{"product_id":"ckd-su-sd-d-w-fp1-super-dryer-unit-food-grade","title":"CKD SU300D\/SU400D\/SD300D\/SD400D-W-FP1 Super Dryer (Food Grade)","description":"\u003cp class=\"ps-intro\"\u003eCKD D-series high-performance slim-body super dryers and units for installation inside equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFP1 food-processing series using NSF H1 registered grease\u003c\/li\u003e\n\u003cli\u003eHollow-fibre membrane dryer, outlet atmospheric dew point -20 C\u003c\/li\u003e\n\u003cli\u003eUnits C1 (mist filter + dryer), C2 (adds air filter and differential gauge), C3 (adds regulator and gauge); SD dryer alone\u003c\/li\u003e\n\u003cli\u003eInlet pressure code 05 (below 0.7 MPa) or 07 (0.7 MPa or more)\u003c\/li\u003e\n\u003cli\u003eOptions E (collected purge exhaust), X1 (reverse IN\/OUT), B (C bracket, SD) not multiplied\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInlet pressure range\u003c\/th\u003e\n\u003ctd\u003e0.4 to 1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInlet\/ambient temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutlet dew point\u003c\/th\u003e\n\u003ctd\u003e-20 C (atmospheric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOil mist filter\u003c\/th\u003e\n\u003ctd\u003e0.1 mg\/m3 (approx. 0.1 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CC-1271K-5, p. 318-319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU301D-05-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU301D unit | Inlet pressure: Below 0.7 MPa | Configuration: Mist filter + dryer | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU301D-05-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU301D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist filter + dryer | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU301D-05-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU301D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist + dryer + regulator | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD301D-05-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD301D dryer | Inlet pressure: Below 0.7 MPa | Configuration: Super dryer only | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU301D-07-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU301D unit | Inlet pressure: 0.7 MPa or more | Configuration: Mist filter + dryer | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU301D-07-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU301D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist filter + dryer | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU301D-07-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU301D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist + dryer + regulator | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD301D-07-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD301D dryer | Inlet pressure: 0.7 MPa or more | Configuration: Super dryer only | Inlet flow: 125 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU302D-05-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU302D unit | Inlet pressure: Below 0.7 MPa | Configuration: Mist filter + dryer | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU302D-05-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU302D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist filter + dryer | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU302D-05-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU302D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist + dryer + regulator | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD302D-05-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD302D dryer | Inlet pressure: Below 0.7 MPa | Configuration: Super dryer only | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU302D-07-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU302D unit | Inlet pressure: 0.7 MPa or more | Configuration: Mist filter + dryer | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU302D-07-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU302D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist filter + dryer | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU302D-07-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU302D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist + dryer + regulator | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD302D-07-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD302D dryer | Inlet pressure: 0.7 MPa or more | Configuration: Super dryer only | Inlet flow: 250 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU401D-05-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU401D unit | Inlet pressure: Below 0.7 MPa | Configuration: Mist filter + dryer | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU401D-05-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU401D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist filter + dryer | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU401D-05-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU401D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist + dryer + regulator | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD401D-05-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD401D dryer | Inlet pressure: Below 0.7 MPa | Configuration: Super dryer only | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU401D-07-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU401D unit | Inlet pressure: 0.7 MPa or more | Configuration: Mist filter + dryer | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU401D-07-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU401D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist filter + dryer | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU401D-07-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU401D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist + dryer + regulator | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD401D-07-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD401D dryer | Inlet pressure: 0.7 MPa or more | Configuration: Super dryer only | Inlet flow: 500 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU402D-05-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU402D unit | Inlet pressure: Below 0.7 MPa | Configuration: Mist filter + dryer | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU402D-05-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU402D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist filter + dryer | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU402D-05-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU402D unit | Inlet pressure: Below 0.7 MPa | Configuration: Filter + mist + dryer + regulator | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD402D-05-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD402D dryer | Inlet pressure: Below 0.7 MPa | Configuration: Super dryer only | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU402D-07-W-C1-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU402D unit | Inlet pressure: 0.7 MPa or more | Configuration: Mist filter + dryer | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU402D-07-W-C2-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU402D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist filter + dryer | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSU402D-07-W-C3-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SU402D unit | Inlet pressure: 0.7 MPa or more | Configuration: Filter + mist + dryer + regulator | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD402D-07-W-FP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: SD402D dryer | Inlet pressure: 0.7 MPa or more | Configuration: Super dryer only | Inlet flow: 750 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524324032802,"sku":"SU301D-05-W-C1-FP1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-su-sd-d-w-fp1-super-dryer-unit-food-grade.jpg?v=1791975301","url":"https:\/\/prosourcemro.com\/products\/ckd-su-sd-d-w-fp1-super-dryer-unit-food-grade","provider":"ProSource MRO","version":"1.0","type":"link"}