{"product_id":"ckd-evd-1000-digital-electro-pneumatic-regulator","title":"CKD EVD-1000 Digital Electro-Pneumatic Regulator (1\/4 Port)","description":"\u003cp class=\"ps-intro\"\u003eCKD EVD-1000 digital electro-pneumatic regulator that controls air pressure proportionally to an analog or 10-bit parallel input.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eControl ranges 0-100, 0-500 and 0-900 kPa; max flow 60 L\/min (EVD-1100) or 400 L\/min\u003c\/li\u003e\n\u003cli\u003eAnalog input 0-10 VDC, 0-5 VDC, 4-20 mA or 10-bit parallel input (8 preset points with analog types)\u003c\/li\u003e\n\u003cli\u003eOutput: 1-5 V analog or switch output with error output, NPN or PNP\u003c\/li\u003e\n\u003cli\u003eRc1\/4, G1\/4 or NPT1\/4 ports; 3-digit LED pressure display, key lock\u003c\/li\u003e\n\u003cli\u003eCable (C1\/C3, P1\/P3) and bracket (B1\/L1) options not expanded; also sold separately as EVD-\u0026lt;option\u0026gt;\u003c\/li\u003e\n\u003cli\u003eSecondary-battery spec (-P4*) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eClean compressed air (ISO 8573-1 [1:3:2])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e0.15 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e3-digit 7-segment LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinearity \/ hysteresis\u003c\/th\u003e\n\u003ctd\u003e+\/-0.3% F.S. \/ 0.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e0.3% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient \/ fluid temp.\u003c\/th\u003e\n\u003ctd\u003e5 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCode format\u003c\/th\u003e\n\u003ctd\u003eEVD-1\u0026lt;range\u0026gt;-\u0026lt;input\u0026gt;\u0026lt;port\u0026gt;\u0026lt;output\u0026gt;-\u0026lt;option\u0026gt;-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-024SK-9, p. 654-659\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-008NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-108NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-208NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1100-P08NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-008NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-108NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-208NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1500-P08NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-008NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-108NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-208NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-1900-P08NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-1900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Analog 9-core cable 1 m | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-C3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Analog 9-core cable 3 m | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-P1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Parallel 15-core cable 1 m | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-P3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Parallel 15-core cable 3 m | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: B bracket, floor mount | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-L1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L bracket, wall mount | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524167631138,"sku":"EVD-1100-008AN-3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-evd-1000-digital-electro-pneumatic-regulator.jpg?v=1791975031","url":"https:\/\/prosourcemro.com\/products\/ckd-evd-1000-digital-electro-pneumatic-regulator","provider":"ProSource MRO","version":"1.0","type":"link"}