{"product_id":"kyongbo-electric-power-factor-meter-p1-p4-transducer-type","title":"Kyongbo Electric Power Factor Meter P1-P4 (Transducer Type)","description":"\u003cp class=\"ps-intro\"\u003eTransducer type panel power factor meter for balanced and unbalanced loads.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStandard scale LEAD 0.5 - 1 - LAG 0.5\u003c\/li\u003e\n\u003cli\u003eAccuracy guaranteed above 30% of rated current\u003c\/li\u003e\n\u003cli\u003eInternal (WA-TP) or external transducer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Color\u003c\/th\u003e\n\u003ctd\u003eBlack (Munsell N1.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eSee catalog pages 324-325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Input\u003c\/th\u003e\n\u003ctd\u003e5 A or 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd\u003e5.0% (of 90 electrical degrees)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurden\u003c\/th\u003e\n\u003ctd\u003eVoltage 0.5 VA, current 0.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-P1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Square | System: 1P 2W | Voltage: 110 or 220 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSB-P1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 100 x 84 mm | Scale Form: Square | System: 1P 2W | Voltage: 110 or 220 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA-P1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 120 x 100 mm | Scale Form: Square | System: 1P 2W | Voltage: 110 or 220 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWB-P1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Wide angle | System: 1P 2W | Voltage: 110 or 220 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-P1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 1P 2W | Voltage: 110 or 220 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-TP1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 1P 2W | Voltage: 110 or 220 V | Transducer: Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-P2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Square | System: 1P 3W | Voltage: 110 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSB-P2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 100 x 84 mm | Scale Form: Square | System: 1P 3W | Voltage: 110 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA-P2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 120 x 100 mm | Scale Form: Square | System: 1P 3W | Voltage: 110 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWB-P2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Wide angle | System: 1P 3W | Voltage: 110 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-P2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 1P 3W | Voltage: 110 V | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-TP2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 1P 3W | Voltage: 110 V | Transducer: Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-P3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Square | System: 3P 3W | Voltage: 110 or 220 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-UP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Square | System: 3P 3W | Voltage: 110 or 220 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSB-P3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 100 x 84 mm | Scale Form: Square | System: 3P 3W | Voltage: 110 or 220 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSB-UP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 100 x 84 mm | Scale Form: Square | System: 3P 3W | Voltage: 110 or 220 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA-P3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 120 x 100 mm | Scale Form: Square | System: 3P 3W | Voltage: 110 or 220 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA-UP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 120 x 100 mm | Scale Form: Square | System: 3P 3W | Voltage: 110 or 220 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWB-P3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Wide angle | System: 3P 3W | Voltage: 110 or 220 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWB-UP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Wide angle | System: 3P 3W | Voltage: 110 or 220 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-P3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 3W | Voltage: 110 or 220 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-UP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 3W | Voltage: 110 or 220 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-TP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 3W | Voltage: 110 or 220 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-UTP3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 3W | Voltage: 110 or 220 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Square | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-UP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Square | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSB-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 100 x 84 mm | Scale Form: Square | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSB-UP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 100 x 84 mm | Scale Form: Square | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 120 x 100 mm | Scale Form: Square | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA-UP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 120 x 100 mm | Scale Form: Square | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWB-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Wide angle | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWB-UP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 80 x 80 mm | Scale Form: Wide angle | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-P4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-UP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: External\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-TP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Balanced | Frequency: 50\/60 Hz | Transducer: Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWA-UTP4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: 110 x 110 mm | Scale Form: Wide angle | System: 3P 4W | Voltage: 190\/sqrt3 or 380\/sqrt3 V | Load: Unbalanced | Frequency: 50 or 60 Hz | Transducer: Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Kyongbo Electric","offers":[{"title":"Default Title","offer_id":67495226671394,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/kyongbo-electric-power-factor-meter-p1-p4-transducer-type-1.jpg?v=1791599304","url":"https:\/\/prosourcemro.com\/products\/kyongbo-electric-power-factor-meter-p1-p4-transducer-type","provider":"ProSource MRO","version":"1.0","type":"link"}