{"product_id":"ckd-wxu-p-water-integrated-unit","title":"CKD WXU-P Water Integrated Unit, 2-Fluid (Water \/ Air Purge)","description":"\u003cp class=\"ps-intro\"\u003eCKD WXU-P 2-fluid water integrated unit uses supply and return units to switch two fluids (e.g. cooling water and purge air) per circuit, for spot welders and similar equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSupply (S) and return (R) units, 2 to 6 stations; inblock left (L) listed, right (R) or both (W) also available\u003c\/li\u003e\n\u003cli\u003eTwo GNAB-based cylinder valves per station: fluid 1 valve standard (S) or high flow (B), each NC (1) or NO (2)\u003c\/li\u003e\n\u003cli\u003eNeedle flow adjustment (N) or none (0); branch ports Rc3\/8 or Rc1\/2\u003c\/li\u003e\n\u003cli\u003eReturn side WFK3000 flow sensor 04\/12\/32; supply side without sensor (00-000)\u003c\/li\u003e\n\u003cli\u003eListed return-side codes use sensor output A0 (DC0-5V); A1-A3, N0-P1 and A*N0..P1 combinations replace the last block, e.g. WXU-P-R-6-L-S11-N-15-12-A0N0\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eWater, hot water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeal\u003c\/th\u003e\n\u003ctd\u003eFKM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e5-50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluids\u003c\/th\u003e\n\u003ctd\u003eWater and air (2 fluids)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIN\/OUT port\u003c\/th\u003e\n\u003ctd\u003eRc1 (inblock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInblock position (listed)\u003c\/th\u003e\n\u003ctd\u003eL (left)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eCKD Korea catalog CB-03-1SK-9, p. 717-734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-S22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-S22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-2-L-B22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-2-L-B22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 2 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-S22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-S22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-3-L-B22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-3-L-B22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 3 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-S22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-S22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-4-L-B22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-4-L-B22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 4 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-S22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-S22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-5-L-B22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-5-L-B22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 5 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-S22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-S22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: Standard, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B11-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B11-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B11-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B11-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B11-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B12-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B12-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B12-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B12-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B12-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NC \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B21-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B21-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B21-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B21-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B21-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NC | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-N-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-N-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-N-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B22-N-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-N-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-N-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-N-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B22-N-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: Flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-0-10-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-0-10-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-0-10-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B22-0-10-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc3\/8 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-0-15-04-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 0.5-4.0 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-0-15-12-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 1.5-12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-R-6-L-B22-0-15-32-A0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Return | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: 4.0-32 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWXU-P-S-6-L-B22-0-15-00-000\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSide: Supply | Stations: 6 | Valves: High flow, fluid1 NO \/ fluid2 NO | Flow adjust \/ branch: No flow adj., Rc1\/2 | Sensor range: No sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"CKD","offers":[{"title":"Default Title","offer_id":67524229497122,"sku":"WXU-P-R-2-L-S11-N-10-04-A0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ckd-wxu-p-water-integrated-unit.jpg?v=1791975279","url":"https:\/\/prosourcemro.com\/products\/ckd-wxu-p-water-integrated-unit","provider":"ProSource MRO","version":"1.0","type":"link"}