{"product_id":"ckd-just-fit-direct-acting-2-port-solenoid-valve-for-hot-water-fhb-series-single-unit","title":"CKD JUST FIT Direct Acting 2-Port Solenoid Valve for Hot Water FHB Series (Single Unit)","description":"\u003cp class=\"ps-intro\"\u003eDirect-acting poppet 2-port solenoid valve for hot water, single-unit type, from the JUST FIT range.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eNormally closed, class H equivalent coil, Rc1\/8 to Rc1\/2 ports, AC coils\u003c\/li\u003e\n\u003cli\u003eCodes give body size, port size and orifice; coil option and voltage are added when ordering\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003ehot water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil voltage\u003c\/th\u003e\n\u003ctd\u003eAC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB21-6-Z\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/8 | Orifice (mm): 1 | Cv: 0.035 | Max operating pressure differential (MPa): 1.5 | Max working pressure (MPa): 1.5 | Mass (kg): 0.16 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB21-6-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/8 | Orifice (mm): 2 | Cv: 0.15 | Max operating pressure differential (MPa): 0.7 | Max working pressure (MPa): 1.5 | Mass (kg): 0.16 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB31-6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/8 | Orifice (mm): 3 | Cv: 0.31 | Max operating pressure differential (MPa): 0.7 | Max working pressure (MPa): 1.5 | Mass (kg): 0.31 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB31-8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 3 | Cv: 0.31 | Max operating pressure differential (MPa): 0.7 | Max working pressure (MPa): 1.5 | Mass (kg): 0.31 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB31-6-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/8 | Orifice (mm): 4 | Cv: 0.54 | Max operating pressure differential (MPa): 0.4 | Max working pressure (MPa): 1.5 | Mass (kg): 0.31 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB31-8-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 4 | Cv: 0.54 | Max operating pressure differential (MPa): 0.4 | Max working pressure (MPa): 1.5 | Mass (kg): 0.31 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB31-6-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/8 | Orifice (mm): 5 | Cv: 0.75 | Max operating pressure differential (MPa): 0.25 | Max working pressure (MPa): 1.5 | Mass (kg): 0.31 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB31-8-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 5 | Cv: 0.75 | Max operating pressure differential (MPa): 0.25 | Max working pressure (MPa): 1.5 | Mass (kg): 0.31 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-8-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 4 | Cv: 0.54 | Max operating pressure differential (MPa): 0.8 | Max working pressure (MPa): 1.5 | Mass (kg): 0.51 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-10-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 4 | Cv: 0.54 | Max operating pressure differential (MPa): 0.8 | Max working pressure (MPa): 1.5 | Mass (kg): 0.51 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-8-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 5 | Cv: 0.80 | Max operating pressure differential (MPa): 0.5 | Max working pressure (MPa): 1.5 | Mass (kg): 0.51 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-10-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 5 | Cv: 0.80 | Max operating pressure differential (MPa): 0.5 | Max working pressure (MPa): 1.5 | Mass (kg): 0.51 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-8-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 7 | Cv: 1.10 | Max operating pressure differential (MPa): 0.2 | Max working pressure (MPa): 0.3 | Mass (kg): 0.51 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-10-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 7 | Cv: 1.10 | Max operating pressure differential (MPa): 0.2 | Max working pressure (MPa): 0.3 | Mass (kg): 0.51 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 10 | Cv: 1.88 | Max operating pressure differential (MPa): 0.1 | Max working pressure (MPa): 0.3 | Mass (kg): 0.6 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB41-15-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/2 | Orifice (mm): 10 | Cv: 1.88 | Max operating pressure differential (MPa): 0.1 | Max working pressure (MPa): 0.3 | Mass (kg): 0.6 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-8-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 4 | Cv: 0.54 | Max operating pressure differential (MPa): 1.1 | Max working pressure (MPa): 1.5 | Mass (kg): 0.69 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-10-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 4 | Cv: 0.54 | Max operating pressure differential (MPa): 1.1 | Max working pressure (MPa): 1.5 | Mass (kg): 0.69 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-8-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 5 | Cv: 0.80 | Max operating pressure differential (MPa): 0.7 | Max working pressure (MPa): 1.5 | Mass (kg): 0.69 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-10-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 5 | Cv: 0.80 | Max operating pressure differential (MPa): 0.7 | Max working pressure (MPa): 1.5 | Mass (kg): 0.69 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-8-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 7 | Cv: 1.10 | Max operating pressure differential (MPa): 0.3 | Max working pressure (MPa): 0.3 | Mass (kg): 0.69 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-10-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 7 | Cv: 1.10 | Max operating pressure differential (MPa): 0.3 | Max working pressure (MPa): 0.3 | Mass (kg): 0.69 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-10-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 10 | Cv: 1.88 | Max operating pressure differential (MPa): 0.12 | Max working pressure (MPa): 0.3 | Mass (kg): 0.79 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFHB51-15-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/2 | Orifice (mm): 10 | Cv: 1.88 | Max operating pressure differential (MPa): 0.12 | Max working pressure (MPa): 0.3 | Mass (kg): 0.79 | Type: NC | Fluid: hot water | Coil voltage: AC100V, AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67448931123490,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-just-fit-direct-acting-2-port-solenoid-valve-for-hot-water-fhb-series-single-unit-1.jpg?v=1791178113","url":"https:\/\/prosourcemro.com\/products\/ckd-just-fit-direct-acting-2-port-solenoid-valve-for-hot-water-fhb-series-single-unit","provider":"ProSource MRO","version":"1.0","type":"link"}