Mitsubishi Electric MS-T/N series SRL-T5FN class 2 heat-resistant mechanical latch auxiliary relay for distribution boards and panelboards of dedicated emergency power receiving equipment. Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve. Heat-resistant carrying current 10A with heat-resistant rated current 6A at 110V and 3A at 220V under AC-15 class. Contact configurations 5a, 4a1b, 3a2b. AC operated closing coil with tripping coil freely specified from the AC or DC designations. Durability and outline dimensions are the same as the standard product. Type approval number 2RY-14042. Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981. Coils cannot be replaced by the user because the product is a certified item. For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature.

336 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
SRL-T5FN MC-AC100V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC100V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC100V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC100V rated 100-127V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC200V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC200V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC200V rated 200-240V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC300V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC300V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC300V rated 260-350V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC400V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC400V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC400V rated 380-440V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC500V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC500V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC500V rated 460-550V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC12V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC12V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC12V rated 12V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC24V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC24V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC24V rated 24V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC100V rated 100-127V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC200V rated 200-240V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC300V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC300V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC300V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC300V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC300V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC300V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC300V rated 260-350V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC400V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC400V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC400V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC400V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC400V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC400V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC400V rated 380-440V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC500V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC500V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC500V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC500V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC500V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC500V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC500V rated 460-550V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC12V rated 12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC24V rated 24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-AC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT AC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: AC48V rated 48-50V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC12V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC12V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC12V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC12V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC12V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC12V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC12V rated DC12V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC24V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC24V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC24V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC24V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC24V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC24V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC24V rated DC24V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC48V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC48V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC48V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC48V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC48V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC48V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC48V rated DC48V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC100V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC100V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC100V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC100V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC100V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC100V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC100V rated DC100-110V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC125V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC125V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC125V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC125V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC125V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC125V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC125V rated DC120-125V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC200V 5A SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC200V, 5a Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 5a · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC200V 4A1B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC200V, 4a1b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 4a1b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SRL-T5FN MC-AC48V MT-DC200V 3A2B SRL-T5FN class 2 heat-resistant latch auxiliary relay, MC AC48V and MT DC200V, 3a2b Mitsubishi Electric Type: Class 2 heat-resistant mechanical latch auxiliary relay · Frame: T5 · Mechanism: Mechanical latch · Operation: AC operated closing coil · Contact Configuration: 3a2b · Closing Coil MC: AC48V rated 48-50V · Tripping Coil MT: DC200V rated DC200-220V · Heat Resistant Carrying Current: 10A · Heat Resistant Rated Current AC: Carry 10A, heat-resistant rated current AC-15 class 6A at 110V and 3A at 220V and 1.2A at 550V, AC-12 class 10A at 110V and 8A at 220V and 5A at 550V · Heat Resistant Rated Current DC: DC-13 class 1.5A single pole at DC48V, 0.6A single pole and 2A 2-pole series at DC110V, 0.3A single pole and 0.8A 2-pole series at DC220V, DC-12 class 8A single pole at DC48V, 5A single pole and 8A 2-pole series at DC110V, 1A single pole and 3A 2-pole series at DC220V · Durability: Same as the standard product · Type Approval Number: 2RY-14042 · Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve · Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 · Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature