{"product_id":"ckd-gnad-diaphragm-cylinder-valve-manifold","title":"CKD GNAD Diaphragm Type Cylinder Valve Manifold (GNAD \/ GNADV)","description":"\u003cp class=\"ps-intro\"\u003eCKD GNAD\/GNADV manifold-type diaphragm cylinder valves, 2 to 10 stations, for air, inert gas, water and low vacuum.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eNC, NO and double-acting; GNADV for low vacuum\u003c\/li\u003e\n\u003cli\u003eCommon supply (C port) or individual supply (A port) sub-plate; 0 = actuator only\u003c\/li\u003e\n\u003cli\u003eStainless or aluminium sub-plate, stainless or polypropylene body, EPDM seal\u003c\/li\u003e\n\u003cli\u003eBuilt from 2-, 3- and 5-station blocks; 11 stations or more on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePort size\u003c\/th\u003e\n\u003ctd\u003eRc1\/4 (C), Rc3\/8 (A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003eGNAD 0-0.5 MPa; GNADV 1.3x10^2 to 5x10^5 Pa(abs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa (water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 50 C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.4-0.5 MPa (Rc1\/8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrifice\u003c\/th\u003e\n\u003ctd\u003e7 mm (Cv 0.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-03-1SK-9, p. 632-635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-1-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1-5-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-1-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD1V-5-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NC | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-1-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2-5-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-1-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD2V-5-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: NO | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-1-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3-5-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Air, inert gas, water | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-1-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Common supply (C port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-2-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-2-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 2 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-3-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-3-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-3-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 3 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-4-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-4-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 4 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-5-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-5-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-5-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 5 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-6-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-6-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 6 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-7-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-7-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-7-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 7 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-8-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-8-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 8 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-9-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-9-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-9-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 9 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-10-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-10-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: 10 | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-0-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ stainless \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-0-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Stainless \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNAD3V-5-0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation: Double acting | Fluid: Low vacuum (air, water) | Supply: Individual supply (A port) | Stations: Actuator only | Sub-plate \/ body \/ seal: Aluminium \/ PP body \/ EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524229038370,"sku":"GNAD1-1-2-R","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-gnad-diaphragm-cylinder-valve-manifold_2130d381-0638-4266-8f68-83b21fe9f79e.jpg?v=1791984380","url":"https:\/\/prosourcemro.com\/products\/ckd-gnad-diaphragm-cylinder-valve-manifold","provider":"ProSource MRO","version":"1.0","type":"link"}