{"product_id":"ckd-gcve2-gcvse2-modular-coolant-valve","title":"CKD GCVE2\/GCVSE2 Modular Coolant Valve (1-5 Stations)","description":"\u003cp class=\"ps-intro\"\u003eCKD GCVE2\/GCVSE2 modular air-operated 2-port coolant valves joined by O-ring and bolts into 1 to 5 station assemblies.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eModules joined with O-rings and hex socket bolts; A (threaded) and B (through-hole) bodies\u003c\/li\u003e\n\u003cli\u003eNC or NO, 0.5 \/ 1.0 \/ 1.6 MPa, OUT Rc1\/2 or Rc3\/4\u003c\/li\u003e\n\u003cli\u003eGCVE2 air operated or GCVSE2 with DIN Pg9 pilot solenoid (2G); lamp DIN box 2H optional\u003c\/li\u003e\n\u003cli\u003eNitrile (0) or fluoro rubber (B) seal; joint kits listed for adding stations\u003c\/li\u003e\n\u003cli\u003eSurge killer (S) and mounting plate (B) options; mixed modules by special order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eCoolant, non-corrosive liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid viscosity\u003c\/th\u003e\n\u003ctd\u003e500 mm2\/s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e2.0 MPa (05\/10), 6.0 MPa (16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot fluid \/ pressure\u003c\/th\u003e\n\u003ctd\u003eAir, 0.25 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot port\u003c\/th\u003e\n\u003ctd\u003eRc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIPX5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. stations\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-03-1SK-9, p. 964-969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-A-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-B-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-2-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-3-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-4-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-5-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-A-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-B-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-2-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-3-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-4-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-15A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-15A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-15A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-15A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-15A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-15A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-20A-05-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-20A-05-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-20A-10-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-20A-10-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-20A-16-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE22-5-20A-16-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVE2 air operated, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-A-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-B-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-2-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-3-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-4-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE2-5-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NC | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-A-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, threaded | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-B-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 1 station, through-hole | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-2-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 2 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-3-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 3 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-4-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 4 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-15A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-05-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-05-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-05-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-05-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-05-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-05-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 0.5 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-10-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-10-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-10-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-10-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-10-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-10-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.0 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-16-02G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-16-02G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-16-02G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Nitrile | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-16-B2G-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC100V 50\/60Hz, AC110V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-16-B2G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: AC200V 50\/60Hz, AC220V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVSE22-5-20A-16-B2G-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GCVSE2 solenoid DIN Pg9, NO | Modules: 5 stations | Port: OUT Rc3\/4, IN Rc1 | Pressure: 0 to 1.6 MPa | Seal: Fluoro rubber | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-15A-50-0-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x50 bolts, NBR O-ring | Modules: - | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: - | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-20A-60-0-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x60 bolts, NBR O-ring | Modules: - | Port: OUT Rc3\/4, IN Rc1 | Pressure: - | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-15A-50-B-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x50 bolts, FKM O-ring | Modules: - | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: - | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-20A-60-B-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x60 bolts, FKM O-ring | Modules: - | Port: OUT Rc3\/4, IN Rc1 | Pressure: - | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-15A-100-0-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x100 bolts, 2 NBR O-rings | Modules: - | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: - | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-20A-120-0-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x120 bolts, 2 NBR O-rings | Modules: - | Port: OUT Rc3\/4, IN Rc1 | Pressure: - | Seal: Nitrile | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-15A-100-B-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x100 bolts, 2 FKM O-rings | Modules: - | Port: OUT Rc1\/2, IN Rc3\/4 | Pressure: - | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCVE2-20A-120-B-JOINT-KIT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: Joint kit, M8x120 bolts, 2 FKM O-rings | Modules: - | Port: OUT Rc3\/4, IN Rc1 | Pressure: - | Seal: Fluoro rubber | Voltage: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524241031458,"sku":"GCVE2-A-15A-05-0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-gcve2-gcvse2-modular-coolant-valve.jpg?v=1791975010","url":"https:\/\/prosourcemro.com\/products\/ckd-gcve2-gcvse2-modular-coolant-valve","provider":"ProSource MRO","version":"1.0","type":"link"}