{"product_id":"fuji-electric-sz-surge-suppressor-units","title":"Fuji Electric SZ Surge Suppressor Units for SC \/ NEO SC Contactors","description":"\u003cp class=\"ps-intro\"\u003eCoil surge suppressor units (varistor or CR type, with or without LED), main-circuit surge absorbers and transient protector units for New SC and NEO SC contactors.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eVaristor and CR coil surge suppressors\u003c\/li\u003e\n\u003cli\u003eLED operation indicator versions\u003c\/li\u003e\n\u003cli\u003eMain-circuit CR surge absorbers for 3-phase motors (200V)\u003c\/li\u003e\n\u003cli\u003eTransient protector units for AC loads\u003c\/li\u003e\n\u003cli\u003eMount directly on the coil terminals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNew SC \/ NEO SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eOn contactor coil terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003eSeparately sold part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTypes\u003c\/th\u003e\n\u003ctd\u003eVaristor, CR, main-circuit CR, transient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCode format\u003c\/th\u003e\n\u003ctd\u003eSZ- + option code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eFuji Electric New SC \/ NEO SC contactor catalogue, p. 26-27, 42-43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC24-48V | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC100-250V | Applies to: SC-03\/G~5-1\/G, SH-4\/G, 5\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC380-440V | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC24-48V, LED | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC100-240V, LED | Applies to: SC-03\/G~5-1\/G, SH-4\/G, 5\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z31\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC24-48V | Applies to: SC-N1~N3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC100-250V | Applies to: SC-N1\/G~N3\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC380-440V | Applies to: SC-N1~N3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z41\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC24-48V | Applies to: SC-N4, N5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z42\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC\/DC100-250V | Applies to: SC-N4\/G, N5\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z43\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Varistor | Detail: AC380-440V | Applies to: SC-N4, N5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC\/DC24-48V | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC\/DC100-250V | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC\/DC24-48V, LED | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC\/DC100-240V, LED | Applies to: SC-03~5-1, SH-4, 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC24-48V | Applies to: SC-N1~N3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z35\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC100-250V | Applies to: SC-N1~N3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z36\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: DC24-48V | Applies to: SC-N1\/G~N3\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z37\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: DC100-250V | Applies to: SC-N1\/G~N3\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC24-48V | Applies to: SC-N4, N5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: AC100-250V | Applies to: SC-N4, N5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-Z46\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: CR | Detail: DC24-48V | Applies to: SC-N4\/G, N5\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-ZM1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Main circuit CR | Detail: head-on, 0.1-3.7kW | Applies to: SC-03~5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-ZM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Main circuit CR | Detail: head-on, 0.1-15kW | Applies to: SC-N1~N3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-ZM2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Main circuit CR | Detail: side-on, 0.1-3.7kW | Applies to: SC-03~5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-ZM4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Main circuit CR | Detail: side-on, 0.1-15kW | Applies to: SC-N1~N3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-RC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Transient protector | Detail: AC100-127V | Applies to: SC-03~N16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSZ-RC2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Transient protector | Detail: AC200-250V | Applies to: SC-03~N16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Fuji Electric","offers":[{"title":"Default Title","offer_id":67603323453730,"sku":"SZ-Z1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/fuji-electric-sz-surge-suppressor-units.jpg?v=1792986405","url":"https:\/\/prosourcemro.com\/products\/fuji-electric-sz-surge-suppressor-units","provider":"ProSource MRO","version":"1.0","type":"link"}