{"product_id":"ls-electric-gmp60-gmp80-electronic-motor-protection-relay","title":"LS Electric GMP60\/GMP80 Electronic Motor Protection Relay (0.5-80 A)","description":"\u003cp class=\"ps-intro\"\u003eLS Electric GMP60 tunnel-type and GMP80 screw-terminal electronic motor protection relays for 0.5-80 A motors, including 3-phase current display and ground-fault versions.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eGMP60T\/TE\/TA: compact 2CT tunnel type, definite-time, 1c contact; usable above 60 A with external CTs\u003c\/li\u003e\n\u003cli\u003eGMP60-TD\/TDa: 7-segment 3-phase current display, DIP-switch setting 0.5-60 A, trip cause memory\u003c\/li\u003e\n\u003cli\u003eGMP60-3T\/3TR: 3CT with unbalance and (R) phase reversal protection\u003c\/li\u003e\n\u003cli\u003eGMP60-3TZ (zero-sequence, external ZCT) and 3TN (residual current) ground-fault protection models\u003c\/li\u003e\n\u003cli\u003eGMP80: 16-80 A screw-terminal inverse-time relay in 2CT, 2CT auto reset and 3CT versions\u003c\/li\u003e\n\u003cli\u003eDIN rail or screw mounting; usable on inverter secondary side (except reversal\/ZCT models)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eGMP (Beyond X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrames\u003c\/th\u003e\n\u003ctd\u003eGMP60 (0.5-60 A), GMP80 (16-80 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eCurrent +\/-5%, time +\/-5% (or +\/-0.5 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contact rating\u003c\/th\u003e\n\u003ctd\u003e5 A \/ 250 V AC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation resistance\u003c\/th\u003e\n\u003ctd\u003e100 MOhm min. at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eZCT (3TZ models)\u003c\/th\u003e\n\u003ctd\u003eEMPR ZCT 100 mA \/ 40-55 mV (LZR series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-1 (GMP80 also UL508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eLS Electric EMPR Series catalog C15031-15 (2025-11), p. 10, 19-27, 134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60T6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60T standard | Setting range: 0.5-6 A (0.18-2.2 kW at 400V) | Time characteristic: Definite (D 0-30 s, O 0-15 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 24\/48\/110\/220\/380 V or 180-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60T30A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60T standard | Setting range: 3-30 A (1.5-15 kW at 400V) | Time characteristic: Definite (D 0-30 s, O 0-15 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 24\/48\/110\/220\/380 V or 180-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60T60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60T standard | Setting range: 5-60 A (3-30 kW at 400V) | Time characteristic: Definite (D 0-30 s, O 0-15 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 24\/48\/110\/220\/380 V or 180-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60TE6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60TE economy | Setting range: 0.5-6 A (0.18-2.2 kW at 400V) | Time characteristic: Definite (D 0-30 s, O 5 s fixed) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 24\/48\/110\/220\/380 V or 180-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60TE30A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60TE economy | Setting range: 3-30 A (1.5-15 kW at 400V) | Time characteristic: Definite (D 0-30 s, O 5 s fixed) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 24\/48\/110\/220\/380 V or 180-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60TE60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60TE economy | Setting range: 5-60 A (3-30 kW at 400V) | Time characteristic: Definite (D 0-30 s, O 5 s fixed) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 24\/48\/110\/220\/380 V or 180-480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60TA6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60TA auto reset | Setting range: 0.5-6 A (0.18-2.2 kW at 400V) | Time characteristic: Definite (O 5 s); auto reset 0-120 s | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 110 V or 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60TA30A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60TA auto reset | Setting range: 3-30 A (1.5-15 kW at 400V) | Time characteristic: Definite (O 5 s); auto reset 0-120 s | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 110 V or 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60TA60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60TA auto reset | Setting range: 5-60 A (3-30 kW at 400V) | Time characteristic: Definite (O 5 s); auto reset 0-120 s | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 1SPDT 1c (N type) | Control voltage: AC 110 V or 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-TD6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-TD 3-phase display | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 1-60 s, O 0.5-30 s) | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 110 V or 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-TDa6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-TDa display, auto reset | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 1-60 s); auto reset 1-20 min | Protection: 2CT: OC, lock, phase loss, undercurrent | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 110 V or 220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-3T6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-3T 3CT tunnel | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 0.2-60 s, O 0.2-15 s) | Protection: 3CT: OC, lock, loss, unbal. | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-3TR6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-3T 3CT tunnel R | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 0.2-60 s, O 0.2-15 s) | Protection: 3CT: OC, lock, loss, unbal., reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-3TZ6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-3TZ ground fault (ZCT) | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 0.2-60 s, O 3 s) | Protection: OC, lock, loss, unbal., GF 0.1-2.5A | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-3TZR6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-3TZ ground fault (ZCT) R | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 0.2-60 s, O 3 s) | Protection: OC, lock, loss, unbal., GF 0.1-2.5A+rev | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-3TN6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-3TN ground fault (residual) | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 0.2-60 s, O 3 s) | Protection: OC, lock, loss, unbal., GF 0.5-6A | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP60-3TNR6\/60A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP60-3TN ground fault (residual) R | Setting range: 0.5-60 A (0.18-30 kW at 400V) | Time characteristic: Definite (D 0.2-60 s, O 3 s) | Protection: OC, lock, loss, unbal., GF 0.5-6A+rev | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP80-2S80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP80 screw terminal | Setting range: 16-80 A (11-45 kW at 400V) | Time characteristic: Inverse | Protection: 2CT: OC, locked rotor, phase loss | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP80-2SA80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP80 screw terminal | Setting range: 16-80 A (11-45 kW at 400V) | Time characteristic: Inverse | Protection: 2CT: OC, lock, phase loss; auto reset | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP80-3S80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP80 screw terminal | Setting range: 16-80 A (11-45 kW at 400V) | Time characteristic: Inverse | Protection: 3CT: OC, lock, phase loss, unbalance | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGMP80-3SR80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: GMP80 screw terminal | Setting range: 16-80 A (11-45 kW at 400V) | Time characteristic: Inverse | Protection: 3CT: + unbalance, phase reversal | Auxiliary contact: 2SPST 1a1b | Control voltage: AC 100-260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"LS Electric","offers":[{"title":"Default Title","offer_id":67521969619234,"sku":"GMP60T6A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/ls-electric-gmp60-gmp80-electronic-motor-protection-relay.jpg?v=1791954613","url":"https:\/\/prosourcemro.com\/products\/ls-electric-gmp60-gmp80-electronic-motor-protection-relay","provider":"ProSource MRO","version":"1.0","type":"link"}