{"product_id":"kyongbo-electric-digital-multi-circuit-earth-leakage-detector-and-relay-gd-l03-gd-l05","title":"Kyongbo Electric Digital Multi-Circuit Earth Leakage Detector and Relay GD-L03 \/ GD-L05","description":"\u003cp class=\"ps-intro\"\u003eThis fully digital arithmetic earth leakage detector detects leakage current on lines up to 600 V through ZCTs and raises an alarm, with relay (R type) versions providing trip outputs.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003e6, 8, 10, 12 and 16 circuit versions\u003c\/li\u003e\n\u003cli\u003e7-segment digital display of measured value and faulted line\u003c\/li\u003e\n\u003cli\u003eIndividual operating current and time setting per circuit\u003c\/li\u003e\n\u003cli\u003eHarmonic filtering, operates on fundamental wave\u003c\/li\u003e\n\u003cli\u003eApplied standard KOFEIS 0308\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStructure\u003c\/th\u003e\n\u003ctd\u003eFlush mounted, non-drawout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Power Supply\u003c\/th\u003e\n\u003ctd\u003eAC\/DC 110-220 V (free voltage), 20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz (50 Hz option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operating Current\u003c\/th\u003e\n\u003ctd\u003e0.2 - 0.5 - 1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine Voltage\u003c\/th\u003e\n\u003ctd\u003eAC 600 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Contacts (Ta, Tc)\u003c\/th\u003e\n\u003ctd\u003e10 A at AC 120 V, 10 A at DC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePanel Cutout\u003c\/th\u003e\n\u003ctd\u003e122 x 164 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e138 x 200 mm front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eapprox. 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD8-L03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 8 | Type: ELD (alarm) | Communication: RS-485 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD16-L03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 16 | Type: ELD (alarm) | Communication: RS-485 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD8-L03R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 8 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V | Communication: RS-485 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD16-L03R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 16 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V | Communication: RS-485 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD6-L05A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 6 | Type: ELD (alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD8-L05A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 8 | Type: ELD (alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD10-L05A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 10 | Type: ELD (alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD12-L05A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 12 | Type: ELD (alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD16-L05A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 16 | Type: ELD (alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD6-L05R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 6 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD8-L05R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 8 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD10-L05R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 10 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD12-L05R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 12 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGD16-L05R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuits: 16 | Type: ELR (with trip outputs) | Trip Output: 1a x circuits, 5 A at AC 250 V \/ 5 A at DC 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Kyongbo Electric","offers":[{"title":"Default Title","offer_id":67495226147106,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/kyongbo-electric-digital-multi-circuit-earth-leakage-detector-and-relay-gd-l03-gd-l05-1.jpg?v=1791599303","url":"https:\/\/prosourcemro.com\/products\/kyongbo-electric-digital-multi-circuit-earth-leakage-detector-and-relay-gd-l03-gd-l05","provider":"ProSource MRO","version":"1.0","type":"link"}