{"product_id":"ckd-amg303r-403r-503r-air-operated-3-port-valve-for-chemicals","title":"CKD AMG303R\/403R\/503R Air Operated 3-Port Valve for Chemicals","description":"\u003cp class=\"ps-intro\"\u003eCKD AMG303R\/403R\/503R made-to-order air-operated 3-port (NC + NO pair) diaphragm valves for chemicals and pure water, orifice 6 to 20 mm.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFluororesin construction: PVDF actuator, PTFE diaphragm, integrated tube fittings\u003c\/li\u003e\n\u003cli\u003eConnections: Super 300 type Pillar fitting (P series, UP) or F-LOCK 60 series fitting (UR), metric and inch tubes\u003c\/li\u003e\n\u003cli\u003eOrifice: AMG303R 6-10 mm, AMG403R 15-16 mm, AMG503R 20 mm; PTFE body\u003c\/li\u003e\n\u003cli\u003eActuator 00 ON-OFF with indicator or 10 with flow adjustment; A port position L or R\u003c\/li\u003e\n\u003cli\u003eSensor-equipped actuators (A1\/A3\/B1\/B3 NPN, C1\/D1 PNP; cable 1 m or 3 m) replace 00\/10 in the code and are not expanded\u003c\/li\u003e\n\u003cli\u003eMade to order; AMG403R\/503R subject to export control. Example: AMG303R-10UP-00L\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eChemicals, pure water, air, N2 gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 120 C (HF 5-80 C; F-LOCK 5-100 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure A-B \/ B-A\u003c\/th\u003e\n\u003ctd\u003e0-0.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeat leakage\u003c\/th\u003e\n\u003ctd\u003e0 (water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBack pressure\u003c\/th\u003e\n\u003ctd\u003e0-0.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating (pilot) pressure\u003c\/th\u003e\n\u003ctd\u003e0.35-0.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot port\u003c\/th\u003e\n\u003ctd\u003eRc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass\u003c\/th\u003e\n\u003ctd\u003e0.50 \/ 1.0 \/ 2.1 kg (303\/403\/503)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-03-1SK-9, p. 1192-1197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD10x8 (orif. 8) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD10x8 (orif. 8) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD10x8 (orif. 8) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD10x8 (orif. 8) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 3\/8x1\/4 in (orif. 8) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 3\/8x1\/4 in (orif. 8) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 3\/8x1\/4 in (orif. 8) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 3\/8x1\/4 in (orif. 8) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD12x10 (orif. 10) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD12x10 (orif. 10) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD12x10 (orif. 10) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 OD12x10 (orif. 10) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 1\/2x3\/8 in (orif. 10) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 1\/2x3\/8 in (orif. 10) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 1\/2x3\/8 in (orif. 10) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: Pillar S300 1\/2x3\/8 in (orif. 10) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD10x8 (orif. 7) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD10x8 (orif. 7) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD10x8 (orif. 7) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10UR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD10x8 (orif. 7) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 3\/8x1\/4 in (orif. 6) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 3\/8x1\/4 in (orif. 6) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 3\/8x1\/4 in (orif. 6) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-10BUR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 3\/8x1\/4 in (orif. 6) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD12x10 (orif. 9) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD12x10 (orif. 9) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD12x10 (orif. 9) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-12UR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 OD12x10 (orif. 9) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 1\/2x3\/8 in (orif. 9) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 1\/2x3\/8 in (orif. 9) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 1\/2x3\/8 in (orif. 9) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG303R-15BUR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG303R | Connection: F-LOCK 60 1\/2x3\/8 in (orif. 9) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: Pillar S300 3\/4x5\/8 in (orif. 16) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: Pillar S300 3\/4x5\/8 in (orif. 16) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: Pillar S300 3\/4x5\/8 in (orif. 16) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: Pillar S300 3\/4x5\/8 in (orif. 16) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: F-LOCK 60 3\/4x5\/8 in (orif. 15) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: F-LOCK 60 3\/4x5\/8 in (orif. 15) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: F-LOCK 60 3\/4x5\/8 in (orif. 15) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG403R-20BUR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG403R | Connection: F-LOCK 60 3\/4x5\/8 in (orif. 15) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 OD25x22 (orif. 20) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 OD25x22 (orif. 20) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 OD25x22 (orif. 20) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 OD25x22 (orif. 20) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUP-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 1x7\/8 in (orif. 20) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUP-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 1x7\/8 in (orif. 20) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUP-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 1x7\/8 in (orif. 20) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUP-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: Pillar S300 1x7\/8 in (orif. 20) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 OD25x22 (orif. 20) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 OD25x22 (orif. 20) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 OD25x22 (orif. 20) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25UR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 OD25x22 (orif. 20) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUR-00L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 1x7\/8 in (orif. 20) | Actuator: ON-OFF, indicator | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUR-00R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 1x7\/8 in (orif. 20) | Actuator: ON-OFF, indicator | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUR-10L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 1x7\/8 in (orif. 20) | Actuator: With flow adjustment | A port position: Left\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMG503R-25BUR-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMG503R | Connection: F-LOCK 60 1x7\/8 in (orif. 20) | Actuator: With flow adjustment | A port position: Right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524245389602,"sku":"AMG303R-10UP-00L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-amg303r-403r-503r-air-operated-3-port-valve-for-chemicals.jpg?v=1791975010","url":"https:\/\/prosourcemro.com\/products\/ckd-amg303r-403r-503r-air-operated-3-port-valve-for-chemicals","provider":"ProSource MRO","version":"1.0","type":"link"}