{"product_id":"ckd-multilex-direct-acting-2-port-solenoid-valve-manifold-actuator-gab422-series-no","title":"CKD MULTILEX Direct Acting 2-Port Solenoid Valve Manifold\/Actuator GAB422 Series (NO)","description":"\u003cp class=\"ps-intro\"\u003eManifold-mount actuator version of the MULTILEX AB42 normally open direct-acting 2-port solenoid valve with common supply (C port pressurized).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFor air, low vacuum, water, kerosene and oil\u003c\/li\u003e\n\u003cli\u003eCodes give model and orifice; ports, station count, coil and voltage are added when ordering\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax working pressure (MPa)\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator mass (kg)\u003c\/th\u003e\n\u003ctd\u003e0.47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eair, low vacuum, water, kerosene, oil (standard); hot water, steam (option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil voltage\u003c\/th\u003e\n\u003ctd\u003eAC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 1.5 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 2.0\/2.0 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 2.0 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 1.0\/1.0 | Max op. pressure diff. steam AC (MPa): 1.0 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.0 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 0.7\/0.7 | Max op. pressure diff. steam AC (MPa): 0.7 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 3.5 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 0.5\/0.5 | Max op. pressure diff. steam AC (MPa): 0.5 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 4.0 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 0.4\/0.4 | Max op. pressure diff. steam AC (MPa): 0.4 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 5.0 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 0.25\/0.25 | Max op. pressure diff. steam AC (MPa): 0.25 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGAB422-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOrifice (mm): 7.0 | Max op. pressure diff. air\/water\/oil AC\/DC (MPa): 0.15\/0.15 | Max op. pressure diff. steam AC (MPa): 0.15 | Type: NO | Max working pressure (MPa): 2 | Actuator mass (kg): 0.47 | Fluid: air, low vacuum, water, kerosene, oil (standard); hot water, steam (option) | Coil voltage: AC100V, AC200V, DC12V, DC24V, DC48V, DC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67448931352866,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-multilex-direct-acting-2-port-solenoid-valve-manifold-actuator-gab422-series-no-1.jpg?v=1791178526","url":"https:\/\/prosourcemro.com\/products\/ckd-multilex-direct-acting-2-port-solenoid-valve-manifold-actuator-gab422-series-no","provider":"ProSource MRO","version":"1.0","type":"link"}