{"product_id":"ckd-multilex-explosion-proof-direct-acting-2-port-solenoid-valve-ab41ex4-series-ex-d-iib-t4-nc","title":"CKD MULTILEX Explosion-Proof Direct Acting 2-Port Solenoid Valve AB41EX4 Series (Ex d IIB T4, NC)","description":"\u003cp class=\"ps-intro\"\u003eFlameproof (Ex d IIB T4) direct-acting 2-port solenoid valve from the MULTILEX range for hazardous locations.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eNormally closed, Rc1\/4 or Rc3\/8 ports, IP65 equivalent, for air, low vacuum, water, kerosene and oil\u003c\/li\u003e\n\u003cli\u003eCodes give port and orifice; seal, coil and voltage options are added when ordering\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax working pressure (MPa)\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass (kg)\u003c\/th\u003e\n\u003ctd\u003e1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion protection\u003c\/th\u003e\n\u003ctd\u003eflameproof Ex d IIB T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eair, low vacuum, water, kerosene, oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil voltage\u003c\/th\u003e\n\u003ctd\u003eAC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 1.5 | Max op. pressure diff. air AC\/DC (MPa): 5.0\/4.0 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 4.5\/4.0 | Max op. pressure diff. oil AC\/DC (MPa): 4.0\/4.0 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 1.5 | Max op. pressure diff. air AC\/DC (MPa): 5.0\/4.0 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 4.5\/4.0 | Max op. pressure diff. oil AC\/DC (MPa): 4.0\/4.0 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 2.0 | Max op. pressure diff. air AC\/DC (MPa): 3.0\/2.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 2.7\/2.5 | Max op. pressure diff. oil AC\/DC (MPa): 2.5\/2.5 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 2.0 | Max op. pressure diff. air AC\/DC (MPa): 3.0\/2.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 2.7\/2.5 | Max op. pressure diff. oil AC\/DC (MPa): 2.5\/2.5 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 3.0 | Max op. pressure diff. air AC\/DC (MPa): 1.5\/0.9 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 1.3\/0.9 | Max op. pressure diff. oil AC\/DC (MPa): 0.9\/0.9 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 3.0 | Max op. pressure diff. air AC\/DC (MPa): 1.5\/0.9 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 1.3\/0.9 | Max op. pressure diff. oil AC\/DC (MPa): 0.9\/0.9 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 3.5 | Max op. pressure diff. air AC\/DC (MPa): 1.2\/0.6 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.9\/0.6 | Max op. pressure diff. oil AC\/DC (MPa): 0.6\/0.6 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 3.5 | Max op. pressure diff. air AC\/DC (MPa): 1.2\/0.6 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.9\/0.6 | Max op. pressure diff. oil AC\/DC (MPa): 0.6\/0.6 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 4.0 | Max op. pressure diff. air AC\/DC (MPa): 1.0\/0.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.7\/0.5 | Max op. pressure diff. oil AC\/DC (MPa): 0.5\/0.5 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 4.0 | Max op. pressure diff. air AC\/DC (MPa): 1.0\/0.5 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.7\/0.5 | Max op. pressure diff. oil AC\/DC (MPa): 0.5\/0.5 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 5.0 | Max op. pressure diff. air AC\/DC (MPa): 0.6\/0.25 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.4\/0.25 | Max op. pressure diff. oil AC\/DC (MPa): 0.25\/0.25 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 5.0 | Max op. pressure diff. air AC\/DC (MPa): 0.6\/0.25 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.4\/0.25 | Max op. pressure diff. oil AC\/DC (MPa): 0.25\/0.25 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-02-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc1\/4 | Orifice (mm): 7.0 | Max op. pressure diff. air AC\/DC (MPa): 0.25\/0.1 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.2\/0.1 | Max op. pressure diff. oil AC\/DC (MPa): 0.15\/0.1 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAB41EX4-03-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort: Rc3\/8 | Orifice (mm): 7.0 | Max op. pressure diff. air AC\/DC (MPa): 0.25\/0.1 | Max op. pressure diff. water\/kerosene AC\/DC (MPa): 0.2\/0.1 | Max op. pressure diff. oil AC\/DC (MPa): 0.15\/0.1 | Type: NC | Max working pressure (MPa): 5 | Mass (kg): 1.2 | Explosion protection: flameproof Ex d IIB T4 | Fluid: air, low vacuum, water, kerosene, oil | Coil voltage: AC100V, AC200V (option DC12V, DC24V, DC48V, DC100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67448932040994,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-multilex-explosion-proof-direct-acting-2-port-solenoid-valve-ab41ex4-series-ex-d-iib-t4-nc-1.jpg?v=1791178527","url":"https:\/\/prosourcemro.com\/products\/ckd-multilex-explosion-proof-direct-acting-2-port-solenoid-valve-ab41ex4-series-ex-d-iib-t4-nc","provider":"ProSource MRO","version":"1.0","type":"link"}