{"product_id":"ckd-mn4ge1-block-manifold-valve-blocks","title":"CKD MN4GE1 Block Manifold Valve Blocks (Individual Wiring, Base)","description":"\u003cp class=\"ps-intro\"\u003eCKD MN3GE1\/MN4GE1 individual-wiring block manifold (base piping) valve blocks with mounted valve (N-prefixed) and the matching solenoid valves, as full order codes.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSplit resin block construction: stations can be added or removed freely; up to 24 stations (20 for size 2)\u003c\/li\u003e\n\u003cli\u003eValve block codes N4GE1... include valve, block and A\/B port; solenoid valve only codes end in 9R\u003c\/li\u003e\n\u003cli\u003eWiring: grommet (DC only), E connector with or without lamp\/surge killer, socket-less E connector\u003c\/li\u003e\n\u003cli\u003eOptions H (exhaust malfunction prevention), A (ozone\/coolant resistant), F (A\/B filter) and lead-wire lengths E00-E03\/E20-E23, EJ connectors, E1\/E3 are orderable but not listed\u003c\/li\u003e\n\u003cli\u003eManifold assembly codes MN4GE180R-[port]-[wiring]-[stations]-[voltage] are built from these blocks via the manifold specification sheet\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold\u003c\/th\u003e\n\u003ctd\u003eBlock manifold, individual wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePiping\u003c\/th\u003e\n\u003ctd\u003eBase Piping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperation\u003c\/th\u003e\n\u003ctd\u003ePilot operated soft spool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0.2 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temp.\u003c\/th\u003e\n\u003ctd\u003e-5 to 55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-023SK-9, p. 686-689, 698-705, 740-741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CL6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN3GE1660R-CD6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N3GE1 valve block | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GE1669R-00-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GE1 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GE1669R-00-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GE1 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GE1669R-00-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GE1 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GE1669R-00-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GE1 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GE1669R-00-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GE1 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3GE1669R-00-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 3GE1 valve only | Switching: Dual 3-port N.C.\/N.C. | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NC-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C4NO-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NC-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6NO-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NC-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL4NO-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NC-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CL6NO-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow up, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NC-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD4NO-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø4 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NC-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, B plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-CD6NO-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Elbow down, A plugged | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE120R-CD6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos double | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE129R-00-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos double | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE129R-00-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos double | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE129R-00-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos double | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE129R-00-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos double | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE129R-00-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos double | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE129R-00-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos double | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE130R-CD6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos all ports blocked | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE139R-00-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos all ports blocked | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE139R-00-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos all ports blocked | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE139R-00-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos all ports blocked | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE139R-00-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos all ports blocked | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE139R-00-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos all ports blocked | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE139R-00-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos all ports blocked | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE140R-CD6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos A\/B\/R connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE149R-00-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE149R-00-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE149R-00-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE149R-00-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE149R-00-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE149R-00-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos A\/B\/R connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-C6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD4-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø4 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: Grommet lead wire 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E0-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E0-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E0-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, 300 mm lead | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E2-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E2-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E2-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, 300 mm | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE150R-CD6-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 3-pos P\/A\/B connection | A\/B fitting: ø6 push-in | Port form: Elbow down | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE159R-00-E0N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE159R-00-E0N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE159R-00-E0N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E connector, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE159R-00-E2N-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: AC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE159R-00-E2N-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE159R-00-E2N-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 3-pos P\/A\/B connection | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: E conn., lamp+surge, no socket | Voltage: DC12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4GE110R-C6-H-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: N4GE1 valve block | Switching: 2-pos single | A\/B fitting: ø6 push-in | Port form: Straight | Wiring: Grommet + option H | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4GE119R-00-H-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: 4GE1 valve only | Switching: 2-pos single | A\/B fitting: None (on base) | Port form: Base-mount valve | Wiring: Grommet + option H | Voltage: DC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524135518498,"sku":"N3GE1660R-C4-3","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-mn4ge1-block-manifold-valve-blocks.jpg?v=1791975178","url":"https:\/\/prosourcemro.com\/products\/ckd-mn4ge1-block-manifold-valve-blocks","provider":"ProSource MRO","version":"1.0","type":"link"}