Auxiliary Relays
MITSUBISHI ELECTRIC
[MITSUBISHI ELECTRIC] — SR-T5LC Overlap Contact Auxiliary Relay (T5 Frame, AC/DC Coil)
Family ID: MEL-SR-T5LC
Mitsubishi Electric SR-T5LC / SRD-T5LC auxiliary relay with overlapping contacts: the a-contact closes before the b-contact opens, for circuits requiring make-before-break transfer. Contact arrangements 4a1b, 3a2b. Open thermal current Ith 16A, rated insulation voltage 690V. b-contact rating: closing current 20A, breaking current 3A at AC24-550V. AC-operated (SR) and DC-operated (SRD) coils. Dimensions identical to the standard SR/SRD relay. Conforms to JIS C8201-5-1, IEC 60947-5-1, EN 60947-5-1, GB14048.5. IEC 35mm rail mounting.
30 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SR-T5LC AC24V 4A1B | Overlap contact relay SR-T5LC, AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC24V · Operation: AC | ||
| SR-T5LC AC24V 3A2B | Overlap contact relay SR-T5LC, AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC24V · Operation: AC | ||
| SR-T5LC AC48V 4A1B | Overlap contact relay SR-T5LC, AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC48V · Operation: AC | ||
| SR-T5LC AC48V 3A2B | Overlap contact relay SR-T5LC, AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC48V · Operation: AC | ||
| SR-T5LC AC100V 4A1B | Overlap contact relay SR-T5LC, AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC100V · Operation: AC | ||
| SR-T5LC AC100V 3A2B | Overlap contact relay SR-T5LC, AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC100V · Operation: AC | ||
| SR-T5LC AC200V 4A1B | Overlap contact relay SR-T5LC, AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC200V · Operation: AC | ||
| SR-T5LC AC200V 3A2B | Overlap contact relay SR-T5LC, AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC200V · Operation: AC | ||
| SR-T5LC AC300V 4A1B | Overlap contact relay SR-T5LC, AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC300V · Operation: AC | ||
| SR-T5LC AC300V 3A2B | Overlap contact relay SR-T5LC, AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC300V · Operation: AC | ||
| SR-T5LC AC400V 4A1B | Overlap contact relay SR-T5LC, AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC400V · Operation: AC | ||
| SR-T5LC AC400V 3A2B | Overlap contact relay SR-T5LC, AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC400V · Operation: AC | ||
| SR-T5LC AC500V 4A1B | Overlap contact relay SR-T5LC, AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: AC500V · Operation: AC | ||
| SR-T5LC AC500V 3A2B | Overlap contact relay SR-T5LC, AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: AC500V · Operation: AC | ||
| SRD-T5LC DC12V 4A1B | Overlap contact relay SRD-T5LC, DC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC12V · Operation: DC | ||
| SRD-T5LC DC12V 3A2B | Overlap contact relay SRD-T5LC, DC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC12V · Operation: DC | ||
| SRD-T5LC DC24V 4A1B | Overlap contact relay SRD-T5LC, DC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC24V · Operation: DC | ||
| SRD-T5LC DC24V 3A2B | Overlap contact relay SRD-T5LC, DC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC24V · Operation: DC | ||
| SRD-T5LC DC48V 4A1B | Overlap contact relay SRD-T5LC, DC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC48V · Operation: DC | ||
| SRD-T5LC DC48V 3A2B | Overlap contact relay SRD-T5LC, DC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC48V · Operation: DC | ||
| SRD-T5LC DC100V 4A1B | Overlap contact relay SRD-T5LC, DC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC100V · Operation: DC | ||
| SRD-T5LC DC100V 3A2B | Overlap contact relay SRD-T5LC, DC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC100V · Operation: DC | ||
| SRD-T5LC DC110V 4A1B | Overlap contact relay SRD-T5LC, DC110V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC110V · Operation: DC | ||
| SRD-T5LC DC110V 3A2B | Overlap contact relay SRD-T5LC, DC110V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC110V · Operation: DC | ||
| SRD-T5LC DC125V 4A1B | Overlap contact relay SRD-T5LC, DC125V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC125V · Operation: DC | ||
| SRD-T5LC DC125V 3A2B | Overlap contact relay SRD-T5LC, DC125V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC125V · Operation: DC | ||
| SRD-T5LC DC200V 4A1B | Overlap contact relay SRD-T5LC, DC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC200V · Operation: DC | ||
| SRD-T5LC DC200V 3A2B | Overlap contact relay SRD-T5LC, DC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC200V · Operation: DC | ||
| SRD-T5LC DC220V 4A1B | Overlap contact relay SRD-T5LC, DC220V, 4a1b | MITSUBISHI ELECTRIC | Contacts: 4a1b · Coil: DC220V · Operation: DC | ||
| SRD-T5LC DC220V 3A2B | Overlap contact relay SRD-T5LC, DC220V, 3a2b | MITSUBISHI ELECTRIC | Contacts: 3a2b · Coil: DC220V · Operation: DC |