{"product_id":"ggm-k9i-60f-t-series-60w-three-phase-ac-induction-motor-90mm-4-pole-terminal-box","title":"GGM K9I□60F-T Series 60W Three-phase AC Induction Motor (□90mm, 4-Pole, Terminal Box)","description":"\u003cp class=\"ps-intro\"\u003eGGM K9I□60F series 60W three-phase AC induction motor. □90mm frame, 4-pole, continuous rating, terminal box (metal).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStraight (S) and pinion (P) shaft; 200–440V (50\/60Hz)\u003c\/li\u003e\n\u003cli\u003ePinion-shaft type combines with K9P□ high-power gear heads (matching face\/teeth)\u003c\/li\u003e\n\u003cli\u003eH variant (220\/230V) UL certified (E204632)\u003c\/li\u003e\n\u003cli\u003eNote: 3-phase motors for 380V and over cannot be used with an inverter\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e60W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e□90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eTerminal Box (metal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IS60FT-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IS60FT-T — Straight shaft, 200V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Terminal Box (metal) | Voltage: 200V | Operating Points: 200V\/50Hz: 0.49A, Start 1.35\/13.5N·m·kgf·cm, Rated 0.45\/4.5N·m·kgf·cm, 1300rpm ; 200V\/60Hz: 0.45A, Start 1.05\/10.5N·m·kgf·cm, Rated 0.38\/3.8N·m·kgf·cm, 1550rpm | UL: —\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IP60FT-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IP60FT-T — Pinion (for gear head) shaft, 200V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Terminal Box (metal) | Voltage: 200V | Operating Points: 200V\/50Hz: 0.49A, Start 1.35\/13.5N·m·kgf·cm, Rated 0.45\/4.5N·m·kgf·cm, 1300rpm ; 200V\/60Hz: 0.45A, Start 1.05\/10.5N·m·kgf·cm, Rated 0.38\/3.8N·m·kgf·cm, 1550rpm | UL: —\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IS60FH-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IS60FH-T — Straight shaft, 220\/230V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Terminal Box (metal) | Voltage: 220\/230V | Operating Points: 220V\/50Hz: 0.55A, Start 1.6\/16N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 220V\/60Hz: 0.47A, Start 1.2\/12N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm ; 230V\/50Hz: 0.60A, Start 1.65\/16.5N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 230V\/60Hz: 0.52A, Start 1.3\/13N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: Certified (E204632)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IP60FH-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IP60FH-T — Pinion (for gear head) shaft, 220\/230V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Terminal Box (metal) | Voltage: 220\/230V | Operating Points: 220V\/50Hz: 0.55A, Start 1.6\/16N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 220V\/60Hz: 0.47A, Start 1.2\/12N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm ; 230V\/50Hz: 0.60A, Start 1.65\/16.5N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 230V\/60Hz: 0.52A, Start 1.3\/13N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: Certified (E204632)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IS60FM-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IS60FM-T — Straight shaft, 380V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Terminal Box (metal) | Voltage: 380V | Operating Points: 380V\/50Hz: 0.34A, Start 1.55\/15.5N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 380V\/60Hz: 0.25A, Start 1.19\/11.9N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IP60FM-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IP60FM-T — Pinion (for gear head) shaft, 380V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Terminal Box (metal) | Voltage: 380V | Operating Points: 380V\/50Hz: 0.34A, Start 1.55\/15.5N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 380V\/60Hz: 0.25A, Start 1.19\/11.9N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IS60FV-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IS60FV-T — Straight shaft, 400V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Terminal Box (metal) | Voltage: 400V | Operating Points: 400V\/50Hz: 0.37A, Start 1.85\/18.5N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 400V\/60Hz: 0.28A, Start 1.42\/14.2N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IP60FV-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IP60FV-T — Pinion (for gear head) shaft, 400V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Terminal Box (metal) | Voltage: 400V | Operating Points: 400V\/50Hz: 0.37A, Start 1.85\/18.5N·m·kgf·cm, Rated 0.435\/4.35N·m·kgf·cm, 1350rpm ; 400V\/60Hz: 0.28A, Start 1.42\/14.2N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IS60FQ-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IS60FQ-T — Straight shaft, 415V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Terminal Box (metal) | Voltage: 415V | Operating Points: 415V\/50Hz: 0.26A, Start 1.45\/14.5N·m·kgf·cm, Rated 0.45\/4.5N·m·kgf·cm, 1300rpm ; 415V\/60Hz: 0.21A, Start 1.15\/11.5N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IP60FQ-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IP60FQ-T — Pinion (for gear head) shaft, 415V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Terminal Box (metal) | Voltage: 415V | Operating Points: 415V\/50Hz: 0.26A, Start 1.45\/14.5N·m·kgf·cm, Rated 0.45\/4.5N·m·kgf·cm, 1300rpm ; 415V\/60Hz: 0.21A, Start 1.15\/11.5N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IS60FZ-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IS60FZ-T — Straight shaft, 440V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Straight | Connection: Terminal Box (metal) | Voltage: 440V | Operating Points: 440V\/50Hz: 0.28A, Start 1.6\/16N·m·kgf·cm, Rated 0.45\/4.5N·m·kgf·cm, 1300rpm ; 440V\/60Hz: 0.23A, Start 1.25\/12.5N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK9IP60FZ-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGGM 60W three-phase AC induction motor K9IP60FZ-T — Pinion (for gear head) shaft, 440V, Terminal Box (metal) | Output: 60W | Poles: 4 | Phase: Three-phase | Frame: □90mm | Shaft: Pinion (for gear head) | Connection: Terminal Box (metal) | Voltage: 440V | Operating Points: 440V\/50Hz: 0.28A, Start 1.6\/16N·m·kgf·cm, Rated 0.45\/4.5N·m·kgf·cm, 1300rpm ; 440V\/60Hz: 0.23A, Start 1.25\/12.5N·m·kgf·cm, Rated 0.37\/3.7N·m·kgf·cm, 1600rpm | UL: — | Caution: 380V+ 3-phase: not for inverter use (winding insulation damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"GGM","offers":[{"title":"Default Title","offer_id":67396564222242,"sku":"GGM-K9I60F-3P-T","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/002-216_ee500f55-670e-4f62-98ce-f24cf578ecf1.png?v=1790661109","url":"https:\/\/prosourcemro.com\/products\/ggm-k9i-60f-t-series-60w-three-phase-ac-induction-motor-90mm-4-pole-terminal-box","provider":"ProSource MRO","version":"1.0","type":"link"}