[Mitsubishi Electric] - SRE-AAU Voltage Detection Relay (Standard Detection, DC 0.1V to AC 250V, AC115-120V or AC230-240V)
Auxiliary Relays MITSUBISHI ELECTRIC

[Mitsubishi Electric] - SRE-AAU Voltage Detection Relay (Standard Detection, DC 0.1V to AC 250V, AC115-120V or AC230-240V)

Family ID: MEL-SRE-AAU

Mitsubishi Electric MS-T/N series SRE-AAU voltage detection relay for high precision detection of DC or AC overvoltage and undervoltage, with setting ranges spanning 0.1V up to 250V across eleven detection designations. Seven DC detection designations from DC 0.1 to 0.5V up to DC 50 to 250V and four AC detection designations from AC 3 to 15V up to AC 50 to 250V are available; the DC detection versions can also be used on a single phase full wave supply. Operating voltage AC115-120V or AC230-240V 50/60Hz common. Output contact 1c rated AC110V 1.5A and AC220V 1A under AC-15 class with 500,000 operation electrical durability, and DC110V 0.2A under DC-13 class with 250,000 operations. Voltage variation characteristic plus or minus 1.5 percent over 85 to 110 percent of rated operating voltage, power consumption 2VA. Surge withstand 3500V 1 by 40 microseconds on detection input and power input. A CCC certified version is available by adding CN to the model name.

22 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
SRE-AAU 0P5D SRE-AAU voltage detection relay, DC 0.1 to 0.5V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 0P5D · Detection Setting Range: DC 0.1 to 0.5V · Maximum Continuous Input Voltage: plus or minus 100V · Input Impedance: 20 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 0P5D SRE-AAUCN voltage detection relay, DC 0.1 to 0.5V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 0P5D · Detection Setting Range: DC 0.1 to 0.5V · Maximum Continuous Input Voltage: plus or minus 100V · Input Impedance: 20 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 1P5D SRE-AAU voltage detection relay, DC 0.3 to 1.5V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 1P5D · Detection Setting Range: DC 0.3 to 1.5V · Maximum Continuous Input Voltage: plus or minus 100V · Input Impedance: 50 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 1P5D SRE-AAUCN voltage detection relay, DC 0.3 to 1.5V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 1P5D · Detection Setting Range: DC 0.3 to 1.5V · Maximum Continuous Input Voltage: plus or minus 100V · Input Impedance: 50 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 005D SRE-AAU voltage detection relay, DC 1 to 5V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 005D · Detection Setting Range: DC 1 to 5V · Maximum Continuous Input Voltage: plus or minus 150V · Input Impedance: 100 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 005D SRE-AAUCN voltage detection relay, DC 1 to 5V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 005D · Detection Setting Range: DC 1 to 5V · Maximum Continuous Input Voltage: plus or minus 150V · Input Impedance: 100 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 015D SRE-AAU voltage detection relay, DC 3 to 15V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 015D · Detection Setting Range: DC 3 to 15V · Maximum Continuous Input Voltage: plus or minus 150V · Input Impedance: 100 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 015D SRE-AAUCN voltage detection relay, DC 3 to 15V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 015D · Detection Setting Range: DC 3 to 15V · Maximum Continuous Input Voltage: plus or minus 150V · Input Impedance: 100 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 050D SRE-AAU voltage detection relay, DC 10 to 50V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 050D · Detection Setting Range: DC 10 to 50V · Maximum Continuous Input Voltage: plus or minus 200V · Input Impedance: 500 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 050D SRE-AAUCN voltage detection relay, DC 10 to 50V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 050D · Detection Setting Range: DC 10 to 50V · Maximum Continuous Input Voltage: plus or minus 200V · Input Impedance: 500 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 150D SRE-AAU voltage detection relay, DC 30 to 150V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 150D · Detection Setting Range: DC 30 to 150V · Maximum Continuous Input Voltage: plus or minus 300V · Input Impedance: 800 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 150D SRE-AAUCN voltage detection relay, DC 30 to 150V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 150D · Detection Setting Range: DC 30 to 150V · Maximum Continuous Input Voltage: plus or minus 300V · Input Impedance: 800 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 250D SRE-AAU voltage detection relay, DC 50 to 250V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 250D · Detection Setting Range: DC 50 to 250V · Maximum Continuous Input Voltage: plus or minus 300V · Input Impedance: 800 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 250D SRE-AAUCN voltage detection relay, DC 50 to 250V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 250D · Detection Setting Range: DC 50 to 250V · Maximum Continuous Input Voltage: plus or minus 300V · Input Impedance: 800 kilohm · Detection Type: DC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 015A SRE-AAU voltage detection relay, AC 3 to 15V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 015A · Detection Setting Range: AC 3 to 15V · Maximum Continuous Input Voltage: AC150V · Input Impedance: 100 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 015A SRE-AAUCN voltage detection relay, AC 3 to 15V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 015A · Detection Setting Range: AC 3 to 15V · Maximum Continuous Input Voltage: AC150V · Input Impedance: 100 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 050A SRE-AAU voltage detection relay, AC 10 to 50V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 050A · Detection Setting Range: AC 10 to 50V · Maximum Continuous Input Voltage: AC200V · Input Impedance: 500 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 050A SRE-AAUCN voltage detection relay, AC 10 to 50V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 050A · Detection Setting Range: AC 10 to 50V · Maximum Continuous Input Voltage: AC200V · Input Impedance: 500 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 150A SRE-AAU voltage detection relay, AC 30 to 150V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 150A · Detection Setting Range: AC 30 to 150V · Maximum Continuous Input Voltage: AC300V · Input Impedance: 800 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 150A SRE-AAUCN voltage detection relay, AC 30 to 150V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 150A · Detection Setting Range: AC 30 to 150V · Maximum Continuous Input Voltage: AC300V · Input Impedance: 800 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAU 250A SRE-AAU voltage detection relay, AC 50 to 250V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: Standard · Detection Designation: 250A · Detection Setting Range: AC 50 to 250V · Maximum Continuous Input Voltage: AC300V · Input Impedance: 800 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input
SRE-AAUCN 250A SRE-AAUCN voltage detection relay, AC 50 to 250V detection Mitsubishi Electric Type: Standard voltage detection relay · Certification Variant: CCC certified item · Detection Designation: 250A · Detection Setting Range: AC 50 to 250V · Maximum Continuous Input Voltage: AC300V · Input Impedance: 800 kilohm · Detection Type: AC detection · Operating Voltage: AC115-120V or AC230-240V 50/60Hz common · Output Contact: 1c contact, AC-15 class AC110V 1.5A and AC220V 1A with 500,000 operation electrical durability, DC-13 class DC110V 0.2A with 250,000 operations, carrying current Ith 3A · Voltage Variation Characteristic: 85 to 110 percent of rated operating voltage, plus or minus 1.5 percent · Power Consumption: 2VA at rated operating voltage · Surge Withstand: Surge withstand 3500V 1 by 40 microseconds on detection input and power input