{"product_id":"ls-electric-abs100fb-beyond-x-industrial-distribution-panel-mcb-rcbo-s-type-hydraulic-magnetic-standard-high-breaking-100af-mcb-10ka-220v-ac-5ka-460v-ac-60100a","title":"LS Electric ABS100Fb Beyond X Industrial Distribution Panel MCB\/RCBO (S-type Hydraulic-Magnetic (Standard, High breaking), 100AF MCB, 10kA @ 220V AC \/ 5kA @ 460V AC, 60~100A)","description":"\u003cp class=\"ps-intro\"\u003eLS ELECTRIC Beyond X Industrial Distribution Panel MCB\/RCBO ABS100Fb family. | Application: Industrial distribution panel (MCB). | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Rated current (In): 60A, 75A, 100A | Pole: 2P \/ 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | 6 variants — see RFQ table for specific MPN.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e100AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eS-type Hydraulic-Magnetic (Standard, High breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icn\u003c\/th\u003e\n\u003ctd\u003e10kA @ 220V AC \/ 5kA @ 460V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIcs\u003c\/th\u003e\n\u003ctd\u003e100% Icn\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip method\u003c\/th\u003e\n\u003ctd\u003eHydraulic-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip curve\u003c\/th\u003e\n\u003ctd\u003e(7~15)×In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUimp\u003c\/th\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eScrew or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003eAC 220\/460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eKSC 8321 \/ IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eIndustrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS102Fb\/60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Fb ABS100Fb — ABS102Fb 60A 2P (MCB) | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Rated current (In): 60A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | Application: Industrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS102Fb\/75\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Fb ABS100Fb — ABS102Fb 75A 2P (MCB) | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Rated current (In): 75A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | Application: Industrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS102Fb\/100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Fb ABS100Fb — ABS102Fb 100A 2P (MCB) | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Rated current (In): 100A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | Application: Industrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS103Fb\/60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Fb ABS100Fb — ABS103Fb 60A 3P (MCB) | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Rated current (In): 60A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | Application: Industrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS103Fb\/75\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Fb ABS100Fb — ABS103Fb 75A 3P (MCB) | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Rated current (In): 75A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | Application: Industrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABS103Fb\/100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABS Fb ABS100Fb — ABS103Fb 100A 3P (MCB) | Frame: 100AF | Type: S-type Hydraulic-Magnetic (Standard, High breaking) | Rated current (In): 100A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC \/ 5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220\/460V | Standard: KSC 8321 \/ IEC 60947-2 | Application: Industrial distribution panel (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67396594467106,"sku":"LSE-ABS100Fb","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-1506_db70014e-f757-49a4-86aa-42eb259ed674.png?v=1790661825","url":"https:\/\/prosourcemro.com\/products\/ls-electric-abs100fb-beyond-x-industrial-distribution-panel-mcb-rcbo-s-type-hydraulic-magnetic-standard-high-breaking-100af-mcb-10ka-220v-ac-5ka-460v-ac-60100a","provider":"ProSource MRO","version":"1.0","type":"link"}