{"product_id":"ckd-precision-regulator-rp1000-rp2000-series-clean-spec-p70","title":"CKD Precision Regulator RP1000\/RP2000 Series (Clean Spec P70)","description":"\u003cp class=\"ps-intro\"\u003ePrecision regulators for clean-room use with exhaust-treatment (P70) construction.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRP1000 (Rc1\/4) offers set ranges up to 0.2, 0.4 or 0.7 MPa with sensitivity within 0.1% of full span; RP2000 (Rc1\/4 or Rc3\/8) covers 0.03-0.85 MPa\u003c\/li\u003e\n\u003cli\u003eVersions with attached pressure gauge are available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMax working pressure (MPa)\u003c\/th\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003ewithin +\/-0.5% of full span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge port\u003c\/th\u003e\n\u003ctd\u003eRc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient\/fluid temp (C)\u003c\/th\u003e\n\u003ctd\u003e-5 to 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClean spec\u003c\/th\u003e\n\u003ctd\u003eP70 (exhaust treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-02-P70\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 1.3 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-02-P70-GX49\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 1.3 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P02-P70 (brass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-02-P70-GY49\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.003-0.2 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 1.3 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P02-P94 (stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-04-P70\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 3.4 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-04-P70-GX49\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 3.4 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P04-P70 (brass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-04-P70-GY49\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.005-0.4 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 3.4 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P04-P94 (stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-07-P70\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 3.4 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-07-P70-GX49\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 3.4 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P10-P70 (brass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP1000-8-07-P70-GY49\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Set pressure range (MPa): 0.005-0.7 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.1% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 3.4 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 250 | Clean spec: P70 (exhaust treatment) | Attachment: Pressure gauge G49D-6-P10-P94 (stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP2000-8-08-P70\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc1\/4 | Exhaust port: Rc3\/8 | Set pressure range (MPa): 0.03-0.85 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.2% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 5 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 470 | Clean spec: P70 (exhaust treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRP2000-10-08-P70\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePort size: Rc3\/8 | Exhaust port: Rc3\/8 | Set pressure range (MPa): 0.03-0.85 | Max working pressure (MPa): 1.0 | Sensitivity: within 0.2% of full span | Repeatability: within +\/-0.5% of full span | Air consumption (L\/min ANR): 5 or less | Gauge port: Rc1\/8 | Ambient\/fluid temp (C): -5 to 50 | Mass (g): 470 | Clean spec: P70 (exhaust treatment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67448936923426,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-precision-regulator-rp1000-rp2000-series-clean-spec-p70-1.jpg?v=1791178536","url":"https:\/\/prosourcemro.com\/products\/ckd-precision-regulator-rp1000-rp2000-series-clean-spec-p70","provider":"ProSource MRO","version":"1.0","type":"link"}