{"product_id":"ckd-dsc-speed-controller-with-dial-battery-spec-p4","title":"CKD DSC Speed Controller with Dial (Battery Mfg. Spec P4)","description":"\u003cp class=\"ps-intro\"\u003eCKD DSC series dial speed controller in -P4 secondary-battery-manufacturing specification, elbow push-in type, M5 and R1\/8 to R1\/2.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStructure suitable for general assembly processes of lithium-ion secondary battery manufacturing\u003c\/li\u003e\n\u003cli\u003eDial indicator on the needle shows the opening for repeatable, visual speed setting\u003c\/li\u003e\n\u003cli\u003ePush-lock needle: pull knob to unlock, push to lock\u003c\/li\u003e\n\u003cli\u003eCompact type (M5, R1\/8; 1-7 needle turns) and standard type (R1\/8-R1\/2; 1-10 turns)\u003c\/li\u003e\n\u003cli\u003eMeter-out or meter-in (I, black release ring); standard, low (L) or micro (F, compact) flow\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. operating pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMin. operating pressure\u003c\/th\u003e\n\u003ctd\u003e0.05 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 60 C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 60 C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-024SK-9, p. 766-777\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-3-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 3.2 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-3-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 3.2 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-3-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 3.2 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-3-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 3.2 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-4-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-4-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-4-F-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-4-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-4-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-4-IF-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-6-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-6-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-6-F-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-6-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-6-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-M5-6-IF-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: M5x0.8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-4-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-4-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-4-F-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-4-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-4-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-4-IF-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-6-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-6-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-6-F-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-6-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-6-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-6-IF-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Micro flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-8-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-8-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-8-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-C-6-8-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Compact | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-4-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-4-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-4-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-4-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 4 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-6-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-6-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-6-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-6-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-8-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-8-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-8-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-6-8-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/8 | Tube OD: 8 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-6-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 6 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-6-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 6 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-6-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 6 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-6-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 6 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-8-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 8 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-8-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 8 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-8-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 8 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-8-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 8 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-10-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 10 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-10-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 10 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-10-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 10 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-8-10-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/4 | Tube OD: 10 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-6-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-6-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 6 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-6-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-6-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 6 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-8-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 8 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-8-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 8 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-8-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 8 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-8-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 8 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-10-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 10 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-10-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 10 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-10-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 10 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-10-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 10 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-12-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 12 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-12-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 12 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-12-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 12 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-10-12-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R3\/8 | Tube OD: 12 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-10-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 10 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-10-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 10 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-10-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 10 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-10-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 10 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-12-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 12 mm | Control: Meter-out | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-12-L-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 12 mm | Control: Meter-out | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-12-I-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 12 mm | Control: Meter-in | Flow type: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDSC-15-12-IL-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Standard | Port: R1\/2 | Tube OD: 12 mm | Control: Meter-in | Flow type: Low flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524168417570,"sku":"DSC-C-M5-3-P4","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-dsc-speed-controller-with-dial-battery-spec-p4.jpg?v=1791974952","url":"https:\/\/prosourcemro.com\/products\/ckd-dsc-speed-controller-with-dial-battery-spec-p4","provider":"ProSource MRO","version":"1.0","type":"link"}