Mitsubishi Electric SRLD-T5 mechanical latch auxiliary relay (keep relay), T5 frame with DC closing coil and AC trip coil. Mechanically holds the closed state after energizing the closing coil for 0.3s or longer, retaining contact position through power failures and voltage dips for memory relay use. Self-cutoff b-contacts built into the latch mechanism, twin contacts for high contact reliability, manual closing and tripping, reduced coil power consumption. Effective contact arrangements 5a, 4a1b, 3a2b. Switching frequency 1,200 ops/h, electrical durability 500,000 ops, mechanical durability 500,000 ops, open thermal current Ith 10A. Conforms to JIS C8201-5-1, IEC 60947-5-1, EN 60947-5-1, GB14048.5. IEC 35mm rail mounting.
144 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| SRLD-T5 MC-DC12V MT-AC12V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC12V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC12V MT-AC12V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC12V MT-AC12V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC12V MT-AC24V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC24V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC12V MT-AC24V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC12V MT-AC24V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC12V MT-AC48V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC48V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC12V MT-AC48V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC12V MT-AC48V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC12V MT-AC100V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC100V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC12V MT-AC100V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC12V MT-AC100V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC12V MT-AC200V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC200V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC12V MT-AC200V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC12V MT-AC200V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC12V MT-AC300V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC300V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC12V MT-AC300V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC12V MT-AC300V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC12V MT-AC400V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC400V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC12V MT-AC400V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC12V MT-AC400V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC12V MT-AC500V 5A | Mechanical latch relay SRLD-T5, close DC12V, trip AC500V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC12V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC12V MT-AC500V 4A1B | Mechanical latch relay SRLD-T5, close DC12V, trip AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC12V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC12V MT-AC500V 3A2B | Mechanical latch relay SRLD-T5, close DC12V, trip AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC12V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC24V MT-AC12V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC12V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC24V MT-AC12V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC24V MT-AC12V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC24V MT-AC24V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC24V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC24V MT-AC24V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC24V MT-AC24V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC24V MT-AC48V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC48V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC24V MT-AC48V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC24V MT-AC48V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC24V MT-AC100V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC100V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC24V MT-AC100V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC24V MT-AC100V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC24V MT-AC200V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC200V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC24V MT-AC200V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC24V MT-AC200V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC24V MT-AC300V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC300V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC24V MT-AC300V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC24V MT-AC300V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC24V MT-AC400V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC400V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC24V MT-AC400V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC24V MT-AC400V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC24V MT-AC500V 5A | Mechanical latch relay SRLD-T5, close DC24V, trip AC500V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC24V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC24V MT-AC500V 4A1B | Mechanical latch relay SRLD-T5, close DC24V, trip AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC24V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC24V MT-AC500V 3A2B | Mechanical latch relay SRLD-T5, close DC24V, trip AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC24V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC48V MT-AC12V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC12V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC48V MT-AC12V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC48V MT-AC12V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC48V MT-AC24V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC24V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC48V MT-AC24V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC48V MT-AC24V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC48V MT-AC48V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC48V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC48V MT-AC48V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC48V MT-AC48V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC48V MT-AC100V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC100V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC48V MT-AC100V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC48V MT-AC100V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC48V MT-AC200V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC200V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC48V MT-AC200V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC48V MT-AC200V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC48V MT-AC300V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC300V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC48V MT-AC300V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC48V MT-AC300V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC48V MT-AC400V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC400V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC48V MT-AC400V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC48V MT-AC400V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC48V MT-AC500V 5A | Mechanical latch relay SRLD-T5, close DC48V, trip AC500V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC48V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC48V MT-AC500V 4A1B | Mechanical latch relay SRLD-T5, close DC48V, trip AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC48V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC48V MT-AC500V 3A2B | Mechanical latch relay SRLD-T5, close DC48V, trip AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC48V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC100V MT-AC12V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC12V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC100V MT-AC12V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC100V MT-AC12V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC100V MT-AC24V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC24V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC100V MT-AC24V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC100V MT-AC24V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC100V MT-AC48V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC48V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC100V MT-AC48V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC100V MT-AC48V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC100V MT-AC100V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC100V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC100V MT-AC100V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC100V MT-AC100V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC100V MT-AC200V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC200V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC100V MT-AC200V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC100V MT-AC200V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC100V MT-AC300V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC300V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC100V MT-AC300V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC100V MT-AC300V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC100V MT-AC400V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC400V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC100V MT-AC400V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC100V MT-AC400V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC100V MT-AC500V 5A | Mechanical latch relay SRLD-T5, close DC100V, trip AC500V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC100V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC100V MT-AC500V 4A1B | Mechanical latch relay SRLD-T5, close DC100V, trip AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC100V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC100V MT-AC500V 3A2B | Mechanical latch relay SRLD-T5, close DC100V, trip AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC100V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC125V MT-AC12V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC12V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC125V MT-AC12V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC125V MT-AC12V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC125V MT-AC24V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC24V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC125V MT-AC24V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC125V MT-AC24V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC125V MT-AC48V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC48V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC125V MT-AC48V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC125V MT-AC48V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC125V MT-AC100V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC100V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC125V MT-AC100V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC125V MT-AC100V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC125V MT-AC200V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC200V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC125V MT-AC200V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC125V MT-AC200V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC125V MT-AC300V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC300V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC125V MT-AC300V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC125V MT-AC300V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC125V MT-AC400V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC400V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC125V MT-AC400V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC125V MT-AC400V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC125V MT-AC500V 5A | Mechanical latch relay SRLD-T5, close DC125V, trip AC500V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC125V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC125V MT-AC500V 4A1B | Mechanical latch relay SRLD-T5, close DC125V, trip AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC125V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC125V MT-AC500V 3A2B | Mechanical latch relay SRLD-T5, close DC125V, trip AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC125V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC200V MT-AC12V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC12V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC200V MT-AC12V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC12V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC200V MT-AC12V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC12V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC12V | ||
| SRLD-T5 MC-DC200V MT-AC24V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC24V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC200V MT-AC24V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC24V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC200V MT-AC24V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC24V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC24V | ||
| SRLD-T5 MC-DC200V MT-AC48V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC48V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC200V MT-AC48V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC48V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC200V MT-AC48V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC48V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC48V | ||
| SRLD-T5 MC-DC200V MT-AC100V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC100V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC200V MT-AC100V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC100V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC200V MT-AC100V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC100V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC100V | ||
| SRLD-T5 MC-DC200V MT-AC200V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC200V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC200V MT-AC200V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC200V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC200V MT-AC200V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC200V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC200V | ||
| SRLD-T5 MC-DC200V MT-AC300V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC300V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC200V MT-AC300V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC300V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC200V MT-AC300V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC300V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC300V | ||
| SRLD-T5 MC-DC200V MT-AC400V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC400V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC200V MT-AC400V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC400V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC200V MT-AC400V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC400V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC400V | ||
| SRLD-T5 MC-DC200V MT-AC500V 5A | Mechanical latch relay SRLD-T5, close DC200V, trip AC500V, 5a | MITSUBISHI ELECTRIC | Contacts (Effective): 5a · Closing Coil MC: DC200V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC200V MT-AC500V 4A1B | Mechanical latch relay SRLD-T5, close DC200V, trip AC500V, 4a1b | MITSUBISHI ELECTRIC | Contacts (Effective): 4a1b · Closing Coil MC: DC200V · Trip Coil MT: AC500V | ||
| SRLD-T5 MC-DC200V MT-AC500V 3A2B | Mechanical latch relay SRLD-T5, close DC200V, trip AC500V, 3a2b | MITSUBISHI ELECTRIC | Contacts (Effective): 3a2b · Closing Coil MC: DC200V · Trip Coil MT: AC500V |