{"product_id":"ckd-amd3-2-chemical-air-operated-valve-10mm-3-8in","title":"CKD AMD3*2 Chemical Air Operated Valve (Part2, 10 mm \/ 3\/8\" Tube)","description":"\u003cp class=\"ps-intro\"\u003eCKD AMD3*2 Part2 chemical air-operated 2-port diaphragm valve with integrated fittings for OD 10 mm and 3\/8\" tube.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eNC, NO and double-acting actuators; PFA molded or PTFE machined body (PTFE machined bodies made to order)\u003c\/li\u003e\n\u003cli\u003eOptions: ON-OFF (0), flow adjustment (1), bypass (2), flow adj. + bypass (3), indicator (6), bypass + indicator (7)\u003c\/li\u003e\n\u003cli\u003eIntegrated Super pillar, Super 300 P, F-LOCK 20A\/60, Final Lock and Flare Tek fittings\u003c\/li\u003e\n\u003cli\u003eFluid symbol (M ammonia, P nitric\/HF acid, Y high temp 5-160 C, E high temp PTFE body) is appended after the pilot-port direction; rows list the standard version\u003c\/li\u003e\n\u003cli\u003eHigh-pressure versions (suffix B: both ports 0.3 MPa, Q: 0.4 MPa) and pilot-port reinforcing ring (R) are ordered as suffixes and not expanded; bottom-mount type (X) likewise\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eChemicals, pure water, air, N2 gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e5-90 C (high-temp versions 5-160 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003eA to B 0-0.3 MPa, B to A 0-0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeat leakage\u003c\/th\u003e\n\u003ctd\u003e0 cm3\/min (water pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot port\u003c\/th\u003e\n\u003ctd\u003eRc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice\u003c\/th\u003e\n\u003ctd\u003e6.3-8 mm (Cv 0.8-1.25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBypass orifice\u003c\/th\u003e\n\u003ctd\u003e2.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass\u003c\/th\u003e\n\u003ctd\u003e0.21 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eAMD3*2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-031K-15, p. 72-83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10US-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUS-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UP-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUP-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UA-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUA-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UR-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUR-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10UK-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUK-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD312-10BUW-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NC (normally closed) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10US-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUS-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UP-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUP-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UA-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUA-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UR-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUR-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10UK-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUK-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD322-10BUW-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: NO (normally open) | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10US-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUS-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super pillar | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UP-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUP-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Super 300 P | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UA-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUA-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 20A | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UR-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUR-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, F-LOCK 60 | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10UK-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 10 mm tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUK-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Final Lock | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF only | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-1-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-1-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-1-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-1-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adjustment | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-2-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: With bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-3-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-3-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-3-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Flow adj. + bypass | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-6-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: ON-OFF, indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-7-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-7-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-7-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMD332-10BUW-8-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAction: Double acting | Connection: OD 3\/8\" tube, Flare Tek | Option: Bypass + indicator | Pilot port dir: 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524272783650,"sku":"AMD312-10US-8-0-4","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-amd3-2-chemical-air-operated-valve-10mm-3-8in.jpg?v=1791975011","url":"https:\/\/prosourcemro.com\/products\/ckd-amd3-2-chemical-air-operated-valve-10mm-3-8in","provider":"ProSource MRO","version":"1.0","type":"link"}