{"product_id":"autonics-srhl3-series-three-phase-solid-state-relays-integrated-heatsink-type-overheat-prevention","title":"Autonics SRHL3 Series Three-Phase SSRs","description":"\u003cp class=\"ps-intro\"\u003eThe SRHL3 series three phase solid state relays with an integrated heatsink and overheat prevention enable reliable control of high-power loads for industrial equipment large motors, high-capacity heaters and more.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated input voltage : 10-30VDC, 24VAC, 90-240VAC\u003c\/li\u003e\n\u003cli\u003eRated load voltage : 24-240VAC, 48-480VAC\u003c\/li\u003e\n\u003cli\u003eRated load current : 15A, 30A, 40A, 50A, 75A\u003c\/li\u003e\n\u003cli\u003eZero cross turn-on and random turn-on models available\u003c\/li\u003e\n\u003cli\u003eDielectric strength : 2,500VAC\u003c\/li\u003e\n\u003cli\u003eOverheat prevention function : Warning output, Alarm indicator (Red LED), Alarm output\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eAutonics (Korea)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSRHL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl phase\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eAutonics official model list (autonics.com, SRHL3 series page)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1215\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 15A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1230\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 30A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1250\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 50A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1275\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 75A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4215\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 15A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4230\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 30A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4250\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 50A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4275\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 24-240VAC~ (50\/60Hz) | Rated load current: 75A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1415\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 15A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1430\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 30A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1440\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 40A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1450\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 50A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1475\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 75A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-2415\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 24VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 15A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-2430\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 24VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 30A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-2440\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 24VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 40A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-2450\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 24VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 50A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-2475\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 24VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 75A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4415\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 15A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4430\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 30A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4440\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 40A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4450\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 50A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-4475\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 90-240VAC~ | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 75A | Function: Zero cross turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1415R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 15A | Function: Random turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1430R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 30A | Function: Random turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1440R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 40A | Function: Random turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1450R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 50A | Function: Random turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRHL3-1475R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated input voltage: 10-30VDC DC | Rated load voltage: 48-480VAC~ (50\/60Hz) | Rated load current: 75A | Function: Random turn-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Autonics","offers":[{"title":"Default Title","offer_id":67530624270626,"sku":"SRHL3-1215","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/autonics-srhl3-series-three-phase-solid-state-relays-integrated-heatsink-type-overheat-prevention.jpg?v=1792060224","url":"https:\/\/prosourcemro.com\/products\/autonics-srhl3-series-three-phase-solid-state-relays-integrated-heatsink-type-overheat-prevention","provider":"ProSource MRO","version":"1.0","type":"link"}