{"product_id":"ckd-ugps3-digital-gap-switch-unit","title":"CKD UGPS3 Digital Gap Switch Unit (with Valve and Regulator)","description":"\u003cp class=\"ps-intro\"\u003eCKD UGPS3 general-purpose unit combining 1-6 GPS3 digital gap switches with a needle-equipped solenoid valve and pressure regulator.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAssembled with R1000 low-pressure regulator and GPS2-AB3X-2H-FL-DC24V needle solenoid valve\u003c\/li\u003e\n\u003cli\u003e1-6 gap switch stations; regulator\/valve assembled on right or left\u003c\/li\u003e\n\u003cli\u003eShort or wide detection range; NPN, PNP or IO-Link\u003c\/li\u003e\n\u003cli\u003eSupply port Rc1\/4 on the unit\u003c\/li\u003e\n\u003cli\u003eOptions (not expanded): T display off, D\/J cable, KA unit-switching display\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eClean air (5 um filtered, no oil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e50-200 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e600 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection nozzle\u003c\/th\u003e\n\u003ctd\u003eSingle-hole dia. 1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eDC24 V +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd\u003eDC30 V, 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP67 equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring\u003c\/th\u003e\n\u003ctd\u003eM12 connector, 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePorts\u003c\/th\u003e\n\u003ctd\u003eSupply Rc1\/4, detection one-touch 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCode format\u003c\/th\u003e\n\u003ctd\u003eUGPS3-\u0026lt;stations\u0026gt;\u0026lt;range\u0026gt;\u0026lt;output\u0026gt;\u0026lt;side\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-024SK-9, p. 1313-1313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1NR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1LL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1ENR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1ENL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1EPR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1EPL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1ELR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-1ELL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 1 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2NR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2LL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2ENR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2ENL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2EPR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2EPL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2ELR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-2ELL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 2 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3NR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3LL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3ENR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3ENL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3EPR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3EPL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3ELR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-3ELL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 3 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4NR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4LL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4ENR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4ENL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4EPR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4EPL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4ELR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-4ELL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 4 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5NR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5LL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5ENR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5ENL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5EPR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5EPL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5ELR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-5ELL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 5 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6NR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6NL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.03-0.4 mm (wide) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6PR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6PL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.03-0.4 mm (wide) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6LR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6LL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.03-0.4 mm (wide) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6ENR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6ENL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.02-0.15 mm (short) | Output: NPN open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6EPR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6EPL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.02-0.15 mm (short) | Output: PNP open collector x2 | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6ELR\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Right (supply right)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUGPS3-6ELL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eStations: 6 | Detection range: 0.02-0.15 mm (short) | Output: IO-Link | Regulator\/valve side: Left (supply left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524178870562,"sku":"UGPS3-1NR","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-ugps3-digital-gap-switch-unit.jpg?v=1791975301","url":"https:\/\/prosourcemro.com\/products\/ckd-ugps3-digital-gap-switch-unit","provider":"ProSource MRO","version":"1.0","type":"link"}