{"product_id":"ckd-mmd02-chemical-manual-valve-fitting-type","title":"CKD MMD*02 Chemical Manual Valve (Part2, Integrated Fittings)","description":"\u003cp class=\"ps-intro\"\u003eCKD MMD302\/402\/502 Part2 series manual diaphragm valves with integrated resin tube fittings for chemical and pure water lines.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSeal-stable diaphragm structure, PTFE diaphragm\u003c\/li\u003e\n\u003cli\u003eFittings: Super type Pillar, Super 300 Pillar P, F-LOCK 20A\/60, Final Lock, Flare Tech\u003c\/li\u003e\n\u003cli\u003eTube 10, 12, 25 mm and 3\/8, 1\/2, 3\/4, 1 in\u003c\/li\u003e\n\u003cli\u003eFluid symbol U (general chemicals) or P (hydrofluoric acid); X suffix = bottom mounting\u003c\/li\u003e\n\u003cli\u003eFor full open\/close use only, not for flow regulation; PTFE machined bodies made to order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003eManual diaphragm 2-port valve (open\/close only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eChemicals, pure water, air, N2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 90 C (HF over 40 C: contact CKD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0-0.4 MPa (both directions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCv\u003c\/th\u003e\n\u003ctd\u003e0.8 to 8 (by size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody\u003c\/th\u003e\n\u003ctd\u003ePFA molded or PTFE machined (per connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-031K-15, p. 168-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10US-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10US-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10US-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10US-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUS-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUS-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUS-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUS-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UP-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UP-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UP-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UP-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUP-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUP-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUP-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUP-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UA-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UA-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UA-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UA-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 10 x ID 8 mm | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUA-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUA-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUA-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUA-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 3\/8 x 1\/4 in | Orifice: 8 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UR-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UR-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UR-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UR-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUR-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 3\/8 x 1\/4 in | Orifice: 6.4 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUR-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 3\/8 x 1\/4 in | Orifice: 6.4 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUR-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 3\/8 x 1\/4 in | Orifice: 6.4 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUR-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 3\/8 x 1\/4 in | Orifice: 6.4 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UK-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UK-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UK-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10UK-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 10 x ID 8 mm | Orifice: 7.5 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUK-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 3\/8 x 1\/4 in | Orifice: 7.5 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUK-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 3\/8 x 1\/4 in | Orifice: 7.5 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUK-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 3\/8 x 1\/4 in | Orifice: 7.5 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUK-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 3\/8 x 1\/4 in | Orifice: 7.5 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUW-8-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 3\/8 x 1\/4 in | Orifice: 6.3 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUW-8-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 3\/8 x 1\/4 in | Orifice: 6.3 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUW-8-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 3\/8 x 1\/4 in | Orifice: 6.3 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-10BUW-8-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 3\/8 x 1\/4 in | Orifice: 6.3 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12US-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12US-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12US-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12US-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUS-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUS-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUS-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUS-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super type Pillar | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UP-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UP-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UP-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UP-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUP-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUP-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUP-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUP-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Super 300 Pillar P | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UA-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UA-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UA-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UA-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUA-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUA-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUA-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUA-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 20A | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UR-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 12 x ID 10 mm | Orifice: 9.5 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UR-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 12 x ID 10 mm | Orifice: 9.5 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UR-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 12 x ID 10 mm | Orifice: 9.5 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UR-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: OD 12 x ID 10 mm | Orifice: 9.5 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUR-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 1\/2 x 3\/8 in | Orifice: 9.5 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUR-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 1\/2 x 3\/8 in | Orifice: 9.5 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUR-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 1\/2 x 3\/8 in | Orifice: 9.5 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUR-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: F-LOCK 60 | Tube: 1\/2 x 3\/8 in | Orifice: 9.5 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UK-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UK-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UK-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-12UK-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: OD 12 x ID 10 mm | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUK-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUK-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUK-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUK-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Final Lock | Tube: 1\/2 x 3\/8 in | Orifice: 10 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUW-10-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 1\/2 x 3\/8 in | Orifice: 9.4 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUW-10-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 1\/2 x 3\/8 in | Orifice: 9.4 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUW-10-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 1\/2 x 3\/8 in | Orifice: 9.4 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD302-15BUW-10-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD302 | Fitting: Flare Tech | Tube: 1\/2 x 3\/8 in | Orifice: 9.4 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUS-16-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super type Pillar | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUS-16-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super type Pillar | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUS-16-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super type Pillar | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUS-16-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super type Pillar | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUP-16-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super 300 Pillar P | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUP-16-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super 300 Pillar P | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUP-16-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super 300 Pillar P | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUP-16-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Super 300 Pillar P | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUA-16-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 20A | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUA-16-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 20A | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUA-16-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 20A | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUA-16-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 20A | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUR-16-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 60 | Tube: 3\/4 x 5\/8 in | Orifice: 15.9 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUR-16-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 60 | Tube: 3\/4 x 5\/8 in | Orifice: 15.9 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUR-16-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 60 | Tube: 3\/4 x 5\/8 in | Orifice: 15.9 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUR-16-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: F-LOCK 60 | Tube: 3\/4 x 5\/8 in | Orifice: 15.9 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUK-16-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Final Lock | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUK-16-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Final Lock | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUK-16-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Final Lock | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUK-16-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Final Lock | Tube: 3\/4 x 5\/8 in | Orifice: 16 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUW-16-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Flare Tech | Tube: 3\/4 x 5\/8 in | Orifice: 14.7 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUW-16-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Flare Tech | Tube: 3\/4 x 5\/8 in | Orifice: 14.7 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUW-16-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Flare Tech | Tube: 3\/4 x 5\/8 in | Orifice: 14.7 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD402-20BUW-16-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD402 | Fitting: Flare Tech | Tube: 3\/4 x 5\/8 in | Orifice: 14.7 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25US-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25US-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25US-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25US-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUS-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUS-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUS-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUS-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super type Pillar | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UP-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UP-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UP-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UP-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUP-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUP-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUP-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUP-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Super 300 Pillar P | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUA-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 20A | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUA-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 20A | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUA-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 20A | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUA-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 20A | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UR-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UR-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UR-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UR-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUR-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUR-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUR-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUR-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: F-LOCK 60 | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UK-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UK-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UK-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25UK-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: OD 25 x ID 22 mm | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUK-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUK-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUK-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUK-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Final Lock | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUW-20-U\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Flare Tech | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUW-20-UX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Flare Tech | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: General chemicals | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUW-20-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Flare Tech | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMMD502-25BUW-20-PX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: MMD502 | Fitting: Flare Tech | Tube: 1 x 7\/8 in | Orifice: 20 mm | Fluid: Hydrofluoric acid | Mounting: Bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524274913570,"sku":"MMD302-10US-8-U","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-mmd02-chemical-manual-valve-fitting-type.jpg?v=1791975177","url":"https:\/\/prosourcemro.com\/products\/ckd-mmd02-chemical-manual-valve-fitting-type","provider":"ProSource MRO","version":"1.0","type":"link"}