{"product_id":"ls-electric-gmp22-gmp40-electronic-motor-protection-relay","title":"LS Electric GMP22\/GMP40 Electronic Motor Protection Relay (0.3-40 A)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric GMP22 and GMP40 electronic motor protection relays (EMPR) for 0.3-40 A motors, in direct-connect (pin), screw-terminal and tunnel (feed-through) versions.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDirect-pin versions mount directly on Metasol MC-9b to MC-22b (GMP22) or MC-32a\/40a (GMP40); order with the Sol suffix\u003c\/li\u003e\n\u003cli\u003eOvercurrent, locked-rotor and phase-loss protection; 3CT models add unbalance, R models add phase reversal\u003c\/li\u003e\n\u003cli\u003eInverse-time characteristic (0-30 s) as standard; PD models offer definite-time characteristic\u003c\/li\u003e\n\u003cli\u003ePA models provide automatic reset after an overcurrent trip\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based with red LED trip indication; DIN rail or screw mounting for screw\/tunnel types\u003c\/li\u003e\n\u003cli\u003eUsable on inverter secondary side (except 3PR\/3TR\/3SR)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eGMP (Beyond X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrames\u003c\/th\u003e\n\u003ctd\u003eGMP22 (0.3-22 A), GMP40 (4-40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eCurrent +\/-5%, time +\/-5% (or +\/-0.5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contact rating\u003c\/th\u003e\n\u003ctd\u003e5 A \/ 250 V AC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation resistance\u003c\/th\u003e\n\u003ctd\u003e100 MOhm min. at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndication\u003c\/th\u003e\n\u003ctd\u003eRed LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL508, IEC 60947-1; UL, CE (except PD\/PA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric EMPR Series catalog C15031-15 (2025-11), p. 10, 13-18, 134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)1.5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (Sol, Metasol direct) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (Sol, Metasol direct) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)22ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (Sol, Metasol direct) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)1.5A[N]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, N type (fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)5A[N]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, N type (fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)22A[N]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, N type (fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)1.5A[R]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, R type (non-fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)5A[R]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, R type (non-fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1c)22A[R]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, R type (non-fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)1.5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (Sol, Metasol direct) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (Sol, Metasol direct) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)22ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (Sol, Metasol direct) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)1.5A[N]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, N type (fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)5A[N]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, N type (fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)22A[N]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, N type (fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)1.5A[R]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, R type (non-fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)5A[R]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, R type (non-fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PD(1c)22A[R]\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c, R type (non-fail-safe) | Control voltage: AC 110 V or 220 V (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1a1b)1.5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1a1b)5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2P(1a1b)22ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PA(1a1b)1.5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, lock, phase loss; auto reset | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PA(1a1b)5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, lock, phase loss; auto reset | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2PA(1a1b)22ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, lock, phase loss; auto reset | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3P1.5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3P5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3P22ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3PR1.5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3PR5ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3PR22ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2S1.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2S5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2S22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3S1.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3S5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3S22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3SR1.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3SR5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3SR22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2T1.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2T5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-2T22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3T1.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3T5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3T22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3TR1.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 0.3-1.5 A (0.12-0.55 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3TR5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 1-5 A (0.37-2.2 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP22-3TR22A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 4.4-22 A (2.2-11 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2P20ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2P40ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2PA20ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, lock, phase loss; auto reset | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2PA40ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, lock, phase loss; auto reset | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2PD20ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2PD40ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Definite (D 0-60 s, O 5 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3P20ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3P40ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3PR20ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3PR40ASol\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Direct pin (Metasol MC) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2S20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2S40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3S20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3S40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3SR20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3SR40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Screw terminal | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2T20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-2T40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3T20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3T40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3TR20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 4-20 A (2.2-7.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP40-3TR40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConnection: Tunnel (feed-through) | Setting range: 8-40 A (4-18.5 kW at 400V) | Time characteristic: Inverse (0-30 s) | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521969553698,"sku":"GMP22-2P(1c)1.5ASol","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-gmp22-gmp40-electronic-motor-protection-relay.jpg?v=1791954613","url":"https:\/\/prosourcemro.com\/products\/ls-electric-gmp22-gmp40-electronic-motor-protection-relay","provider":"ProSource MRO","version":"1.0","type":"link"}