{"product_id":"ckd-ghv-medium-pressure-gas-combination-valve","title":"CKD GHV Medium Pressure Gas Combination Valve (NC, Rp1-Rp2)","description":"\u003cp class=\"ps-intro\"\u003eIntegrated double shut-off gas valve combining two solenoid valves (optionally with built-in governor) in one body for pressures up to 50 kPa.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eTwo solenoid valves in one body: about 1\/3 the footprint (50A, vs CKD conventional)\u003c\/li\u003e\n\u003cli\u003eConfigurations: G (governor built-in), N (two SVs), L (two SVs, slow open)\u003c\/li\u003e\n\u003cli\u003eFlange-changeable connection Rp1 to Rp2; flange sets GHV-FLANGE-D25 to D50\u003c\/li\u003e\n\u003cli\u003eOption E: closed-position confirmation switch\u003c\/li\u003e\n\u003cli\u003eConforms to ISO 23551-1 \/ ISO 23551-2; IP54\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia\u003c\/th\u003e\n\u003ctd\u003eCity gas, natural gas, LPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 to 50 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow\u003c\/th\u003e\n\u003ctd\u003e35 to 51 m3\/h (ANR, natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e80 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClosing time\u003c\/th\u003e\n\u003ctd\u003e1.0 s or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-03-1SK-9, p. 1050-1053\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D00-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: No flange | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D00-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: No flange | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D00-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: No flange | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D00-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: No flange | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D25-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D25-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D25-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D25-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D32-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/4 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D32-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/4 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D32-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/4 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D32-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/4 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D40-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/2 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D40-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/2 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D40-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/2 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D40-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp1-1\/2 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D50-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp2 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D50-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp2 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D50-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp2 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-G-D50-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Governor SV + SV | Connection: Rp2 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D00-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: No flange | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D00-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: No flange | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D00-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: No flange | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D00-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: No flange | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D25-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D25-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D25-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D25-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D32-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/4 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D32-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/4 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D32-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/4 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D32-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/4 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D40-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/2 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D40-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/2 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D40-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/2 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D40-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp1-1\/2 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D50-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp2 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D50-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp2 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D50-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp2 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-N-D50-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV | Connection: Rp2 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D00-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: No flange | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D00-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: No flange | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D00-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: No flange | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D00-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: No flange | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D25-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D25-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D25-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D25-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D32-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/4 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D32-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/4 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D32-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/4 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D32-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/4 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D40-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/2 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D40-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/2 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D40-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/2 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D40-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp1-1\/2 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D50-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp2 | Closed switch: No | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D50-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp2 | Closed switch: No | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D50-E-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp2 | Closed switch: Yes | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-L-D50-E-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: SV + SV (slow open) | Connection: Rp2 | Closed switch: Yes | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-FLANGE-D25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Flange set | Connection: Rp1 | Closed switch: - | Voltage: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-FLANGE-D32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Flange set | Connection: Rp1-1\/4 | Closed switch: - | Voltage: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-FLANGE-D40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Flange set | Connection: Rp1-1\/2 | Closed switch: - | Voltage: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGHV-FLANGE-D50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration: Flange set | Connection: Rp2 | Closed switch: - | Voltage: -\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524242473250,"sku":"GHV-G-D00-AC100V","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-ghv-medium-pressure-gas-combination-valve.jpg?v=1791975010","url":"https:\/\/prosourcemro.com\/products\/ckd-ghv-medium-pressure-gas-combination-valve","provider":"ProSource MRO","version":"1.0","type":"link"}