Magnetic Contactors
MITSUBISHI ELECTRIC
[Mitsubishi Electric] - SLD-T50FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (DC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)
Family ID: MEL-FN-SLD-T50
Mitsubishi Electric MS-T/N series SLD-T50FN class 2 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 56A, heat-resistant rated current 50A at 220V, 48A at 440V, 38A at 550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts. Closing coil MC and tripping coil MT are specified independently; the closing coil is DC operated and the tripping coil may be any AC or DC designation available on the frame. Reversing type SLD-2XT50FN is available. Durability and outline dimensions are the same as the standard product. Type approval number 2MC-16176. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature. AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V.
132 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SLD-T50FN MC-DC12V MT-AC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-AC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-AC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-AC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-AC300V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-AC300V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-AC400V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-AC400V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-AC500V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-AC500V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-DC12V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-DC12V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-DC24V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-DC24V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-DC48V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-DC48V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-DC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-DC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-DC125V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-DC125V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC12V MT-DC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC12V MT-DC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC12V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC12V rated DC12V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-AC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-AC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-AC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-AC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-AC300V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-AC300V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-AC400V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-AC400V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-AC500V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-AC500V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-DC12V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-DC12V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-DC24V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-DC24V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-DC48V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-DC48V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-DC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-DC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-DC125V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-DC125V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC24V MT-DC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC24V MT-DC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC24V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC24V rated DC24V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-AC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-AC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-AC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-AC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-AC300V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-AC300V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-AC400V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-AC400V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-AC500V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-AC500V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-DC12V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-DC12V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-DC24V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-DC24V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-DC48V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-DC48V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-DC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-DC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-DC125V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-DC125V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC48V MT-DC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC48V MT-DC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC48V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC48V rated DC48V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-AC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-AC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-AC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-AC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-AC300V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-AC300V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-AC400V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-AC400V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-AC500V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-AC500V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-DC12V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-DC12V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-DC24V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-DC24V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-DC48V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-DC48V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-DC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-DC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-DC125V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-DC125V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC100V MT-DC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC100V MT-DC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC100V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC100V rated DC100-110V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-AC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-AC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-AC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-AC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-AC300V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-AC300V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-AC400V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-AC400V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-AC500V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-AC500V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-DC12V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-DC12V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-DC24V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-DC24V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-DC48V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-DC48V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-DC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-DC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-DC125V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-DC125V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC125V MT-DC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC125V MT-DC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC125V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC125V rated DC120-125V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-AC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-AC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC100V rated 100-127V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-AC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-AC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC200V rated 200-240V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-AC300V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC300V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-AC300V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC300V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC300V rated 260-350V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-AC400V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC400V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-AC400V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC400V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC400V rated 380-440V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-AC500V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC500V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-AC500V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT AC500V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: AC500V rated 460-550V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-DC12V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC12V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-DC12V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC12V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC12V rated DC12V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-DC24V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC24V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-DC24V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC24V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC24V rated DC24V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-DC48V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC48V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-DC48V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC48V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC48V rated DC48V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-DC100V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC100V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-DC100V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC100V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC100V rated DC100-110V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-DC125V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC125V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-DC125V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC125V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC125V rated DC120-125V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-T50FN MC-DC200V MT-DC200V | SLD-T50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC200V, non-reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Non-reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SLD-2XT50FN MC-DC200V MT-DC200V | SLD-2XT50FN class 2 heat-resistant latch contactor, MC DC200V and MT DC200V, reversing | Mitsubishi Electric | Type: Class 2 heat-resistant mechanical latch magnetic contactor · Frame: T50 · Configuration: Reversing · Mechanism: Mechanical latch · Operation: DC operated closing coil · Main Contact: 3a · Aux Contact: 2a2b x2 · Closing Coil MC: DC200V rated DC200-220V · Tripping Coil MT: DC200V rated DC200-220V · Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V · Heat Resistant Carrying Current: 56A · Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V · Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V · DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) · DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) · Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping · Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping · Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping · Durability: Same as the standard product · Type Approval Number: 2MC-16176 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature |