{"product_id":"ckd-evd-3000-digital-electro-pneumatic-regulator","title":"CKD EVD-3000 Digital Electro-Pneumatic Regulator (1\/4, 3\/8 Port)","description":"\u003cp class=\"ps-intro\"\u003eCKD EVD-3000 high-flow digital electro-pneumatic regulator with 1\/4 or 3\/8 ports for proportional pressure control.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eControl ranges 0-100, 0-500 and 0-900 kPa; max flow 700 L\/min (EVD-3100) or 1500 L\/min\u003c\/li\u003e\n\u003cli\u003eAnalog input 0-10 VDC, 0-5 VDC, 4-20 mA or 10-bit parallel input\u003c\/li\u003e\n\u003cli\u003eOutput: 1-5 V analog or switch output with error output, NPN or PNP\u003c\/li\u003e\n\u003cli\u003eIN\/OUT ports Rc, G or NPT 1\/4 and 3\/8; EXH port 3\/8\u003c\/li\u003e\n\u003cli\u003eCable options as EVD-1000 (EVD-C1\/C3\/P1\/P3); brackets B3\/L3; options not expanded\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eClean compressed air (ISO 8573-1 [1:3:2])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e0.15 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e3-digit 7-segment LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinearity \/ hysteresis\u003c\/th\u003e\n\u003ctd\u003e+\/-0.3% F.S. \/ 0.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e0.3% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient \/ fluid temp.\u003c\/th\u003e\n\u003ctd\u003e5 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCode format\u003c\/th\u003e\n\u003ctd\u003eEVD-3\u0026lt;range\u0026gt;-\u0026lt;input\u0026gt;\u0026lt;port\u0026gt;\u0026lt;output\u0026gt;-\u0026lt;option\u0026gt;-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-024SK-9, p. 660-680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-008NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-010NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-108NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-110NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-208NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-210NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P08NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3100-P10NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3100 | Pressure range: 0-100 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-008NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-010NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-108NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-110NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-208NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-210NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P08NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3500-P10NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3500 | Pressure range: 0-500 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-008NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-010NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-10 VDC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-108NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-110NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 0-5 VDC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-208NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-210NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: 4-20 mA DC | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P08NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT1\/4 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10AN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10AP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10SN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10SP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: Rc3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10GAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10GAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10GSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10GSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: G3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10NAN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: 1-5 V analog, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10NAP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: 1-5 V analog, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10NSN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: Switch NPN, error NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-3900-P10NSP-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: EVD-3900 | Pressure range: 0-900 kPa | Input signal: Parallel 10 bit | Port: NPT3\/8 | Output signal: Switch PNP, error PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-B3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: B bracket, floor mount | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEVD-L3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: L bracket, wall mount | Pressure range: - | Input signal: - | Port: - | Output signal: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524167762210,"sku":"EVD-3100-008AN-3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-evd-3000-digital-electro-pneumatic-regulator.jpg?v=1791975031","url":"https:\/\/prosourcemro.com\/products\/ckd-evd-3000-digital-electro-pneumatic-regulator","provider":"ProSource MRO","version":"1.0","type":"link"}