N50

Mitsubishi Electric MS-T/N series SLD-N50FK class 1 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one third fire temperature curve. Heat-resistant carrying current 56A, heat-resistant rated current 50A at AC220V, 48A at AC440V, 38A at AC550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts. Separate closing coil MC and tripping coil MT are specified independently; the closing coil is DC operated in DC100V and DC200V designations and the tripping coil may be any of the AC24V, AC100V, AC200V, AC230V, DC100V and DC200V designations. Mechanical and electrical durability 250,000 operations. Reversing type SLD-2XN50FK is available, and the contactor can be switched from its own auxiliary contacts. Outline dimensions are the same as the standard product. Type approval number 1MC-99040. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item.

24 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
SLD-N50FK MC-DC100V MT-AC24V SLD-N50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC24V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC100V MT-AC24V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC24V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC100V MT-AC100V SLD-N50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC100V MT-AC100V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC100V MT-AC200V SLD-N50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC100V MT-AC200V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC100V MT-AC230V SLD-N50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC230V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC100V MT-AC230V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC100V and MT AC230V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC100V MT-DC100V SLD-N50FK class 1 heat-resistant latch contactor, MC DC100V and MT DC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC100V MT-DC100V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC100V and MT DC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC100V MT-DC200V SLD-N50FK class 1 heat-resistant latch contactor, MC DC100V and MT DC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC100V MT-DC200V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC100V and MT DC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC200V MT-AC24V SLD-N50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC24V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC200V MT-AC24V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC24V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC200V MT-AC100V SLD-N50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC200V MT-AC100V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC200V MT-AC200V SLD-N50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC200V MT-AC200V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC200V MT-AC230V SLD-N50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC230V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC200V MT-AC230V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC200V and MT AC230V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC200V MT-DC100V SLD-N50FK class 1 heat-resistant latch contactor, MC DC200V and MT DC100V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC200V MT-DC100V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC200V and MT DC100V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-N50FK MC-DC200V MT-DC200V SLD-N50FK class 1 heat-resistant latch contactor, MC DC200V and MT DC200V, non-reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Non-reversing · Main Contact: 3a · Aux Contact: 2a2b · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SLD-2XN50FK MC-DC200V MT-DC200V SLD-2XN50FK class 1 heat-resistant latch contactor, MC DC200V and MT DC200V, reversing Mitsubishi Electric Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards · Frame: N50 · Configuration: Reversing · Main Contact: 3a · Aux Contact: 2a2b x2 · Mechanism: Mechanical latch · Operation: DC operated closing coil · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V · Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V · Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping · Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping · Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping · Durability: Mechanical and electrical 250,000 operations · Type Approval Number: 1MC-99040 · Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981