{"product_id":"ckd-multilex-direct-acting-2-port-solenoid-valve-manifold-actuator-gab312-gab352-gab412-gab452-series-nc","title":"CKD MULTILEX Direct Acting 2-Port Solenoid Valve Manifold\/Actuator GAB312, GAB352, GAB412, GAB452 Series (NC)","description":"\u003cp class=\"ps-intro\"\u003eManifold-mount actuator version of the MULTILEX AB31\/AB41 direct-acting 2-port solenoid valve.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eNormally closed, for air, low vacuum, water, kerosene and oil\u003c\/li\u003e\n\u003cli\u003eCodes give model and orifice; port sizes, station count, coil option and voltage are added when ordering\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eair, low vacuum, water, kerosene, oil (standard); hot water, steam (option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil voltage\u003c\/th\u003e\n\u003ctd\u003eAC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB312-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 1.5 | Max op. pressure diff. air AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. oil AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB352-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 1.5 | Max op. pressure diff. air AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. oil AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB312-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 2.0 | Max op. pressure diff. air AC\/DC (MPa): 1.5\/1.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 1.5\/1.5 | Max op. pressure diff. oil AC\/DC (MPa): 1.5\/1.5 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB352-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 2.0 | Max op. pressure diff. air AC\/DC (MPa): 1.5\/1.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 1.5\/1.5 | Max op. pressure diff. oil AC\/DC (MPa): 1.5\/1.5 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB312-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.0 | Max op. pressure diff. air AC\/DC (MPa): 1.0\/0.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.7\/0.5 | Max op. pressure diff. oil AC\/DC (MPa): 0.5\/0.5 | Max op. pressure diff. steam AC (MPa): 0.7 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB352-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.0 | Max op. pressure diff. air AC\/DC (MPa): 1.0\/0.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.7\/0.5 | Max op. pressure diff. oil AC\/DC (MPa): 0.5\/0.5 | Max op. pressure diff. steam AC (MPa): 0.7 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB312-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.5 | Max op. pressure diff. air AC\/DC (MPa): 0.6\/0.4 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.5\/0.4 | Max op. pressure diff. oil AC\/DC (MPa): 0.4\/0.4 | Max op. pressure diff. steam AC (MPa): 0.5 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB352-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.5 | Max op. pressure diff. air AC\/DC (MPa): 0.6\/0.4 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.5\/0.4 | Max op. pressure diff. oil AC\/DC (MPa): 0.4\/0.4 | Max op. pressure diff. steam AC (MPa): 0.5 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB312-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 4.0 | Max op. pressure diff. air AC\/DC (MPa): 0.4\/0.25 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.3\/0.25 | Max op. pressure diff. oil AC\/DC (MPa): 0.25\/0.25 | Max op. pressure diff. steam AC (MPa): 0.3 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB352-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 4.0 | Max op. pressure diff. air AC\/DC (MPa): 0.4\/0.25 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.3\/0.25 | Max op. pressure diff. oil AC\/DC (MPa): 0.25\/0.25 | Max op. pressure diff. steam AC (MPa): 0.3 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB312-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 5.0 | Max op. pressure diff. air AC\/DC (MPa): 0.2\/0.15 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.15\/0.15 | Max op. pressure diff. oil AC\/DC (MPa): 0.15\/0.15 | Max op. pressure diff. steam AC (MPa): 0.15 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB352-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 5.0 | Max op. pressure diff. air AC\/DC (MPa): 0.2\/0.15 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.15\/0.15 | Max op. pressure diff. oil AC\/DC (MPa): 0.15\/0.15 | Max op. pressure diff. steam AC (MPa): 0.15 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 1.5 | Max op. pressure diff. air AC\/DC (MPa): 5.0\/4.0 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 4.5\/4.0 | Max op. pressure diff. oil AC\/DC (MPa): 4.0\/4.0 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 1.5 | Max op. pressure diff. air AC\/DC (MPa): 5.0\/4.0 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 4.5\/4.0 | Max op. pressure diff. oil AC\/DC (MPa): 4.0\/4.0 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 2.0 | Max op. pressure diff. air AC\/DC (MPa): 3.0\/2.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 2.7\/2.5 | Max op. pressure diff. oil AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 2.0 | Max op. pressure diff. air AC\/DC (MPa): 3.0\/2.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 2.7\/2.5 | Max op. pressure diff. oil AC\/DC (MPa): 2.5\/2.5 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.0 | Max op. pressure diff. air AC\/DC (MPa): 1.5\/0.9 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 1.3\/0.9 | Max op. pressure diff. oil AC\/DC (MPa): 0.9\/0.9 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.0 | Max op. pressure diff. air AC\/DC (MPa): 1.5\/0.9 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 1.3\/0.9 | Max op. pressure diff. oil AC\/DC (MPa): 0.9\/0.9 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.5 | Max op. pressure diff. air AC\/DC (MPa): 1.2\/0.6 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.9\/0.6 | Max op. pressure diff. oil AC\/DC (MPa): 0.6\/0.6 | Max op. pressure diff. steam AC (MPa): 0.9 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.5 | Max op. pressure diff. air AC\/DC (MPa): 1.2\/0.6 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.9\/0.6 | Max op. pressure diff. oil AC\/DC (MPa): 0.6\/0.6 | Max op. pressure diff. steam AC (MPa): 0.9 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 4.0 | Max op. pressure diff. air AC\/DC (MPa): 1.0\/0.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.7\/0.5 | Max op. pressure diff. oil AC\/DC (MPa): 0.5\/0.5 | Max op. pressure diff. steam AC (MPa): 0.7 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 4.0 | Max op. pressure diff. air AC\/DC (MPa): 1.0\/0.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.7\/0.5 | Max op. pressure diff. oil AC\/DC (MPa): 0.5\/0.5 | Max op. pressure diff. steam AC (MPa): 0.7 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 5.0 | Max op. pressure diff. air AC\/DC (MPa): 0.6\/0.25 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.4\/0.25 | Max op. pressure diff. oil AC\/DC (MPa): 0.25\/0.25 | Max op. pressure diff. steam AC (MPa): 0.4 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 5.0 | Max op. pressure diff. air AC\/DC (MPa): 0.6\/0.25 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.4\/0.25 | Max op. pressure diff. oil AC\/DC (MPa): 0.25\/0.25 | Max op. pressure diff. steam AC (MPa): 0.4 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB412-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 7.0 | Max op. pressure diff. air AC\/DC (MPa): 0.25\/0.1 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.2\/0.1 | Max op. pressure diff. oil AC\/DC (MPa): 0.15\/0.1 | Max op. pressure diff. steam AC (MPa): 0.2 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB452-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 7.0 | Max op. pressure diff. air AC\/DC (MPa): 0.25\/0.1 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.2\/0.1 | Max op. pressure diff. oil AC\/DC (MPa): 0.15\/0.1 | Max op. pressure diff. steam AC (MPa): 0.2 | Type: NC | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67448931320098,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-multilex-direct-acting-2-port-solenoid-valve-manifold-actuator-gab312-gab352-gab412-gab452-series-nc-1.jpg?v=1791178527","url":"https:\/\/prosourcemro.com\/products\/ckd-multilex-direct-acting-2-port-solenoid-valve-manifold-actuator-gab312-gab352-gab412-gab452-series-nc","provider":"ProSource MRO","version":"1.0","type":"link"}