Mitsubishi Electric MS-T/N series SR-T9FN class 2 heat-resistant auxiliary relay for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 10A with heat-resistant rated current 6A at 110V and 3A at 220V under AC-15 class. Contact configurations 9a, 7a2b, 5a4b. AC operated coil in seven designations from AC24V to AC500V. Durability and outline dimensions are the same as the standard product. Type approval number 2RY-13041. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.

21 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
SR-T9FN AC24V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC24V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC24V · Coil Rating: 24V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC24V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC24V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC24V · Coil Rating: 24V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC24V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC24V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC24V · Coil Rating: 24V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC48V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC48V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC48V · Coil Rating: 48-50V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC48V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC48V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC48V · Coil Rating: 48-50V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC48V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC48V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC48V · Coil Rating: 48-50V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC100V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC100V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC100V · Coil Rating: 100-127V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC100V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC100V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC100V · Coil Rating: 100-127V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC100V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC100V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC100V · Coil Rating: 100-127V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC200V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC200V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC200V · Coil Rating: 200-240V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC200V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC200V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC200V · Coil Rating: 200-240V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC200V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC200V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC200V · Coil Rating: 200-240V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC300V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC300V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC300V · Coil Rating: 260-300V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC300V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC300V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC300V · Coil Rating: 260-300V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC300V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC300V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC300V · Coil Rating: 260-300V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC400V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC400V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC400V · Coil Rating: 380-440V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC400V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC400V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC400V · Coil Rating: 380-440V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC400V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC400V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC400V · Coil Rating: 380-440V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC500V 9A SR-T9FN class 2 heat-resistant auxiliary relay, AC500V coil, 9a Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 9a · Coil Designation: AC500V · Coil Rating: 460-550V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC500V 7A2B SR-T9FN class 2 heat-resistant auxiliary relay, AC500V coil, 7a2b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 7a2b · Coil Designation: AC500V · Coil Rating: 460-550V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SR-T9FN AC500V 5A4B SR-T9FN class 2 heat-resistant auxiliary relay, AC500V coil, 5a4b Mitsubishi Electric Type: Class 2 heat-resistant auxiliary relay · Frame: T9 · Operation: AC operated · Contact Configuration: 5a4b · Coil Designation: AC500V · Coil Rating: 460-550V 50/60Hz · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-13041 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature