[Mitsubishi Electric] - SLD-T21FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (DC Operated Closing Coil, 22.4A Carrying, 20A AC-3 at 220V)
Family ID: MEL-FN-SLD-T21
Mitsubishi Electric MS-T/N series SLD-T21FN class 2 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 22.4A, heat-resistant rated current 20A at 220V, 20A at 440V, 17A at 550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts. Closing coil MC and tripping coil MT are specified independently; the closing coil is DC operated and the tripping coil may be any AC or DC designation available on the frame. Reversing type SLD-2XT21FN is available. Durability and outline dimensions are the same as the standard product. Type approval number 2MC-14171. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.
168 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SLD-T21FN MC-DC12V MT-AC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC300V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC300V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC400V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC400V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC500V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC500V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-AC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-AC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT AC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-DC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-DC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-DC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-DC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-DC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-DC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-DC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-DC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-DC125V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-DC125V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC12V MT-DC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC12V MT-DC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC12V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC300V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC300V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC400V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC400V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC500V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC500V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-AC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-AC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT AC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-DC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-DC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-DC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-DC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-DC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-DC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-DC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-DC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-DC125V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-DC125V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC24V MT-DC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC24V MT-DC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC24V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC300V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC300V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC400V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC400V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC500V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC500V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-AC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-AC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT AC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-DC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-DC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-DC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-DC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-DC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-DC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-DC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-DC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-DC125V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-DC125V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC48V MT-DC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC48V MT-DC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC48V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC300V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC300V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC400V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC400V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC500V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC500V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-AC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-AC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT AC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-DC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-DC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-DC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-DC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-DC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-DC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-DC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-DC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-DC125V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-DC125V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC100V MT-DC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC100V MT-DC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC100V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC300V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC300V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC400V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC400V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC500V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC500V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-AC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-AC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT AC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-DC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-DC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-DC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-DC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-DC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-DC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-DC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-DC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-DC125V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-DC125V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC125V MT-DC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC125V MT-DC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC125V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC300V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC300V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC400V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC400V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC500V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC500V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-AC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-AC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT AC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-DC12V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-DC12V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-DC24V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-DC24V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-DC48V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-DC48V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-DC100V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-DC100V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-DC125V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-DC125V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T21FN MC-DC200V MT-DC200V | SLD-T21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT21FN MC-DC200V MT-DC200V | SLD-2XT21FN class 2 heat-resistant latch contactor, MC DC200V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T21 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 22.4A · Heat Resistant Rated Current AC-3 Class: 20A at 220V, 20A at 440V, 17A at 550V · Heat Resistant Rated Current AC-1 Class: 22.4A at 220V, 22.4A at 440V · DC Rated Current at DC48V: 15A 2-pole series, 20A 3-pole series (DC2 and DC4 class), 20A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC110V: 8A 2-pole series, 15A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 20A 3-pole series (DC1 class) · DC Rated Current at DC220V: 2A 2-pole series, 8A 3-pole series (DC2 and DC4 class), 10A 2-pole series, 20A 3-pole series (DC1 class) · Durability: Same as the standard product · Type Approval Number: 2MC-14171 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature |