{"product_id":"ckd-hb-fp2-high-corrosion-resistant-direct-acting-2-port-valve","title":"CKD HB-FP2 High Corrosion Resistant Direct Acting 2-Port Valve (NC)","description":"\u003cp class=\"ps-intro\"\u003eCKD HB31\/HB41-FP2 highly corrosion-resistant direct-acting normally closed 2-port solenoid valve for water, pure water and chemicals.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eHB31 Rc1\/8, Rc1\/4 (orifice 3 mm); HB41 Rc1\/4, Rc3\/8 (orifice 4 mm)\u003c\/li\u003e\n\u003cli\u003eStainless steel body, FKM seal (M)\u003c\/li\u003e\n\u003cli\u003eAC versions use diode built-in coil (5A); DC24V uses 3A coil\u003c\/li\u003e\n\u003cli\u003eIP65 equivalent\u003c\/li\u003e\n\u003cli\u003eFP2 food-processing spec: wetted materials comply with the Japanese Food Sanitation Act\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eWater, pure water, chemicals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 to 0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e2 MPa (hydraulic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeat leakage\u003c\/th\u003e\n\u003ctd\u003e0 cm3\/min (water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CC-1271K-5, p. 411-411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB31-6-3-M-5AFP2-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB31 | Port: Rc1\/8 | Orifice: 3 mm | Coil housing: Diode built-in, lead wire | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB31-6-3-M-5AFP2-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB31 | Port: Rc1\/8 | Orifice: 3 mm | Coil housing: Diode built-in, lead wire | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB31-6-3-M-3AFP2-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB31 | Port: Rc1\/8 | Orifice: 3 mm | Coil housing: Open frame, lead wire | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB31-8-3-M-5AFP2-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB31 | Port: Rc1\/4 | Orifice: 3 mm | Coil housing: Diode built-in, lead wire | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB31-8-3-M-5AFP2-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB31 | Port: Rc1\/4 | Orifice: 3 mm | Coil housing: Diode built-in, lead wire | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB31-8-3-M-3AFP2-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB31 | Port: Rc1\/4 | Orifice: 3 mm | Coil housing: Open frame, lead wire | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB41-8-5-M-5AFP2-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB41 | Port: Rc1\/4 | Orifice: 4 mm | Coil housing: Diode built-in, lead wire | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB41-8-5-M-5AFP2-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB41 | Port: Rc1\/4 | Orifice: 4 mm | Coil housing: Diode built-in, lead wire | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB41-8-5-M-3AFP2-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB41 | Port: Rc1\/4 | Orifice: 4 mm | Coil housing: Open frame, lead wire | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB41-10-5-M-5AFP2-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB41 | Port: Rc3\/8 | Orifice: 4 mm | Coil housing: Diode built-in, lead wire | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB41-10-5-M-5AFP2-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB41 | Port: Rc3\/8 | Orifice: 4 mm | Coil housing: Diode built-in, lead wire | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB41-10-5-M-3AFP2-DC24V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: HB41 | Port: Rc3\/8 | Orifice: 4 mm | Coil housing: Open frame, lead wire | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524327145762,"sku":"HB31-6-3-M-5AFP2-AC100V","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-hb-fp2-high-corrosion-resistant-direct-acting-2-port-valve_395e3f87-7e6a-442b-aa16-19cdcb1dbc5b.jpg?v=1791984458","url":"https:\/\/prosourcemro.com\/products\/ckd-hb-fp2-high-corrosion-resistant-direct-acting-2-port-valve","provider":"ProSource MRO","version":"1.0","type":"link"}