{"product_id":"ckd-mn4gd2-block-manifold-valve-blocks","title":"CKD MN4GD2 Block Manifold Valve Blocks (Individual Wiring, Direct)","description":"\u003cp class=\"ps-intro\"\u003eCKD MN3GD2\/MN4GD2 individual-wiring block manifold (direct piping) valve blocks with mounted valve (N-prefixed) and the matching solenoid valves, as full order codes.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSplit resin block construction: stations can be added or removed freely; up to 24 stations (20 for size 2)\u003c\/li\u003e\n\u003cli\u003eValve block codes N4GD2... include valve, block and A\/B port; solenoid valve only codes end in 9R\u003c\/li\u003e\n\u003cli\u003eWiring: grommet (DC only), E connector with or without lamp\/surge killer, socket-less E connector, DIN terminal box (size 2)\u003c\/li\u003e\n\u003cli\u003eOptions H (exhaust malfunction prevention), A (ozone\/coolant resistant), F (A\/B filter) and lead-wire lengths E00-E03\/E20-E23, EJ connectors, E1\/E3 are orderable but not listed\u003c\/li\u003e\n\u003cli\u003eManifold assembly codes MN4GD280R-[port]-[wiring]-[stations]-[voltage] are built from these blocks via the manifold specification sheet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold\u003c\/th\u003e\n\u003ctd\u003eBlock manifold, individual wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePiping\u003c\/th\u003e\n\u003ctd\u003eDirect Piping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003ePilot operated soft spool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0.2 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temp.\u003c\/th\u003e\n\u003ctd\u003e-5 to 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-023SK-9, p. 686-697, 738-739\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD210R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD219R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2110R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2119R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: 2-pos single N.O. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GD2660R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GD2 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GD2669R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GD2 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD210R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD219R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos single | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD220R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD229R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 2-pos double | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD230R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD239R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos all ports blocked | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD240R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD249R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GD250R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GD2 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C4-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C6-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-C8-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø8 push-in | Port form: Straight | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-B-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-B-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-B-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-B-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-BN-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-BN-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: AC200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-BN-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GD259R-06-BN-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GD2 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: Rc1\/8 | Port form: Female thread | Wiring: DIN terminal, no box | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524135420194,"sku":"N3GD210R-C4-3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-mn4gd2-block-manifold-valve-blocks.jpg?v=1791975178","url":"https:\/\/prosourcemro.com\/products\/ckd-mn4gd2-block-manifold-valve-blocks","provider":"ProSource MRO","version":"1.0","type":"link"}