{"product_id":"kyongbo-electric-induction-over-current-relay-gco-c-normally-open-contact","title":"Kyongbo Electric Induction Over Current Relay GCO-C (Normally Open Contact)","description":"\u003cp class=\"ps-intro\"\u003eThe GCO-C relay operates with time delay on current exceeding a given value to trip a DC-controlled circuit breaker, for short circuit protection of power lines and overload protection of AC equipment.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eInverse and very inverse time characteristics\u003c\/li\u003e\n\u003cli\u003eTap setting by plug position, time lever setting\u003c\/li\u003e\n\u003cli\u003eIndicating contact switch (ICS) unit\u003c\/li\u003e\n\u003cli\u003eICS coil options: DC current 0.2\/2.0 A, 0.5\/2.0 A, 1.0 A; DC voltage 24\/110\/125 V; AC current 0.5\/1.0\/2.0 A; AC voltage 110\/220 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz (standard), 50 Hz (option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Color\u003c\/th\u003e\n\u003ctd\u003eMunsell N1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅢ4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Inverse | Rating: 5 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅢ3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Inverse | Rating: 5 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅢ2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Inverse | Rating: 5 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅡ4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Very inverse | Rating: 5 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅡ3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Very inverse | Rating: 5 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅡ2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Very inverse | Rating: 5 A | ICS Unit: DC 1.0 A | Case: Non-drawout | Weight: approx. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅢD4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Inverse | Rating: 5 A | ICS Unit: DC 0.5\/2.0 A | Case: Drawout | Weight: approx. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅢD3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Inverse | Rating: 5 A | ICS Unit: DC 0.5\/2.0 A | Case: Drawout | Weight: approx. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅢD2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Inverse | Rating: 5 A | ICS Unit: DC 0.5\/2.0 A | Case: Drawout | Weight: approx. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅡD4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 4-12 A | Taps: 4, 5, 6, 7, 8, 10, 12 A | Characteristic: Very inverse | Rating: 5 A | ICS Unit: DC 0.5\/2.0 A | Case: Drawout | Weight: approx. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅡD3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 3-8 A | Taps: 3, 4, 5, 6, 8 A | Characteristic: Very inverse | Rating: 5 A | ICS Unit: DC 0.5\/2.0 A | Case: Drawout | Weight: approx. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGCO-CⅡD2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTap Range: 2-6 A | Taps: 2, 3, 4, 5, 6 A | Characteristic: Very inverse | Rating: 5 A | ICS Unit: DC 0.5\/2.0 A | Case: Drawout | Weight: approx. 4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Kyongbo Electric","offers":[{"title":"Default Title","offer_id":67495225524514,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/kyongbo-electric-induction-over-current-relay-gco-c-normally-open-contact-1.jpg?v=1791599302","url":"https:\/\/prosourcemro.com\/products\/kyongbo-electric-induction-over-current-relay-gco-c-normally-open-contact","provider":"ProSource MRO","version":"1.0","type":"link"}