{"product_id":"ckd-magd5-magd4-air-operated-valve-for-integrated-gas-system","title":"CKD MAGD5\/MAGD4 Air Operated Valve for Integrated Gas System IAGD","description":"\u003cp class=\"ps-intro\"\u003eCKD MAGD5 (IAGD5, 1.125\") and MAGD4 (IAGD4, 1.5\") surface-mount air operated metal diaphragm valves for SEMI-standard integrated gas systems.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003e1-block D (2-port), X\/Y (3-port) and 2-block A (3-port) valve shapes\u003c\/li\u003e\n\u003cli\u003eNC\/NO operation with optional proximity sensor (open or closed signalling) per valve\u003c\/li\u003e\n\u003cli\u003eW seal (nominal 6.35) surface-mount interface; Cv 0.1 (-0) or 0.26 (-1)\u003c\/li\u003e\n\u003cli\u003eSUS316L body, Ni-Co alloy diaphragm, PCTFE seat\u003c\/li\u003e\n\u003cli\u003eMounting bolts, gaskets and actuator air fittings ordered separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eInert gas \/ process gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e1.3x10^-6 Pa(abs) to 0.99 MPa(G) (-0); to 0.7 MPa(G) (-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid \/ ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal leakage\u003c\/th\u003e\n\u003ctd\u003e2.8x10^-12 Pa.m3\/s (He) or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating air pressure\u003c\/th\u003e\n\u003ctd\u003eNC 0.4-0.6 MPa, NO 0.4-0.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterials\u003c\/th\u003e\n\u003ctd\u003eSUS316L body, Ni-Co diaphragm, PCTFE seat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailability\u003c\/th\u003e\n\u003ctd\u003eMade to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-035K, p. 80-88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01D-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01D-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01D-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01D-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01D-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01D-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01X-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01X-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01X-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01X-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01X-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01X-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01Y-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01Y-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01Y-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01Y-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01Y-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-01Y-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-21\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-23\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-31\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-35\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-36\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-41\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-42\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-43\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-46\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-51\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-52\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-54\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-61\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-62\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-64\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-02A-W-66\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-11D-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-11D-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-11D-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-11D-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-11D-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-11D-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-21\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-23\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-31\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-35\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-36\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-41\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-42\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-43\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-46\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-51\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-52\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-54\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-61\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-62\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-64\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD5-R-12A-W-66\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD5 (1.125\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01D-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01D-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01D-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01D-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01D-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01D-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01X-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01X-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01X-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01X-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01X-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01X-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block X, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01Y-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01Y-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01Y-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01Y-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01Y-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-01Y-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block Y, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-21\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-23\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-31\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-35\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-36\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when closed | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-41\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-42\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-43\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-46\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when open | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-51\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-52\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-54\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NC, sensor on when open | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-61\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-62\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NC, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-64\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NO, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NC, sensor on when open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-02A-W-66\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 2-block A, 3-port | Cv: 0.1 | V1 operation: NO, sensor on when closed | V2 operation: NO, sensor on when closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-11D-W-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NC | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-11D-W-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NO | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-11D-W-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NC, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-11D-W-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NO, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-11D-W-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NC, sensor on when open | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAGD4-R-11D-W-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem: IAGD4 (1.5\" W seal) | Valve shape: 1-block D, 2-port | Cv: 0.26 | V1 operation: NO, sensor on when closed | V2 operation: None (single valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524340941090,"sku":"MAGD5-R-01D-W-1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-magd5-magd4-air-operated-valve-for-integrated-gas-system.jpg?v=1791975177","url":"https:\/\/prosourcemro.com\/products\/ckd-magd5-magd4-air-operated-valve-for-integrated-gas-system","provider":"ProSource MRO","version":"1.0","type":"link"}